6TPH Drinking Water Making Machine RO Water Treatment System
Drinking water RO system membrane:
It is a semi-permeable membrane artificially synthesized by a special process in order to realize the reverse osmosis phenomenon of the aqueous solution. The pore size of the reverse osmosis membrane is 0.0001µm, and only the solvent in the aqueous solution, water, can pass through, while its solute cannot pass through the reverse osmosis membrane. The diameter of the virus is 0.02-0.4µm, and the diameter of the bacteria is 0.4-1.0µm. Therefore, the water passing through the reverse osmosis membrane is truly pure water.
Technical specifications of drinking water RO system:
Model | JFRO-6000L |
Host Size | 3000x800x1600mm (can be customized) |
Power | 5.5KW |
Power Supply | 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized |
Operating Pressure | 0.8-1.2MPa |
Recovery Rate | 60% |
Designed Water Inlet | 10000L/h |
Outlet Flow | 6000L/h |
Desalination Rate | ≥99.5% |
RO Frame | SUS304 |
Membrane Size | 8040 |
Membrane Elements | DOW /Hydranautics/Troy/ Vontron (Optional) |
Number of Membranes | 6 |
Raw Water Pump | CNP/NYP/GRUNDFOS (Optional) |
High Pressure Pump | CNP/NYP/GRUNDFOS (Optional) |
Tank Material | SS/FRP(Optional) |
Control Valve | Manual/Automatic |
Control Valve Brand | FLECK/RUNXIN |
Membrane Housing | FRP |
Number of Membrane housing | 3 |
Pipe Material | U-PVC/ Stainless steel (Optional) |
Working Process of Drinking Water RO System
How does drinking water RO system membrane works?
A membrane that is selective for permeable substances is called a semi-permeable membrane, and a membrane that can only permeate a solvent but cannot permeate a solute is generally called an ideal semi-permeable membrane. When the same volume of dilute solution (such as fresh water) and concentrated solution (such as salt water) are placed on both sides of the semipermeable membrane, the solvent in the dilute solution will naturally pass through the semipermeable membrane and flow to the concentrated solution side spontaneously, This phenomenon is called penetration. When the osmosis reaches equilibrium, the liquid level on the side of the concentrated solution will be higher than the liquid level of the dilute solution by a certain height, that is, a pressure difference is formed, and this pressure difference is the osmotic pressure (see the figure for the working principle of the reverse osmosis membrane).
FAQ:
1. What is the shell film material and specification of ro water treatment system?
Material of membrane case: stainless steel and fiberglass (FRP)
Specification of membrane shell: four inch membrane shell 4040 (one core to four core)
8 inch membrane case 8040 (one to seven cores)
Water inlet: end water inlet, side water inlet
2. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)
Model 4040 is designed by 0.25m3/h
Model 8040 is designed by 1-1.2m3/h
3. What is the material of mechanical filter?
Carbon steel, stainless steel, fiberglass