Controlled Environment Chamber Aging Testing Machine Solar Radiation Test Chamber
Corresponding standard:
CNS-3556,JIS-K6301,ASTM-D2436,ASTM D1148
This tester is specially designed for rubber, plastic, paper and various insulation materials to do aging experiments, such as rubber, plastic industry, this machine is used to promote the deterioration of vulcanized rubber; testing to calculate the rate of change of tensile and elongation after the deterioration process at different temperatures and times, in the paper industry is used in the determination of the basis weight and moisture content of paper, etc.. It can study the aging law of rubber and plastic under the action of ozone, quickly identify the aging performance of vulcanized rubber, and provide the basis for improving the service life of rubber and plastic products. This machine conforms to many testing standards, such as GB, CNS, JIS, ASTM, ISO, IEC, UL, BS, etc.
1.1 Design Principle
In general sulfurized rubber products at a fixed temperature of 70 ℃ heating test time for a day (24HR) equivalent to the natural environment in six months of time deterioration.
1.2 Machine Features:
1.2.1. Adopt electronic temperature setter for adjusting and controlling temperature constant.
1.2.2. Three-stage heating control, the use of power to adjust the heating speed, reduce energy waste.
1.2.3. Adopt hot air circulation method and motor-driven rotary plate to ensure uniform heating temperature.
1.2.4. Equipped with exhaust fan and tray, which can adapt to different testing requirements.
1.2.5. Equipped with time setting controller and super high temperature protection device to ensure the safety of use and increase the accuracy of the test.
1.2.6. The test chamber adopts heat insulation and sealing assembly, heating up quickly, reducing errors and increasing safety.
1.2.7. The lighting is controlled by independent switch.
1.2.8. The observation window adopts multi-layer type reinforced glass.
1.2.9. It can be used as an oven to speed up the testing speed.
1.2.10. Simple operation, easy maintenance, reduce the preparation time before the test.
2. Specifications:
Type Special | 150L |
Test Space (L×W×H cm) | 50X50X60 |
External Dimensions (L×W×H mm) | 950×650×1450 |
Test Temperature(RT℃) | RT~250℃ |
Time Controller | 0~24hr / Specified |
Temperature Controller | Electronic type |
Electric Heater(KW) | Three stage 3.5KW |
Power Supply(V) | 220V |
Maximum Current(A) | 25A |
Machine Weight(kg) | 70 |
Motor Power(HP) | 1/8×1 |
Machine Weight(kg) | Static test flat plate×2 |
Dynamic turntable×1 |