649kw Hydrophilic Aluminum Fin Closed Loop Cooling Systems Fluid Coolers
Dry cooler vs wet cooling tower:
Dry coolers are heat-transfer devices that use air to remove excess heat into the atmosphere. Usually, a dry cooler presents a heat exchanger (usually fin heat exchanger) and fans. The fans are responsible for directing the air flow through the heat exchanger. Here is where the fluid (it can be water or another solution) is cooled and then circulated back into the system.
Sure, for a dry cooler to be efficient, the air temperature needs to be cooler than the water (or any other glycol solution) in the system. This explains why, for example, dry coolers work better in cold climate regions (while wet cooling towers are more efficient in hot and dry climates). Dry coolers tend to not be affected by air humidity, on the contrary of wet cooling towers.
Dry coolers have a limited cooling capacity, compared to wet cooling towers: the first one only brings the water temperature down to the ambient temperature (additional cooling can be achieved in other ways), while the latter can bring the water temperature up to 5 degrees down the ambient temperature.
Dry cooler features:
Air discharge direction | ![]() |
Performance ranges | Cooling capacity: from 5 to 649 kw Air volume: from 2828 to 263503 m3/h Sound pressure level: from 31 to 69 dB A(10m) Dry coolers:customized on demand |
High efficiency heat exchanger | Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany |
Fan | Only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw. Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Voltage:400V/3N/50Hz Air separator for each fan. |
Testing | Heat exchangers are supplied clean and tested at a pressure of 30 bars |
Options | Coil design refrigerant: water, oil, glycol. Multiple circuits. Sub-cooling circuits. Stainless steel or aluminum casing. Coated aluminum or copper fins. Explosion ploof motor. Customized fin spacing.
|
Dry Cooler technical parameter
Dry cooler D1 series parameter(fin space 2.1mm)
Type | D1-166- 4x630 | D1-211- 6x630 | D1-247- 6x630 | D1-286- 8x630 | D1-334- 8x630 | D1-360- 10x630 | D1-415- 10x630 | D1-502- 12x630 | D1-565- 14x630 | D1-649- 16x630 | ||||||
Capacity | Water | 35℃ outdoor temp. | Inlet | 45℃, | △ | KW | 165.92 | 211.36 | 247.3 | 286.15 | 334.49 | 359.72 | 415.31 | 502.25 | 565.18 | 649.48 |
outlet | 40℃ | Y | 134.59 | 176.00 | 200.45 | 238.3 | 270.889 | 298.57 | 335.225 | 405.20 | 459.3 | 527.59 | ||||
20% Glycol | Inlet | 45℃ | △ | 161.32 | 205.08 | 240.46 | 280.05 | 327.72 | 351.3 | 406.48 | 493.40 | 554.21 | 638.44 | |||
outlet | 40℃ | Y | 130.96 | 170.87 | 195.07 | 233.18 | 265.64 | 291.81 | 328.48 | 398.45 | 450.87 | 519.13 | ||||
Medium | Water flow | M3/h | 29.00 | 37 | 43 | 50 | 58 | 63 | 72 | 88 | 98 | 113 | ||||
Pressure drop | kPa | 50 | 70 | 47 | 97 | 95 | 92 | 70 | 97 | 96 | 95 | |||||
Air flow | △ | M3/h | 67455 | 109723 | 101185 | 146293 | 134908 | 179502 | 164442 | 197326 | 230584 | 263503 | ||||
Y | 51265 | 83661 | 76900 | 111544 | 102528 | 136437 | 124680 | 149612 | 174710 | 199665 | ||||||
Fan motor | Phase | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |||||
△ | W | 1100 | 16500 | 16500 | 22000 | 22000 | 27500 | 27500 | 33000 | 38500 | 44000 | |||||
Y | 700 | 10500 | 10500 | 14000 | 14000 | 17500 | 17500 | 21000 | 24500 | 28000 | ||||||
△ | A | 20.4 | 30.6 | 30.6 | 40.8 | 40.8 | 51.00 | 51.00 | 61.20 | 71.40 | 81.60 | |||||
Y | 12.00 | 18.00 | 18.00 | 24.00 | 24.00 | 30.00 | 30.00 | 36.00 | 42.00 | 48.00 | ||||||
Fan | No X φ | 2X2 X630 | 2x3 x630 | 2x3 x630 | 2x4 x630 | 2x4 x630 | 2x5 x630 | 2x5 x630 | 2x6 x630 | 2x7 x630 | 2x8 x630 | |||||
Sound pressure level | △ | dB(A) | 64 | 66 | 66 | 67 | 67 | 68 | 68 | 68 | 69 | 69 | ||||
Y | 10m | 57 | 59 | 59 | 60 | 60 | 61 | 61 | 61 | 62 | 62 | |||||
Dimension | L | mm | 2930 | 4230 | 4230 | 5530 | 5530 | 6830 | 6830 | 8130 | 9430 | 10730 | ||||
W | mm | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | |||||
H | mm | 1070 | 1070 | 1070 | 1070 | 1070 | 1120 | 1120 | 1120 | 1120 | 1120 | |||||
A | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
B | mm | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | |||||
C | mm | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | |||||
D | mm | 640 | 640 | 640 | 640 | 640 | 640 | 640 | 640 | 640 | 640 | |||||
Inlet φ | mm | 3” | 3” | 3” | DN100 | DN100 | DN100 | DN125 | DN125 | 2X DN125 | 2X DN125 | |||||
Inlet φ | mm | 3” | 3” | 3” | DN100 | DN100 | DN100 | DN125 | DN125 | 2X DN125 | 2X DN125 | |||||
Product weight(empty) | kg | 658 | 689 | 760 | 1105 | 1270 | 1320 | 1420 | 1584 | 1848 | 2112 |
Application:
Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, sloar system, smelting, etc.. It is suitable for all equipment which needs heat dissipation and is installed in the open air.
Shenglin dry cooler selection software example:
How does immersion cooling work and what is the impact on the future of data centers?
Immersion cooling is a process in which servers and other IT hardware are immersed in non-conductive fluids such as 3M™ Novec™ Engineered Fluids. Heat generated by the electronic components is transferred to the fluid, reducing the need for active cooling components, such as interface materials, heat sinks and fans that are common in air cooling.
Data centers will need to improve energy efficiency and reduce size to keep up with the data demand. Liquid immersion cooling in data centers offers a unique opportunity to reduce cooling costs by 95% and reduce data center size by 10x.
Shenglin and Shenglin partner can offer one-stop solution:
For bitcoin mining farm, if use immersion cooling system, Shenglin dry cooler is the most cost-effective way to remove heat and a necessary component of the immersion cooling system, We designed a full range of immersion optimized dry coolers. From 5kW single fan unit to the V-shaped 48-921kW dry coolers. Made in China, sized to your needs.
Like this way: