Touch Screen Xenon Lamp Aging Environment Test Chamber Programable Cycle Test
Main functions:
The samples exposed to high temperature are tested by light and humidity cycle to simulate dew and rain. The external conditions and components of the instrument deteriorate and damage in a few days or weeks, and the sun shading film, color change Including crack, crack, wrinkle, foam, paint, strength loss, oxidation, etc.
ZL-6011A xenon lamp weather-resistant testing mac...
Main feature:
Xenon lamp (vertical weather resistance) test case high quality electrostatic sprayed plastic or stainless steel container for cold rolled steel plate.The radiation source is a xenon lamp in the solar spectrum, which can automatically record the radiation intensity and correctly record the workbench temperature.Adjust the irradiation period, dark period and spray period.It can be adjusted according to relevant test standards or customer requirements.Select input touch screen control unit or intelligent digital controller.
Xenon lamp weatherability test chamber contains ultraviolet radiation sensor.It can change the change of light energy such as aging tube.Ultraviolet radiation sensors are permitted.The UV sensor keeps the radiation intensity within the working value by continuously monitoring the internal light and adjusting the performance of the tube.
Spray cycle can effectively simulate temperature change and rainfall erosion.Due to the good control of rainwater, the coating (including color and color) on the wood surface may be eroded.Therefore, the material is directly exposed to ultraviolet and underwater.The function of the shower reproduces this environmental condition and can improve the color and climate aging test.
Equipment summary:
Xenon lamp aging testing machine is a comprehensive climate testing machine, in addition to climatic aging test, the lightfastness of materials can be carried out to test, polymer materials exposed at simulated sunlight. It simulates the light, temperature, rainfall, condensing, humidity to test the materials; it can be used for choosing new materials, improving existing materials, or assessment of change in material composition;
Technical parameter:
Model | ZL-6011A | |
Testing room D×W×H | 500*600*500mm | |
Index | Temperature range | RT+10℃~80℃ |
Humidity range | 65~98%R·H | |
Spray time | 1~9999min, adjustable | |
Spray cycle | 1-240min, interval adjustable | |
spectral wavelength | 290nm~800nm(550w/m2) | |
light source | xenon lamp(air-cooled) | |
Xenon lamp power | 1kw,option: 1.8kw(longevity:1600H) | |
Temperature and humidity control | Time controller | Import controller from Moeller |
Accurate range | Temperature: ±0.1℃,/ humidity: ±0.1℃R·H | |
Sensor | Platinum resistance Pt100Ω/mv | |
Heating system | Independent system, nickel chromium alloy electric heating type heater | |
Humidity system | stainless steel, external Isolated humidifier | |
Blackboard temperature | Bimetal thermometer blackboard 55℃~75℃ | |
Water supply | Humidification water supply with automatic control, xenon lamp cooled by water recycling | |
Temperature controller | Import controller | |
humidity | Irradiation: 30%~65%RH darkly: up to 90%RH | |
Cycle system | low-noise air-conditioning-type motors, multi-leaf-type centrifugal wind wheel | |
Material | Outside material | Advanced spray color plate /SUS304 stainless steel |
Inside material | SUS304 stainless steel | |
Sample holder material | SUS304 stainless steel | |
nsulation | High and low temperature aging of silicone rubber | |
Standard | a set of radiation-proof glass window, dynamic testing sample shelf 1, xenon lamp tube 2 | |
Protector | Leakage, short circuit, over-temperature, water shortages, motor overheating, over-current protection. | |
Power | AC380V±10% 50±0.5HZ , Three-phase five-wire system | |
Environmental temperature | ±5℃~+30℃ ≤85%R·H |
Operating conditions:
1. Temperature:15℃~35℃
2. Relative humidity: less than 85%RH
3. Without strong vibration and strong electromagnetic field
4. Without high concentration of dust and corrosive materials in round field
5. No direct sunlight or other sources of heat radiation directly
6. Without a strong airflow around,when need forced air flow around,air should not be blown directly to the body
7. Test cases should be placed stably, level
8. The sides of the test chamber should keep a certain distance, convenient maintenance operation.
9. Installation site well ventilated
10. Ground Benign
Test chamber:
◆ This test box adopts an integrated structure. The upper left part of the box is the working room, the upper right part is the electrical control room, and the lower part is the compressor refrigeration unit. The sample rack mechanical speed device, the xenon lamp condensate tank, the water pump and other various implementing devices, electrical control The cabinet is placed on the right side of the test box for easy operation.
◆ The inner wall of the test box is made of SUS304# stainless steel plate.
◆ The insulation material of the box body is made of polyurethane foam and ultra-fine glass fiber, which has a good insulation effect. The outer surface of the test box is free from frost and condensation.
◆ There is a condensate drain at the bottom of the box
◆ The door frame adopts environmentally friendly silicone rubber sealing strip that can withstand high and low temperatures for a long time.
◆ There is a glass observation window on the front of the box, and there is a protective film on the window to prevent the eyes from being damaged by the xenon lamp.
Gas circulation part:
With built-in airway and circular fan, effective cooling and energy control is introduced to achieve an effective heat exchange of high fans, to improve the air flow, to achieve the goal of temperature change and to increase the air volume by adjusting the blue opening.The heat exchanging capacity of the air humidifier and cooler is heated and the uniformity of temperature and humidity is greatly improved.
Use environment:
Temperature: 5℃~+35℃
Humidity: ≤85%RH