Single-stage horizontal double-shaft BW cycloid reducer: BW0, BW1, BW2, BW3, BW4, BW5, BW6, BW7, BW8, BW9, BW10, BW11, BW12
Single-stage horizontal disc type (connected to motor flange) BWK cycloid reducer: BWK1, BWK2, BWK3, BWK4, BWK5, BWK6, BWK7, BWK8, BWK9, BWK10, BWK11, BWK12
Single-stage horizontal direct-connected BWD cycloid reducer: BWD1, BWD2, BWD3, BWD4, BWD5, BWD6, BWD7, BWD8, BWD9, BWD10, BWD11, BWD12
Single-stage vertical double-shaft BL cycloid reducer: BL0, BL1, BL2, BL3, BL4, BL5, BL6, BL7, BL8, BL9, BL10, BL11, BL12 Single-stage vertical type BLK cycloid reducer: BLK1, BLK2, BLK3, BLK4, BLK5, BLK6, BLK7, BLK8, BLK9, BLK10, BLK11, BLK12
Single-stage vertical motor direct-connected BLD cycloid reducer: BLD1, BLD2, BLD3, BLD4, BLD5, BLD6, BLD7, BLD8, BLD9, BLD10, BLD11, BLD12
Two-stage horizontal double-shaft BWE cycloid reducer: BWE20, BWE32, BWE42, BWE53, BWE63, BXWE74, BWE84, BWE85, BWE95, BWE106, BWE128
Two-stage horizontal disk type (connected to motor flange) BWEK cycloid reducer: BWEK20, BWEK32, BWEK42, BWEK53, BWEK63, BWEK74, BWEK84, BWEK85, BWEK95, BWEK106, BWEK128
Two-stage horizontal motor (connected to motor flange) direct-connected BWED cycloid reducer: BWED20, BWED32, BWED42, BWED53, BWED63, BWED74, BWED84, BWED85, BWED95, BWED106, BWED128
Double-stage vertical double-shaft BLE planetary cycloid reducer: BLE20, BLE32, BLE42, BLE53, BLE63, BLE74, BLE84, BLE85, BLE95, BLE106, BLE128
Two-stage vertical type BLEK cycloid reducer: BLEK20, BLEK32, BLEK42, BLEK53, BLEK63, BLEK74, BLEK84, BLEK85, BLEK95, BLEK106, BLEK128
Two-stage vertical motor direct-connected BLED cycloid reducer: BLED20, BLED32, BLED42, BLED53, BLED63, BLED74, BLEDK84, BLED85, BLED95, BLED106, BLED128
1. The horizontal cycloid reducer is lubricated by oil pool under normal conditions, and the oil level can be kept in the middle of the oil window. When the working conditions are harsh and the ambient temperature is high, circulating lubrication can be used. 2. When refueling, screw the ventilation cap on the upper part of the base to refuel. When draining oil, unscrew the drain plug at the bottom of the base to drain the dirty oil. The reducer is shipped without lubricating oil inside. 3. The first refueling operation for 100 hours should be replaced with new oil, (and the internal dirty oil should be flushed) and then continue to work, and replaced every six months (8-hour work system). If the working conditions are bad, the oil change time can be shortened appropriately. Practice has proved that the frequent cleaning and oil change of the reducer (such as 3-6 months)