CAPACITIES (kg): 10, 20, 50, 100, 200, 300, 500.
OIML R60. C3 precision class.
Stainless steel. IP68 protection.
MAIN FEATURES
C3 PRECISION CLASS
STAINLESS STEEL
IP68 PROTECTION
MAX. CAPACITIES FROM 10 TO 500 kg
SHIELDED CONNECTION CABLE
OIML CERTIFICATE AVAILABLE UPON REQUEST
TEST CERTIFICATE AVAILABLE UPON REQUEST
TECHNICAL FEATURES
Minimum load cell verification interval: Vmin = EMax / 10.000
Maximum number of verification intervals: nLC= 3000
Full Scale Output: 2mV/V +/- 0,1%
Combined error: 0,017% of Full Scale Output (F.S.)
Non-Repeatability: 0,015% F.S.
Temperature effect on zero: +/- 0,002% /°C
Temperature effect on full scale output: +/- 0,0012% /°C
Compensated Temperature Range: –10°C/+40°C
Operating Temperature Range: –20°C/+60°C
Creep error after 30 minutes +/- 0,016% F.S.
Maximum tolerated excitation voltage: 15 VDC
Input Resistance: 385 ± 20 Ohm
Output Resistance: 350 ± 5 Ohm
Insulation Resistance: > 5000 MOhm
Safe Overload: 200% F.S.
Ultimate Overload: 300% F.S.
Nominal displacement: < 0,4 mm
4-wire shielded cable, 3m long, 4mm diameter.
ATEX VERSION
The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.
Wiring Code |
Colour | Function |
-- | SHIELD |
BLACK | OUTPUT + |
RED | INPUT + |
BLUE | OUTPUT - |
WHITE | INPUT - |
Force Load Cell Available versions
| Code | Max (kg) |
| FXC10 | 10 |
| FXC20 | 20 |
| FXC50 | 50 |
| FXC100 | 100 |
| FXC200 | 200 |
| FXC300 | 300 |
| FXC500 | 500 |