Non-Induction Construction 0.68uf 684K 275VAC X2 Safety Capacitor Long Life Due To Self-Healing Effect
X2 Safety Capacitor.pdf
Characteristics of X2 Safety Capacitors
Non-inductive construction with metallized polypropylene film.
Excellent moisture resistance.
self-healing.
Excellent flame retardant properties.
Capable of withstanding overvoltage shocks.
The use of X2 safety capacitors.
Suppresses electromagnetic interference.
Jumper the lines.
It is suitable for the resistance-capacitance step-down of ammeters, LED drivers, controllers, etc. in series in the circuit.
Products Introduction
MPX are winded with metallized polypropylene film dielectric,Non-inductive construction, tinned copper wire leads,and flame retardant epoxy resin coating. They have excellent features of self-healing and good flame retardant according to UL 94-V0
Features
1 Non-induction construction
2 High moisture-resistance
3 Self-healing property
4 Flame retardant type(compliance with UL 94V-0)
5 Very small loss
Construction and main materials of products
Specifications(IEC 60384-14)
Test items | Performance requirements | Conditions of test |
Capacitance | Within the tolerance specified | 1KHz, 1Vrms Max. at 25℃ |
Dissipation Factor | 0.001 (0.1%) Max. | 1KHz, 1Vrms Max. at 25℃ |
Voltage proof | Shall be no abnormality | Between terminals 4.3UR (Vdc) Test of 60sec. |
Between terminal and enclosure UR×200%+1500Vac, 60sec. | ||
Insulation resistance | CR ≤ 0.33μF IR ≥ 15,000MΩ CR >0.33μF IR ≥6,000s | 100±15Vdc, 60sec / 25℃ |
Robustness of terminations | No wire breakage and no damage of capacitor | Tense Strength of Terminal Load Force : 1.0 Kg Holding Time : 10 ± 1sec |
Bending Strength of Terminal Load Force : 0.5 Kg Bending Time : 4 x 90 ゚ | ||
Resistance to soldering heat | (1) Appearance : No visible damage (2) △C/C : ≤ ±5% of the initial value | Solder temperature: 260±5℃ Solder time: 5±0.5sec |
Solderability | 95% of the surface tinning | Solder temperature: 260±5℃ Solder time: 2±0.5sec |
Rapid change of temperature | The capacitors shall be visually examined and there shall be no visible damage. | Lower category temperature: -40℃ Upper category temperature: 110℃ Number of cycles: 5 Duration t1 = 30 min |
Vibration | The capacitors shall be visually examined and there shall be no visible damage | Frequency range: 10~55Hz Course: X,Y,Z (axis) 2h / axis ( 6h in total) Displacement amplitude: 0.75mm |
Test items | Performance requirements | Conditions of test |
Climatic sequence | (1) Appearance : No visible damage (2) △C/C : ≤ ±5% of the initial value (3) DF ( tanδ) : ≤ 0.008 of increased value (4) IR : ≥ 50% of the applicable limits (5) Voltage proof : Normal | Dry Heat Upper Temperature: 110℃ Lower Duration: 16Hrs |
Cold Temperature: -40℃ Duration: 2Hrs | ||
Damp Heat Steady State | (1) Appearance : No visible damage (2) △C/C : ≤ ±5% of the Initial value (3) DF ( tanδ) : ≤ 0.008 of increased value (4) IR : ≥ 50% of the applicable limits (5) Voltage proof : Normal | +40°C and 93% RH, 56 days |
Charge and discharge | (1) Appearance : No visible damage (2) △C/C : ≤ ±10% of the initial value (3) DF ( tanδ) : ≤ 0.008 of increased value (4) IR : ≥ 50% of the applicable limits | Test voltage : √2 x URVAC 50 Hz Charge and discharge: 0.5sec/time Repeated for 10000 cycles |
Endurance | (1) Appearance : No Visible Damage (2) △C/C : ≤ ±10% of the initial value (3) DF ( tanδ) : ≤ 0.008 of increased value (4) IR : ≥ 50% of the applicable limits | 1.25 x UR VAC 50 Hz, once every hour increase to 1,000VAC for 0.1 second, 1,000 hours at upper rated temperature |
Storage conditions
1 t should be noted that the solderability of the terminals may be deteriorted when stored barely in an atmosphere for a long preriods
2 It shouldn't be located in particularly high temperature and high humidity, it must submit to the following conditions(keeping in the original package)
Temperature: 35 MAX Relative humidity:60% MAX
3 Storage period:Losse:12 monthes max (from the manufacturing date marked on the label in package bag)
Enviroment requirement
1 Compliance with the requirement of RoHS.
2 Compliance with the requirement of REACH.
3 Without Halogen(as required).
4 Please see the attachment 2 for the test reprots of the Rohs and Reach by a third party