Specifications
Brand Name :
Shenglin
Model Number :
H*FD Series Double rows fans
Certification :
CE and RoHs
Place of Origin :
China
MOQ :
1
Price :
6000~49005 USD per unit
Payment Terms :
T/T, Western Union
Supply Ability :
100 units per month
Delivery Time :
30~35days
Packaging Details :
Stretch film add pallet for container loading
Tube material :
Copper Or stainless steel
Fin material :
Aluminum fin or stainless steel fin
Frame material :
Galvanized steel plate or stainless steel or aluminum
Power supply :
380V/3P/50Hz or 380V/3P/60Hz
Fan brand :
Optional for Chinese and imported brand
Options A :
Adiabatic wet pad or spray water system
Options B :
OEM, ODM
Mouting type :
Floor standing
Cooling method :
Immersion Cooling
Description

Dielectric Fluids V Type Dry Cooler For Datacentre Immersion Cooling System

Why immerse?

  1. Silent Operations - Whether it’s single or two-phase immersion cooling, liquid cooling keeps your hardware submerged in a dielectric fluid of some type. More importantly, that will eliminates the noisy fans, which should be running throughout day and night in condition of air-based cooling and consume roughly 25-30% in additional power required to keep compute equipment on-line.
  2. Reduced PUE - Power usage effectiveness (PUE) is the ratio of a data center’s total facility energy to its total IT equipment (ITE) energy.Legacy or underside air-cooled techniques can struggle to maintain in the 1.8 to 2.4 range. Modern, purpose-built data centers have achieved significant PUE reductions using air-cooled chillers with closed-loop systems, often hitting a PUE of 1.3-1.5.With immersion cooling, PUE consistently stays under 1.3, drastically reducing a facility’s energy load.
  3. Cost Savings - Cooling accounts for a large part of operating expenses. A facility that houses thousands of servers is also expected to run 24/7, 365 days a year. In traditional air cooling, a large number of fans, HVAC and CRAC systems contribute a lot to the electricity bill. However, when servers are submerged in thermally conductive cooling solutions, electricity usage is reduced by more than 95%, which no one can refuse.

Introduction of two-phase liquid cooling:

The cooling liquid undergoes a phase change in the process of circulating heat dissipation. The cooling liquid takes away the heat from the server and then undergoes a phase change gasification. The gaseous cooling liquid is condensed by the condenser and becomes liquid again and returns to the liquid cooling tank; the cooling liquid can use 3M electronics The boiling point of the coolant FC-72 and FC-72 is above 50℃. In this case, the temperature of the water in the condensing coil does not need to be too low. The use of a dry cooler can meet the heat exchange requirements and take away the heat. The two-phase liquid cooling has a high heat transfer efficiency due to the phase change of the electronic cooling liquid. The disadvantage is that during this phase change, the electronic fluorinated liquid will escape during the vaporization process, so there is a certain degree of tightness of the container. However, it should not be too sealed to prevent the cooling system from being interrupted and the cylinder explosion event, so certain safety facilities need to be set up.

Dielectric Fluids V Type Datacentre Immersion Cooling System

Features

  • Our range of Dry Air Coolers and Radiators are designed for commercial and industrial fluid cooling applications.
  • We offer a wide range of options to provide the most cost-effective solution for your cooling requirement.
  • Standard arrangements include flat-bed vertical or horizontal airflow with V configurations to offer the smallest footprint.
  • Whether your application is cooling water / glycol for water cooled chillers, injection moulding machines, furnace equipment, CHP Engine Cooling or any other process. One or more of our units can be selected to provide the most cost-effective solution to suit your space and noise requirement.
  • Energy saving free cooling is possible for much of the year for many applications.

Why choose us:

  1. We can help buyers design specific products or produce products according to buyers' design
  2. We can print logo according to buyers' requirement
  3. We has exported to many countries,such as Singapore, Philippines, Vietnam, Argentina, Peru, Mongolia, Hong Kong, UAE,Russia, Poland etc.
  4. Design term: We have professional design team.
  5. Professional factory: We are manufacturer, specializing in manufacturing heat exchangers for over 16years, competitive price with good quality.
  6. Rapid response to your needs: We will reply within 24 hours after receiving you letter. If you have urgent thing, welcome to call us.
  7. The Most Efficient Service, Best Quality and Excellent Reputation.

Technical Paraments

Flat series — Double rows fans

H*FD*91 Fan Dim
mm
* H*FD491 H*FD691 H*FD89 H*FD1091 H*FD1291 H*FD1491 H*FD1691 H*FD1891
Rated Capacities (kW) Heat Exchange Surface (㎡)
Fluid Coolers 910 D 237kW-1632kW 454㎡-4903㎡ (Water/Ta25℃/Tin40℃/Tout35℃)
Freon Condensers 910 F 285kW-1632kW 454㎡-4903㎡ (R404A/Ta35℃/Tk50℃)
Ammonia Condensers 910 A 151kW-1709kW 263㎡-5696㎡ (NH3/Ta35℃/Tk50℃)
Gas Coolers 910 G 156kW-1929kW 358㎡-3859㎡ ( CO2/Tair32℃/Tin113℃/P94Bar/Tout34℃)
Oil Coolers 910 O 174kW-2212kW 454㎡-4903㎡ (OIL ISO VG 46/Ta35℃/Tin85℃/Tout60℃)
Fan Model 910 EC W3G910KU2503 (2.55kW) or FN091-ZIQ.GL.V5P1 (3.2kW)
910 AC W6D910GB0101 (2.02kW) or FN091-SDS.6N.V7P2 (1.85kW)
No of Fans 4 6 8 10 12 14 16 18
Overall Dimensions 910 Lenth-1 3480 4980 6480 7980 9480 10980 12480 13980
Lenth-2 4080 5880 7680 9480 11280 13080 14880 16680
Width 2265
Height 1740 (Including 800Leg)

Dielectric Fluids V Type Datacentre Immersion Cooling System

Dielectric Fluids V Type Datacentre Immersion Cooling System

Options

Coil design refrigerant: water, oil, glycol Multiple circuits
Sub-cooling circuits Stainless steel or aluminum casing
Coated aluminum or copper fins Explosion proof motor
Customized fin spacing

Reference:

For data center cooling Country: Mongolia
Application: match with precision air conditioner
Cooling capacity: 17.6kW
Cooling medium: 34% ethylene glycol
Supply power: 400V/3P/50Hz
Fan brand: Ziehl-Abegg
Country: Russia
Application:data center cooling
Cooling capacity: 763kW
Cooling medium: water
Supply power: 380V/3P/50Hz
Fan brand: Ziehl-Abegg
Dielectric Fluids V Type Datacentre Immersion Cooling System Dielectric Fluids V Type Datacentre Immersion Cooling System
For power plant Country: Hongkong
Application: power plant
Cooling capacity: 363kW
Cooling medium: water
Supply power: 415V/3P/50Hz
Fan brand: Chinese brand
Country: Russia
Application: power plant.
Cooling capacity: 180kW
Cooling medium: water
Supply power: 380V/3P/50Hz
Fan brand: Chinese brand
Dielectric Fluids V Type Datacentre Immersion Cooling System Dielectric Fluids V Type Datacentre Immersion Cooling System
Send your message to this supplier
Send Now

Dielectric Fluids V Type Datacentre Immersion Cooling System

Ask Latest Price
Brand Name :
Shenglin
Model Number :
H*FD Series Double rows fans
Certification :
CE and RoHs
Place of Origin :
China
MOQ :
1
Price :
6000~49005 USD per unit
Contact Supplier
Dielectric Fluids V Type Datacentre Immersion Cooling System
Dielectric Fluids V Type Datacentre Immersion Cooling System
Dielectric Fluids V Type Datacentre Immersion Cooling System
Dielectric Fluids V Type Datacentre Immersion Cooling System
Dielectric Fluids V Type Datacentre Immersion Cooling System
Dielectric Fluids V Type Datacentre Immersion Cooling System
Dielectric Fluids V Type Datacentre Immersion Cooling System
Dielectric Fluids V Type Datacentre Immersion Cooling System
Dielectric Fluids V Type Datacentre Immersion Cooling System
Dielectric Fluids V Type Datacentre Immersion Cooling System

Shanghai Shenglin M&E Technology Co., Ltd.

Active Member
5 Years
shanghai, shanghai
Since 2009
Business Type :
Manufacturer
Employee Number :
>100
Certification Level :
Active Member
Contact Supplier
Submit Requirement