Specifications
Brand Name :
Shenglin
Model Number :
SL-ZKW Series
Certification :
CE
Place of Origin :
China
MOQ :
1
Price :
4999~30000USD/unit
Payment Terms :
T/T, Western Union
Supply Ability :
100 Units Per Month
Delivery Time :
35~40days
Packaging Details :
Plywood wooden box or pallet
Type :
Chilled water type
Air cooled or water cooled :
Air cooled
Heater type :
Steam or water coil
Structure type :
Cabinet/ ceiling / vertical / horizontal type
Fan type :
Direct drive motor or belt-driven
Application :
hotels, theaters, shopping malls, office buildings
Air volume :
3000~50000m³/h
Optional installation accessories :
Air valve, air duct or air grill
Description
Package Type Hygienic Air Handling Units Horizontal Chilled Water Type
Feature:
1, Complying with above China Standard, which is from ARI standard. ISO9001 and ISO14001 qualified.
2, Choose best materials, main components are from China top brand or imported.
3, The modular casing design, easy interchanging each other. easy install,easy transport,easy maintaince.
4, Unique no-cold-bridge design, improve the insulation and air tightness, total air leak rate ≤2.5%;
5, With dynamic balanced double inlet Centrifugal fan, with good air dynamic features, and accurate working, high efficiency, low vibration, low noise etc.
6, High efficient heat exchanger coil, ensure to provide the enough cooling capacity to the unit. And also high efficient breakwater panel is provided if required, water flow in coil ≤3×10-4kg/kg
7, Strong structure, good looking and permanent color.
8, Reasonable inside structure, with the suitable space for maintenance and cleaning.
9, Casing sheet: Provide double-skin construction constructing Sandwich type comprising 0.5mm thick galvanized internal and external skins and with 30mm thick polystyrene insulation of minimum 45kg/m3 density. Good airproof material is use between the casing and the frame to reduce the rate of the air leak.
Technical Data:
Chilled Water Air Handing Unit Spec. Table No. 1
Model SL-ZKW- 20 40 60 80 100 150 200 250 300
Air volume(m³/h) 2000 4000 6000 8000 10000 15000 20000 25000 30000
Outlet air pressure(pa) 300 300 400 500 500 600 750 750 750
Supply fan capacity(kw) 1.1 1.5 2.2 4 5.5 11 15 15 18.5
Cooling 4 Rows Return air(kw) 12.2 23.9 35.9 48 60 90 120 150 179
water flow(m³/h) 2.2 4.2 6.1 8.2 10.5 15.3 20.4 23.8 28.2
all fresh air(kw) 22 43.8 62 90 112 156 210 265 310
water flow(m³/h) 3.8 7.7 11 15.5 19.2 27.3 36.5 45.8 55
pipe diameter (DN) 25 32 40 40 40 50 65 65 80
6 Rows Return air(kw) 17 30.1 45.2 60 75 113 151 188 210
water flow(m³/h) 2.8 5.3 7.7 10.5 13.6 19.2 25.5 30.2 36
all fresh air(kw) 30.5 58 88 118 150 200 288 355 420
water flow(m³/h) 5.1 10 15.2 20.2 26.2 35.5 49 70 72.5
pipe diameter (DN) 32 32 40 40 50 65 65 80 80
8 Rows Return air(kw) 18.3 35.2 53 70 90 132 176 220 264
water flow(m³/h) 3.2 6.2 8.9 12.2 16.2 22.2 30.2 37.2 44.2
all fresh air(kw) 34.8 70 101 138 178 245 332 410 500
water flow(m³/h) 5.8 12 17.5 23.5 30.8 42.5 57.1 71 85
pipe diameter (DN) 32 32 40 40 50 65 65 80 80
Heating 2 Rows Return air(kw) 20 42 60 84 108 150 200 250 300
water flow(m³/h) 0.8 1.9 2.6 3.7 4.6 6.5 8.7 11 13
all fresh air(kw) 18 38 54 70 100 125 180 210 280
water flow(m³/h) 0.8 1.7 2.4 3.2 4.5 5.5 7.8 10 12
pipe diameter (DN) 25 32 40 40 40 40 50 50 65
4 Rows Return air(kw) 28 56 80 110 140 200 250 320 380
water flow(m³/h) 1.2 2.4 3.5 4.8 6.3 9 11 13.5 18.2
all fresh air(kw) 32 62 90 125 150 220 300 380 450
water flow(m³/h) 1.5 2.7 3.8 5.4 6.8 9.5 13.5 16.2 19.5
pipe diameter (DN) 32 32 40 40 40 50 50 65 65
Function section
outside dimension
Mixing section Length(mm) 500 500 500 550 600 800 800 800 800
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Pre-filter section Length(mm) 100 100 100 100 100 100 100 100 100
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Medium efficiency filter section Length(mm) 500 500 500 500 500 500 500 500 500
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Cooling coil section Length(mm) 600 600 700 700 700 800 800 1000 1000
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Heating section Length(mm) 300 300 300 400 400 400 400 400 400
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Humidifying section Length(mm) 400 400 400 400 400 400 400 400 400
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Fan section Length(mm) 500 500 900 400 1100 1400 1600 1700 1850
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Current balance section Length(mm) 400 400 500 900 500 600 600 600 700
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Sound deadening section Length(mm) 800 800 800 500 800 1000 1000 1000 100
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Air outlet section Length(mm) 400 400 400 800 500 600 600 800 800
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
1. Cooling condition: supply and return water temp7/12℃,
indoor dry bulb/ wet bulb temp35/28℃, fresh air dry bulb/ wet bulb temp35/28℃

2. Heating condition conditions: supply and return water temp60/50℃,
indoor dry bulb/ wet bulb temp20/ -℃, fresh air dry bulb/ wet bulb temp7/6℃

3. The air volume, residual pressure and power in the table are standard parameters,
and are able to be customized

4. Heater, humidifier and heat recovery device are optional, which can be configured as spacific form according to customer's requirements

5. G4 filter is adopted as the unit standard, which can be configured as other form according to customer's requirements

6. The length and size are determined by the functional sections. Please consult us for details.

Application:

The units are widely used in the air system of many inductries like mechanical ,electronic, textile,medical,chemical,energy and foo inductries ,etc. the units are also ideal solution for restaurants, office buildings,hospitals,theaters,supermarkets and palaestra.

Send your message to this supplier
Send Now

Package Type Hygienic Air Handling Units Horizontal Chilled Water Type

Ask Latest Price
Brand Name :
Shenglin
Model Number :
SL-ZKW Series
Certification :
CE
Place of Origin :
China
MOQ :
1
Price :
4999~30000USD/unit
Contact Supplier
Package Type Hygienic Air Handling Units Horizontal Chilled Water Type
Package Type Hygienic Air Handling Units Horizontal Chilled Water Type

Shanghai Shenglin M&E Technology Co., Ltd.

Active Member
5 Years
shanghai, shanghai
Since 2009
Business Type :
Manufacturer
Employee Number :
>100
Certification Level :
Active Member
Contact Supplier
Submit Requirement