Description:
It is a rapid quantitative analysis instrument for analyzing the composition of ferrous and non-ferrous metals. This instrument is widely used in metallurgy, machinery and other industrial sectors, online analysis before smelting furnace and product inspection of central laboratory, is one of the effective means to control product quality.
Power supply voltage: | 50Hz, 220V±1% |
Input power: | 1.0KVA |
Charging capacitor: | pre-ignition 7.5μF, exposure 1.5μF |
Peak current: | pre-combustion 120A, exposure 30A |
Main circuit peak pressure: | 300VDC (automatically adjust peak voltage) |
Pilot circuit: pulse amplitude: | +15KV |
Auxiliary gap: | using tunnel diode |
Discharge frequency: | digital light source 100Hz--1000Hz |
Sample stage analysis gap: | 4mm |
Argon-filled sample holder without water cooling | |
Analysis interval: | generally less than 1 minute |
Analysis of the band range: | 130-800nm |
Grating: | radius of curvature 750mm |
Scribe density: | 2400 lines/mm |
Scoring area: | 30×50mm2 |
Sparkling wavelength (level 1): | 300nm |
Line dispersion: | 0.55nm/mm |
Incident slit width: | 20μm |
Outlet slit width: | 50μm, 75μm |
Photomultiplier tube: | 28mm diameter, 10 side window tubes, fused silica or glass enclosure |
Maximum number of channels allowed: | 31 (expandable to 64 channels) |
Local constant temperature of spectrometer: | 35±0.2℃ |
Measurement and control system: | measurement and control by single board machine, data exchange with host computer |
Measurement method: | segmentation integral |
Integral capacitance: | 0.047μF |
Reproducibility: | RSD0.2% |
Photomultiplier tube high voltage power supply | Voltage: -1000V Stability: 8 hours better than 0.5% |
High pressure regulation: | from -550V to -1000V, 8 (0-7) adjustment |
High voltage settings: | users change through computer software |
Host: | length 1400mm × width 950mm × height 1100mm |
Weight: | 450kg |
main features
1, 750mm/1000mm focal length grating design, Pa-Longge device, high vacuum, high resolution, high sensitivity, etc.; because the machined grating can produce higher-order spectra, the line selection is more flexible, thus avoiding spectral interference.
2, the instrument structure design is reasonable, the electronic system uses international standard cage, high integrated circuit design, low failure rate.
3. The analysis speed is fast, the repeatability is good, and the stability is good.
4. Using a highly stable digital light source, the excitation frequency varies between 100-1000 Hz, different samples can be analyzed, and different excitation parameters can be selected to achieve the best analysis results.
5. Highly integrated acquisition and control system with high degree of automation.
6, the use of imported photomultiplier tube, with dark current, high signal to noise ratio, long service life and so on. .
7. The analysis scan process can scan all the elements at the same time. The scanning process is simple, and the deviation of each element relative to the base element can be quickly analyzed.
8. During the process of exciting the sample, there is no need to perform water cooling on the excitation stage, and continuous analysis of the sample can also achieve better data.
9. The measurement and control system adopts the measurement and control of the single board machine, and exchanges data with the host computer to improve the running speed.
10. The computer software is used to adjust the negative voltage of the photomultiplier tube of each channel, and the negative voltage of the channel is adjusted by 8 steps, thereby greatly improving the utilization of the channel and analyzing the optimal linear range of the spectral line in the analysis of different materials. Reduce the number of channels used and reduce costs.
11, can be used for a variety of matrix analysis: Fe, Co, Cu, Ni, Al, Pb, Mg, Zn, Sn and so on.
12, using the operating software under the pure Chinese Windows system, the operation is simple and easy to understand.
13. The computer software has a database system, which is convenient for querying and printing measurement data, and can also transmit data remotely through the network, which is convenient and quick.
14. Each system is independently powered and composed of units, which is easy to use and easy to maintain.
15. The optical part constant temperature measure is used to ensure the normal operation of the instrument, thus reducing the environmental requirements.
16. High-precision linear motor is used for seam scanning, which is fast and accurate.
17. Use the overall exit slit to increase the channel.
main technical psecifications
1. Excitation source:
(1) Power supply voltage: 50Hz, 220V±1
(2) Input power: 1.0KVA
(3) Charging capacitor: pre-ignition 7.5μF, exposure 1.5μF
(4) Peak current: pre-combustion 120A, exposure 30A
(5) Main circuit peak pressure: 300VDC (automatically adjust peak voltage)
(6) Pilot circuit: pulse amplitude: +15KV
Auxiliary gap: using tunnel diode
Discharge frequency: digital light source 100Hz--1000Hz
2, the excitation station
(1) Sample stage analysis gap: 4mm
(2) Argon-filled sample holder without water cooling
(3) Analysis interval: generally less than 1 minute
3, spectrometer
(1) Analysis of the band range: 130-800nm
(2) Grating: radius of curvature 750mm
Scribe density: 2400 lines/mm
Scoring area: 30×50mm2
Sparkling wavelength (level 1): 300nm
Line dispersion: 0.55nm/mm
(3) Incident slit width: 20μm
(4) Outlet slit width: 50μm, 75μm
(5) Photomultiplier tube: 28mm diameter, 10 side window tubes, fused silica or glass enclosure
(6) Maximum number of channels allowed: 31 (expandable to 64 channels)
(7) Local constant temperature of spectrometer: 35±0.2℃
4, measurement and control system
(1) Measurement and control system: measurement and control by single board machine, data exchange with host computer
(2) Measurement method: segmentation integral
Integral capacitance: 0.047μF
Reproducibility: RSD0.2%
(3) Photomultiplier tube high voltage power supply:
Voltage: -1000V
Stability: 8 hours better than 0.5%
High pressure regulation: from -550V to -1000V, 8 (0-7) adjustment
High voltage settings: users change through computer software
5, the size:
(1) Host: length 1400mm × width 950mm × height 1100mm
(2) Weight: net weight is about 450Kg