Product Introduction of RO Water Treatment System
The system desalination rate of reverse osmosis equipment is generally 98-99%. Such a desalination rate can meet the requirements in most cases. In the electronics industry, ultra-high pressure boiler feed water, and individual pharmaceutical industries, the requirements for pure water Probably higher. At this time, single-stage reverse osmosis equipment cannot meet the requirements.Osmosis is common in nature. For example, if you put a cucumber in salt water, the cucumber will shrink due to water loss. The process by which the water molecules in the cucumber enter the brine solution is the process of osmosis. If a pool is divided into two parts by a membrane that only water molecules can pass through, inject pure water and salt water to the same height on both sides of the membrane. After a period of time, it can be found that the liquid level of pure water has decreased, while the liquid level of salt water has increased. We call the phenomenon of water molecules migrating through this membrane into the brine as osmosis. The rise of the brine level is not endless, and it will reach a balance point at a certain height. At this time, the pressure represented by the liquid level difference at both ends of the diaphragm is called the osmotic pressure. The size of osmotic pressure is directly related to the concentration of saline.
The Basic Working Principle of RO Water Treatment System
After a special high-pressure pump, when the raw water is added to a pressure of 6-20 kg, the raw water permeates through the reverse osmosis membrane with a pore size of only 0.0001 microns under the action of pressure. Chemical ions, bacteria, fungi, and virions cannot pass through, and are discharged with wastewater. Only water molecules and solvents with a volume of less than 0.0001 microns are allowed to pass through.
Technical Specifications of RO Water Treatment System
500LPH Reverse Osmosis System | |
Model | JFRO-500L |
Host Size | 800x600x1600mm (can be customized) |
Power | 1.5KW |
Power Supply | 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized |
Operating Pressure | 0.8-1.2MPa |
Recovery Rate | 50% |
Designed Water Inlet | 1000L/h |
Outlet Flow | 500L/h |
Desalination Rate | ≥99.5% |
RO Frame | SUS304 |
Membrane Size | 4040 |
Membrane Elements | DOW /Hydranautics/Troy/ Vontron (Optional) |
Number of Membranes | 2 |
Raw Water Pump | CNP/NYP/GRUNDFOS (Optional) |
Raw Water Pump | CNP/NYP/GRUNDFOS (Optional) |
Tank Material | SS/FRP (Optional) |
Control Valve | Manual/Automatic |
Control Valve Brand | FLECK/RUNXIN |
Membrane Housing | SS/FRP (Optional) |
Pipe Material | U-PVC, Stainless steel (Optional) |
Application fields of RO water treatment system
Water treatment system treat raw water in several procedures in order to meet the bottled drinking water standard.
This system uses water pressure pump to increase the water supply pressure; sand filter is used to remove Plankton, Moss, Suspension, Colloid and so on. Active carbon filter is used to remove strange smell, chlorine, chloride, organic matter and heavy mental, lower color and optimize water quality. Sodium softer is used to remove the calcium and magnesium ions in water. Micro filter is used to remove the tiny impurity. Hollow fiber Ultra filter can remove impurity, colloid, phenolic compounds, chloride, germ and all the harmful substance, meanwhile keep all beneficial minerals in water. Reverse osmosis can move all the things in the water and to make raw water to be pure water.
Advantages of reverse osmosis:
Continuous operation, stable product water quality
No need for acid-base regeneration
No downtime for regeneration
Saves water for backflushing and cleaning
Produce ultrapure water at high yields (yields can be as high as 95%)
No regenerated sewage, no need for sewage treatment facilities
No need for acid-base storage and acid-base dilution transport facilities
Reduce the building area of the workshop
It is safe and reliable to use, preventing workers from contacting acid and alkali
Reduce operation and maintenance costs
Simple installation and low installation cost
Process flow of RO Water Treatment System
Raw water → Raw water tank → Raw water pump → Multi-media filter (quartz sand filter) → Activated carbon filter → Soft water processor → Precision filter → High pressure pump → Primary reverse osmosis (RO) device → Purified water tank → High pressure pump → Two Stage reverse osmosis → ultraviolet sterilization device → water point.
Photos of reverse osmosis water treatment system
FAQ:
1. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)
Model 4040 is designed by 0.25m3/h
Model 8040 is designed by 1-1.2m3/h
2. What is the material of mechanical filter?
Carbon steel, stainless steel, fiberglass
3.What are the multi-way control valves?
Manual control valve, automatic control valve
Multi - way control valve is divided into: filter valve and softening valve
Automatic control valve is divided into: time type and flow type.
Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.