40tons cooling tower technical parameters
Model |
STG-40 |
Basic parameter
|
Type |
Counter current circular cooling tower |
Nominal flow |
31.21m3/h |
Inlet/outlet temperature |
37℃/32℃ |
Dry-bulb temperature |
31.5℃ |
Wet-bulb temperature |
27℃ |
Cooling capacity |
156050kcal/h |
Noise (dB(A)) |
60dB(A) |
Power |
380V/3P/50Hz |
Water quality |
PH=6 to 8 |
N.W/G.W |
130kg/550kg |
Fan |
Fan type |
Axial Flow |
Cooling air flow(m3/h) |
18726m3/h |
Rotation speed(r/min) |
710r/min |
Diameter |
770 mm |
Quantity |
4 pieces/set |
Electronic box |
Water proof type |
Power |
1.5kw |
Start-up mode |
Direct start |
Size
|
Height × diameter(H×φ) |
2500×1600mm |
Inlet pipe caliber |
80mm |
Outlet pipe caliber |
80mm |
Full outlet/drain off pipe caliber |
25mm/25mm |
water supply pipe caliber |
15mm |
Material |
Sprinkler |
P.V.C-U |
Casing |
Fiberglass |
Water basin |
Fan |
Polyamide |
Electronic box |
Water proof type |
In -fill |
P.V.C. |
Shelf |
Hot-dip galvanized steel |
Product Description
- Cooling tower is a heat removal device that cools water vapor into cooler water, discharging waste heat from a system to the atmosphere.
- Cooling tower is a specialized heat exchanger in which air and water are brought into direct contact with each other in order to reduce the water’s temperature. As this occurs, a small volume of water is evaporated, reducing the temperature of the water being circulated through the tower.
-
Simple operation: as long as the circulating water system pump work, the product is in the working state.
-
Safe and easy to maintain: Because this product has no electric fan, it prevents the occurrence of electrical fire in operation.
-
It is safer to use places with flammable, explosive and other special requirements; Simple structure, convenient maintenance, low operating cost, no fan failure caused by the shutdown and production accident.
-
Wide use, flexible combination: This product has a variety of combination units, can be flexibly combined according to the site.
-
Air conditioning equipment and industrial processes can generate heat in the form of tons of hot water that needs to be cooled down. That’s where an industrial cooling tower comes in. Overheated water flows through the cooling tower where it’s recirculated and exposed to cool, dry air.
-
Heat leaves the recirculating cooling tower water through evaporation. The colder water then reenters the air conditioning equipment or process to cool that equipment down, and the cooling cycle repeats over and over again.
-
When the warm condenser goes into the cooling tower, the water is passed through some nozzles which spray the water into small droplets across the fill, which increases the surface area of water and allows for better heat loss thru greater evaporation.
-
The purpose of the fan on top of the water cooling tower is to bring in air from the bottom of the tower and move it up and out in the opposite direction of the warm condenser water at the top of the unit. The air will carry the heat through evaporating water from the cooling tower into the atmosphere.