Specifications
Brand Name :
Shenglin
Model Number :
D1 Series
Certification :
CE certification
Place of Origin :
China
MOQ :
1
Price :
505~31005 USD/Unit
Payment Terms :
T/T, Western Union
Supply Ability :
50~100 units per month
Delivery Time :
35~40days
Packaging Details :
For sample and less than container order: plywood case. For Container order: pallet and wrapping film
Tube material :
Inner grooved copper tube
Fin material :
Hydrophilic aluminum fin or epoxy resin aluminum fin
Frame material :
Galvanized steel plate or stainless steel or aluminum
Fan brand :
High efficient axial, external rotor motor, Ziehl Abegg or equivalent fans
Application in HVAC 1 :
For data center air conditioning
Application in HVAC 2 :
Match with water cooled chiller
Application in HVAC 3 :
Immersion cooling system
Coil structure :
Floated type
Design capacity :
We can design and taior made for you with your specification.
Medium in tube :
Glycol/water
Description

V-Type Copper Tube Dry Type Air Cooler For Immersion Cooling System

What is closed-loop dry cooling system?

The strength of a closed-loop dry cooling system is that the unit is very simple and relatively easy to install. The energy requirements are relatively low and it is easily controlled. Maintenance is normally low requiring only periodic inspection, lubrication, and testing of the fluid.

The weakness of a closed-loop dry cooling system is that it is dependent on the atmospheric dry bulb. For example, if your location’s design dry bulb is 100 F in the summer and your equipment requires 90 F coolant; at best the system can only supply around 105 to 110 F coolant to the load. In this case you would need supplemental cooling to get the coolant temperatures down to 90 F.

The closed-loop dry cooling system also requires free clear air to work efficiently. This means that the fluid cooler must be placed in a location that is not affected by the prevailing winds, not too close to a building that will allow the warm exhaust air from the fluid cooler to be recirculated back to the fluid cooler, and finally not in a location that has heavy concentrations of dust, dirt, leaves, seeds, etc.

Many times the best location for the fluid cooler is on the roof. Since the fluid cooler is located outside the coolant must also have a concentration of some type of glycol to prevent freezing if your location has a design dry bulb in the winter that dips below freezing. If the location is very cold, the concentration of glycol may need to be significant to prevent freezing. Glycol concentrations as they increase begin to reduce the rate of heat transfer. For example, if you need 50% ethylene glycol concentration with water the heat exchanger equipment and the flow/pressure of the coolant will need to increase to adjust for the glycol concentration. Larger fluid coolers and pumps will increase the cost of the system over those with lesser concentrations of Glycol/water. This cannot be prevented in colder climates.

Dry fluid cooler features:

Air discharge direction V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System
Performance ranges

Cooling capacity: from 5 to 649 kw

Air volume: from 2828 to 263503 m3/h

Sound pressure level: from 31 to 69 dB A(10m)

Dry coolers:customized on demand

High efficiency heat exchanger

Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan.

Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition).

Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany

Fan

Only choose low specific energy consumption fans.

Fan nozzle designs for maximum air flow and air throw.

Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting.

Motor: protection class IP 54 and insulation class F.

Voltage:400V/3N/50Hz

Air separator for each fan.

Testing Heat exchangers are supplied clean and tested at a pressure of 30 bars
Options

Coil design refrigerant: water, oil, glycol.

Multiple circuits.

Sub-cooling circuits.

Stainless steel or aluminum casing.

Coated aluminum or copper fins.

Explosion ploof motor.

Customized fin spacing.

Dry fluid cooler technical parameter

Dry cooler D1 series parameter(fin space 2.1mm)

Type

D1-166-

4x630

D1-211-

6x630

D1-247-

6x630

D1-286-

8x630

D1-334-

8x630

D1-360-

10x630

D1-415-

10x630

D1-502-

12x630

D1-565-

14x630

D1-649-

16x630

Capacity Water 35℃ outdoor temp. Inlet 45℃, KW 165.92 211.36 247.3 286.15 334.49 359.72 415.31 502.25 565.18 649.48
outlet 40℃ Y 134.59 176.00 200.45 238.3 270.889 298.57 335.225 405.20 459.3 527.59
20% Glycol Inlet 45℃ 161.32 205.08 240.46 280.05 327.72 351.3 406.48 493.40 554.21 638.44
outlet 40℃ Y 130.96 170.87 195.07 233.18 265.64 291.81 328.48 398.45 450.87 519.13
Medium Water flow M3/h 29.00 37 43 50 58 63 72 88 98 113
Pressure drop kPa 50 70 47 97 95 92 70 97 96 95
Air flow M3/h 67455 109723 101185 146293 134908 179502 164442 197326 230584 263503
Y 51265 83661 76900 111544 102528 136437 124680 149612 174710 199665
Fan motor Phase 3 3 3 3 3 3 3 3 3 3
W 1100 16500 16500 22000 22000 27500 27500 33000 38500 44000
Y 700 10500 10500 14000 14000 17500 17500 21000 24500 28000
A 20.4 30.6 30.6 40.8 40.8 51.00 51.00 61.20 71.40 81.60
Y 12.00 18.00 18.00 24.00 24.00 30.00 30.00 36.00 42.00 48.00
Fan No X φ

2X2

X630

2x3

x630

2x3

x630

2x4

x630

2x4

x630

2x5

x630

2x5

x630

2x6

x630

2x7

x630

2x8

x630

Sound pressure level dB(A) 64 66 66 67 67 68 68 68 69 69
Y 10m 57 59 59 60 60 61 61 61 62 62
Dimension L mm 2930 4230 4230 5530 5530 6830 6830 8130 9430 10730
W mm 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100
H mm 1070 1070 1070 1070 1070 1120 1120 1120 1120 1120
A mm -- -- -- -- -- -- -- -- -- --
B mm 1340 1340 1340 1340 1340 1340 1340 1340 1340 1340
C mm 1300 1300 1300 1300 1300 1300 1300 1300 1300 1300
D mm 640 640 640 640 640 640 640 640 640 640
Inlet φ mm 3” 3” 3” DN100 DN100 DN100 DN125 DN125

2X

DN125

2X

DN125

Inlet φ mm 3” 3” 3” DN100 DN100 DN100 DN125 DN125

2X

DN125

2X

DN125

Product weight(empty) kg 658 689 760 1105 1270 1320 1420 1584 1848 2112

Application:

Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, sloar system, smelting, etc.. It is suitable for all equipment which needs heat dissipation and is installed in the open air.

How to design a dry cooler?

Tell Shenglin the datas as following:
A. Required electrolyte inlet temperature?
B. Required electrolyte​ outlet temperature?
C. Electrolyte​ flow?
D. Ambient temperature?
E. Supply power(voltage-Hz-phase)
G. Any other requirements ?

Reference:

For solar industry Country: China
Application :cooling of solar heating system when it is overheated
Cooling capacity: 463, 933 and 1475kW
Cooling medium: 50% propylene glycol water
Supply power: 380V/3P/50Hz
Fan brand: Ziehl-Abegg
Altitude:4200m
Country: UAE
Application: solar thermal system
Cooling capacity: 21kw
Cooling medium: water
Supply power: 230V/1P/50Hz
Fan brand: Chinese brand
Country: Korea
Application: solar system overheated
Cooling capacity: 32kW
Cooling medium: 30% ethylene glycol water
Supply power: 230V/1P/60Hz
Fan brand: Chinese brand
V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System
For plastic industry Country: Algeria
Application: cooling water from injection molding machine
Cooling capacity: 694kW
Cooling medium: water
Supply power: 400V/3P/50Hz
Fan brand: Ziehl-Abegg
Country: Armenia
Application: for plastic caps of beverages factory
Cooling capacity:70kW
Cooling medium: 34% ethylene glycol
Supply power: 380V/3P/50Hz
Fan brand: Chinese brand
Country: Russia
Application: bathtub factory
Inlet/outlet air temperature:40℃/66℃
Inlet/outlet water temperature:85℃/50℃
Air volume:7986m3/h
Cooling medium:water
Supply power: 380V/3P/50Hz
Fan brand: Chinese brand
V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System
Instead of cooling tower Country: Argentina
Application: for equipment cooling, to match chiller.
Cooling capacity: 245kW
Cooling medium: water
Supply power:380V/3P/50Hz
Fan brand: Chinese brand


Country: Peru
Application: instead of cooling tower, to match chiller.
Cooling capacity: 360kW
Cooling medium: water
Supply power:440V/3P/60Hz
Fan brand: Chinese brand
With wet curtain, with water pump and water tank
Country: Mauritius
Application: supermarket and will match chiller use.
Heat transfer capacity: 502kW
Cooling medium: water
Inlet air temp.: 32℃
Inlet medium temp.: 42℃
Outlet medium temp.: 37℃
Medium volume: 88m3/h
Material: copper tube aluminum fin and galvanized steel frame, RAL9010 powder coating.
Supply power: 380V/3P/50Hz
Fan brand: Chinese brand, air volume: 20228m3/h
V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System
For data center cooling Country: Mongolia
Application: match with precision air conditioner
Cooling capacity: 17.6kW
Cooling medium: 34% ethylene glycol
Supply power: 400V/3P/50Hz
Fan brand: Ziehl-Abegg
Country: Russia
Application:data center cooling
Cooling capacity: 763kW
Cooling medium: water
Supply power: 380V/3P/50Hz
Fan brand: Ziehl-Abegg
V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System
Factory cooling Country: Russia
Application: ore yard cooling
Cooling capacity: 493kW
Cooling medium: 20% ethylene glycol
Supply power: 400V/3P/50Hz
Fan brand: Ziehl-Abegg
Country: China
Application: plant cooling
Cooling capacity: 52kW
Cooling medium: 30% ethylene glycol
Supply power: 380V/3P/50Hz
Fan brand: Chinese brand
V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System
For power plant Country: Hongkong
Application: power plant
Cooling capacity: 363kW
Cooling medium: water
Supply power: 415V/3P/50Hz
Fan brand: Chinese brand
Country: Russia
Application: power plant.
Cooling capacity: 180kW
Cooling medium: water
Supply power: 380V/3P/50Hz
Fan brand: Chinese brand
V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System
Other application Country: Singapore
Application: match with fruit and vegerable freezer
Cooling capacity: 14.6kw, 17kw and 29.37kw
Cooling medium: 20% ethylene glycol
Supply power: 230V/1P/50Hz
Fan brand: Ziehl-Abegg
Country: Singapore
Application: wastewater treatment factory, cooling water
Cooling capacity: 429kW
Cooling medium: water
Supply power: 400V/3P/50Hz
Fan brand: Ziehl-Abegg
Country: Russia
Application: industrial cooling
Cooling capacity: 153kW
Cooling medium: 20% glycol
Supply power: 380V/3P/50Hz
Fan brand: Ziehl-Abegg
V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System
Send your message to this supplier
Send Now

V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System

Ask Latest Price
Watch Video
Brand Name :
Shenglin
Model Number :
D1 Series
Certification :
CE certification
Place of Origin :
China
MOQ :
1
Price :
505~31005 USD/Unit
Contact Supplier
video
V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System
V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System
V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System
V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System
V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System

Shanghai Shenglin M&E Technology Co., Ltd.

Active Member
5 Years
shanghai, shanghai
Since 2009
Business Type :
Manufacturer
Employee Number :
>100
Certification Level :