Specifications
Brand Name :
ZL
Model Number :
ZL-5066
Certification :
CE,ISO
Place of Origin :
China
MOQ :
1 set
Price :
Negotiable
Payment Terms :
L/C, T/T, Western Union
Supply Ability :
60 Sets
Delivery Time :
5-8 work days
Packaging Details :
PLC Mask Partical Filtration Efficiency Tester ( PFE ) with PSL Test Aerosol is packaged within wooden case.
Product name :
PLC Mask Partical Filtration Efficiency Tester ( PFE ) with PSL Test Aerosol
Test area :
100cm²
Counter sampling flow rate :
2.83L / min ± 5%
Counter laser light source :
Laser diode
Screen display :
Color 7-inch touch screen
Data export interface :
USB
Power supply :
AC 220V / 50Hz
Meet Standard: :
GB 19082, GB / T 32610, YY 0969, ISO-29463
Description

PLC Mask Partical Filtration Efficiency Tester ( PFE ) with PSL Test Aerosol

Product Overview:

T433S mask filtration efficiency tester is suitable for testing 45% -99.9% grade filter material efficiency test, and the filter material is tested according to international standards. The design structure of the whole tester is compact and light, and in the process of running the test, it only needs to provide additional suitable power and compressed air (no water, no oil), suitable for use in laboratories, factories and other occasions.

In the filter paper test, the particle counting method is used to measure the counting efficiency. It is recommended to use monodisperse aerosol in the test. The pressure drop measurement should be performed at the specified filtration rate.

Fix the filter paper on the fixture, and the test air volume corresponds to the required filter speed. The aerosol generated by the aerosol generator is adjusted, then electrostatically neutralized (PSL), and then evenly mixed with the filtered test air, and then enters the test area to penetrate the filter material.

In addition, the resistance of the filter material during the test must be measured and the flow rate adjusted manually.

Meet Standard:

GB 19082-2009 Technical requirements for medical disposable protective clothing

GB 19083-2010 Technical requirements for medical protective masks

GB / T 32610-2016 Technical Specifications of Daily Protective Masks

GB 2626-2006 Respiratory protective equipment-Self-suction filter anti-particulate respirator

YY 0969-2013 Disposable medical masks

YY 0469-2011 medical surgical mask

ISO-29463 high-efficiency filters and filter media for removing particulates from the air

Technical parameter

Mask Filtration Efficiency Tester
Model ZL-5066
Test efficiency range

45%-99.95%@≥ 0.3μ m

Test area

100cm²

Test pressure range 0-50pa ± 1%, 50-500pa ± 1.5%
Test flow of the tested filter material

25-100L / min ± 2.5% (adjustable)

Test aerosol type

PSL

Counter sampling flow rate

2.83L / min ± 5%

Particle size display

@ ≥0.3um

Counter laser light source Laser diode
Laser Particle Counter

Products comply with JJF1190-2008

Imported air pump

Works continuously and stably

Data memory capacity

1∽ 1000 sets of measurement data, exportable

Screen display

Color 7-inch touch screen

Printing method built-in thermal printer
Power supply AC 220V / 50Hz
Power

1kw

Data export interface USB

Environment

Operating environment:

0∽ 40 ℃ relative humidity 10∽ 70%

Storage environment:

0 ℃ ∽ 45 ℃ Relative humidity 0∽ 70%

Standard accessories

Thermal paper, hose (outer diameter 6mm and 15mm), instruction manual, test report, certificate of conformity

Dimensions

Length 1000X Width 760X Height 1750 (mm)

Material Shell steel plate paint, test parts SUS304 stainless steel
Weight 150Kg
Warranty 1 year

Accessories

PSL aerosol generator
Electrostatic neutralizer
Diluter

Component

1. Aerosol generator

It is mainly used for experiments requiring high-concentration aerosols. It uses 0.3um PSL standard particles. The size of the main particles emitted is ≥0.3um, accounting for more than 70% of the total. It can produce aerosols continuously and stably. Provide the test particles upstream of the filter material.

2. Particle Counter

It is mainly used to monitor the upstream and downstream particle concentration of the measured filter material to obtain the efficiency of the measured filter material.

3. Stainless steel fixture

It is mainly used for the compression and sealing of the tested filter material.

4. Differential pressure sensor

It is mainly used to test the pressure difference (or resistance) of the tested filter material under a certain test flow rate.

5. Electrical control and software

Equipment circuit control and operation, software calculation and data processing, upstream concentration stability judgment, operation control, parameter setting.

6. Imported air pump

Mainly used for the test flow through the filter material, the flow is stable, green and energy saving, and the vibration noise is small.

PLC Mask Partical Filtration Efficiency Tester ( PFE ) With PSL Test Aerosol

Send your message to this supplier
Send Now

PLC Mask Partical Filtration Efficiency Tester ( PFE ) With PSL Test Aerosol

Ask Latest Price
Brand Name :
ZL
Model Number :
ZL-5066
Certification :
CE,ISO
Place of Origin :
China
MOQ :
1 set
Price :
Negotiable
Contact Supplier
PLC Mask Partical Filtration Efficiency Tester ( PFE ) With PSL Test Aerosol
PLC Mask Partical Filtration Efficiency Tester ( PFE ) With PSL Test Aerosol
PLC Mask Partical Filtration Efficiency Tester ( PFE ) With PSL Test Aerosol

Dongguan Zhongli Instrument Technology Co., Ltd.

Verified Supplier
7 Years
guangdong, dongguan
Since 2014
Business Type :
Manufacturer
Total Annual :
1 Million-2.5 Million
Employee Number :
100~150
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement