100tons cooling tower technical parameters
Model |
STG-100 |
Basic parameter
|
Type |
Counter current circular cooling tower |
Nominal flow |
78.12m3/h |
Inlet/outlet temperature |
37℃/32℃ |
Dry-bulb temperature |
31.5℃ |
Wet-bulb temperature |
27℃ |
Cooling capacity |
390600kcal/h |
Noise (dB(A)) |
63.5dB(A) |
Power |
380V/3P/50Hz |
Water quality |
PH=6to 8 |
N.W/G.W |
500kg/1600kg |
Fan |
Fan type |
Axial Flow |
Cooling air flow(m3/h) |
46872m3/h |
Rotation speed(r/min) |
710r/min |
Diameter |
1450 mm |
Quantity |
4 pieces/set |
Electronic box |
Water proof type |
Power |
2.2kw |
Start-up mode |
Direct start |
Size
|
Height × diameter(H×φ) |
3300×2800mm |
Inlet pipe caliber |
100mm |
Outlet pipe caliber |
100mm |
Full outlet/drain off pipe caliber |
25mm/25mm |
water supply pipe caliber |
25mm |
Material |
Sprinkler |
P.V.C-U |
Casing |
Fiberglass |
Water basin |
Fan |
Al alloy |
Electronic box |
Water proof type |
In -fill |
P.V.C. |
Shelf |
Hot-dip galvanized steel |
Product Description
-
A cooling tower is a heat removal device that uses water to transfer process waste heat into the atmosphere.
-
Likewise, an industrial cooling tower operates on the principle of removing heat from water by evaporating a small portion of water that is recirculated through the unit. The mixing of warm water and cooler air releases latent heat of vaporization, causing the water to cool.
-
Cooling towers may release heat from water vapor by evaporation, cooling the working fluid to near the wet bulb temperature, or there are "closed circuit dry cooling towers,"
-
Stable temperature drop: Since the tower adopts the principle of injection for cooling, there is no packing blockage and fan damage. The advanced water suspension bearing technology ensures that the automatic rotation atomization device of the fan driven by water injection rotates flexibly and reliably, and ensures the long-term stable operation of the tower.
-
No special requirements for water quality, strong applicability: due to the use of the company's patented technology design, atomizing nozzle diameter of more than 10, not easy to plug, nozzle flow speed is large, difficult to scale, no special requirements for water quality. There is no filler, not easy to scale, reduce the possibility of clogging.
-
Quiet design, low noise: no motor, reducer and other rotating mechanical equipment, eliminate the disturbing noise of electric fan
-
Cooling towers are primarily used for heating, ventilation, and air conditioning (HVAC) and industrial purposes.
-
Cooling towers provide a cost-effective and energy efficient operation of systems in need of cooling.
-
Cooling towers are used in power plants, petroleum refineries, petrochemical plants, natural gas processing plants, food processing plants, and other industrial facilities.