DALA F2030-K can be managed by computer ,cellphone and touch screen,like parameter setting ,measurement data management ,
and so on,customers can choose as their application request.
Model | F2030-K |
---|---|
Axis | 2-axis |
Measurement data | diameter and ovality, lump and necks |
Frequency | 10KHz(5KHz/axis/second) |
Measurement range | 0.5~30mm |
Repeatability(1) | ±0.2μm |
Accuracy(2) | ±(0.001+0.01%*D)mm |
Min defect height | 0.01mm |
Min defect length(3) | 0.4mm(wire speed120m/min) 1.6mm(wire speed500m/min) |
Size | 280*245*58mm |
Working power source | 24V ±10% 40VA |
Running temperature | 5℃~50℃ |
Display | LED display |
Commuincation port | Standard:WIFI,RS485 MODBUS RTU,CAN |
Electrical port | Standard: digital output(relay),digital input,analog input,encoder pulse input port Option:PI feedback control |
Data colletion & analysis | available (option DS14 ZT display and control system,DMS1000) |
Out-of-tolerance alarm | available |
Transparent mode | available |
Note:
(1) set sliding window as 100ms, outside diameter repeatability of φ1mm round rod at measurement center area
(2) set sliding window as 100ms, outside diameter deviation of φ1mm round rod at measurement area
(3)set defect measurement average time as 0ms, the minimum defect length which cannot be missed at the measurable area
(4)PI feedback control is option, but must order at placing order