6TPH Automatic Control Reverse Osmosis Drinking Water Making Plant
Advanced drinking water ro system - reverse osmosis membrane (RO):
The pore size of the reverse osmosis membrane is the smallest, below 2-3 nm. Except for water molecules, all other impurity particles (including ions) cannot pass through the reverse osmosis membrane, so the water separated by the reverse osmosis membrane is pure water. Reverse osmosis technology has been widely used in seawater desalination, brackish water desalination, and preparation of high-purity water for industrial feed water (electronic industrial water, boiler feed water, etc.). The core technology of drinking pure water and high-quality direct drinking water that has developed rapidly in recent years is reverse osmosis.
Technical specifications of Drinking Water RO System
Model | JFRO-6000L |
Host Size | 3000x800x1600mm (can be customized) |
Power | 5.5KW |
Power Supply | 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized |
Operating Pressure | 0.8-1.2MPa |
Recovery Rate | 60% |
Designed Water Inlet | 10000L/h |
Outlet Flow | 6000L/h |
Desalination Rate | ≥99.5% |
RO Frame | SUS304 |
Membrane Size | 8040 |
Membrane Elements | DOW /Hydranautics/Troy/ Vontron (Optional) |
Number of Membranes | 6 |
Raw Water Pump | CNP/NYP/GRUNDFOS (Optional) |
High Pressure Pump | CNP/NYP/GRUNDFOS (Optional) |
Tank Material | SS/FRP(Optional) |
Control Valve | Manual/Automatic |
Control Valve Brand | FLECK/RUNXIN |
Membrane Housing | FRP |
Number of Membrane housing | 3 |
Pipe Material | U-PVC/ Stainless steel (Optional) |
Drinking Water RO System workflow:
raw water - raw water tank - raw water booster pump - quartz sand filter - activated carbon filter - scale inhibitor dosing equipment - precision filter - first-stage high pressure pump - first-stage reverse osmosis Host - intermediate water tank - secondary high pressure pump - secondary reverse osmosis host - disinfection system - production water.
Drinking water reverse osmosis system generally includes pretreatment system, reverse osmosis device, post-treatment system, cleaning system and electrical control system.
1, the pretreatment system generally includes the original water pump, dosing device, quartz sand filter, activated carbon filter, precision filter, etc. Its main function is to reduce the pollution index of raw water and other impurities such as residual chlorine to meet the requirements of reverse osmosis inlet water.
2. Reverse osmosis device mainly consists of multistage high pressure pump, reverse osmosis membrane element, membrane shell (pressure vessel), bracket and so on. Its main function is to remove impurities in water, so that the water meets the requirements of use.
3. Post-treatment system is an additional configuration in the case that reverse osmosis cannot meet the requirements of outlet water. Mainly including negative bed, positive bed, mixed bed, sterilization, ultrafiltration and other one or more of the equipment.
4, cleaning system is mainly composed of cleaning water tank, cleaning water pump, precision filter. When the reverse osmosis system is polluted and the effluent index cannot meet the requirements, it is necessary to clean the reverse osmosis system to restore its efficacy.
5. Electrical control system is used to control the normal operation of the whole reverse osmosis system. Including instrument panel, control panel, all kinds of electrical protection, electrical control cabinet, etc.
FAQ:
1. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)
Model 4040 is designed by 0.25m3/h
Model 8040 is designed by 1-1.2m3/h
2. What is the material of mechanical filter?
Carbon steel, stainless steel, fiberglass
3. what are the multi-way control valves?
Manual control valve, automatic control valve
Multi - way control valve is divided into: filter valve and softening valve
Automatic control valve is divided into: time type and flow type.