Adiabatic Cooling System Double Rows Fan Hybrid Dry Coolers
In adiabatic cooling pad systems, cool pads are placed in special sheet metal assemblies which are mounted in front of fin block. With the aid of the pump, water wets the pads from the upper part of the pad system. The outside air, which is dry and hot, is pre-cooled by passing it through wet cooling pads. The temperature of the air that contact with the wet cooling pads is approximated to the wet thermometer temperature. The water does not contact directly with the fins. Thus fins lifetime is longer than the direct spraying systems. Also pads prevent contamination of fins. Since the microorganisms, minerals and similar parts do not mix into the air during the evaporation phase of water, the working principle is completely healthy. The system ensures that product efficiency can be increased with minimum water consumption.
Our Dry Cooler Structure:
Easy To Trasport And Install:
Features of dry cooler
High efficiency heat exchanger: capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany |
Fan: only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw.Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Air separator for each fan. |
We facilitate you to have a long lasting and low maintainance operation. Durable material and rigid enclosure with hard gloss powder coated finish. Protective enclosure for both manifolds and U-bends. Unit design for outdoor installation. 100% leakage tested at 31bar. |
Options
Coil design refrigerant: water, oil, glycol. | Multiple circuits. |
Sub-cooling circuits. | Stainless steel or aluminum casing. |
Coated aluminum or copper fins. | Explosion proof motor. |
Customized fin spacing. |
Advantage
1. Modular designs of dry cooler helps in space optimization
2. High efficient fin and tube heat exchanger
3. Zero water wastage : as it is closed loop operation and now water evaporation
4. Negligible maintenance cost : as water treatment, makeup water and replacement of fills are not required.
5. No periodic cleaning requirement
6. Separates process side from any contamination due to closed loop system
7. Casing made of galvanzied steel, enhanced corrosion resistance.
Technical parameter
Dry cooler D2 series parameter(fin space 2.1mm)
Type | D2-148- 4x630 | D2-166- 4x630 | D2-175- 4x630 | D2-228- 6x630 | D2-250- 6x630 | D2-276- 6x630 | D2-310- 8x630 | D2-343- 8x630 | D2-364- 8x630 | D2-392- 10x630 | |||
Capacity | Water | KW | 147.99 | 165.85 | 175.21 | 227.85 | 250.42 | 276.53 | 309.85 | 342.73 | 364.07 | 391.99 | |
20% Et. Glycol | KW | 142.42 | 161.57 | 170.91 | 219.09 | 244.69 | 270.22 | 301.18 | 333.55 | 354.64 | 383.3 | ||
Air flow | M3/h | 76459 | 74341 | 72134 | 114686 | 111511 | 108188 | 152911 | 148675 | 144255 | 191136 | ||
Fan | No. X φ | 2x2x630 | 2x2x630 | 2x2x630 | 2x3x630 | 2x3x630 | 2x3x630 | 2x4x630 | 2x4x630 | 2x4x630 | 2x5x630 | ||
Fan motor | A | 20.4 | 20.4 | 20.4 | 30.6 | 30.6 | 30.6 | 40.8 | 40.8 | 40.8 | 51 | ||
400/3N/50HZ | |||||||||||||
Sound pressure level | dB(A)10m | 64 | 64 | 64 | 66 | 66 | 66 | 67 | 67 | 67 | 68 | ||
Dimension | L | mm | 2186 | 2186 | 2186 | 3250 | 3250 | 3250 | 4250 | 4250 | 4250 | 5250 | |
H | mm | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | ||
D | mm | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | ||
D1 | mm | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
L1 | mm | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | ||
L2 | mm | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
L3 | mm | 1963 | 1963 | 1963 | 2963 | 2963 | 2963 | 3963 | 3963 | 3963 | 4963 | ||
Connections inlet φ | mm | 2XDN50 | 2XDN65 | 2XDN65 | 2XDN65 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN100 | 2XDN100 | ||
Connections onlet φ | mm | 2XDN50 | 2XDN65 | 2XDN65 | 2XDN65 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN100 | 2XDN100 | ||
Product weight(empty) | kg | 769 | 811 | 853 | 1134 | 1197 | 1261 | 1498 | 1589 | 1673 | 1864 |
Shenglin dry cooler selection software example:
Some reference:
![]() | ![]() |
Country: USA Application: Bitcoin immersion cooling system Cooling capacity: 1270kW Cooling medium: BC-888 Supply power: 415V/3P/60Hz Fan brand: Ziehl-Abegg
| Country: USA Application: Bitcoin immersion cooling system Cooling capacity: 171kW Cooling medium: bitcoin fluid Supply power: 415V/3P/60Hz Fan brand: Chinese brand
|