Specifications
Brand Name :
Purescience
Model Number :
EMF100-8
Certification :
ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
Place of Origin :
China
MOQ :
5 sets
Price :
negotiable
Payment Terms :
T/T, L/C, Western Union
Supply Ability :
500 sets per month
Delivery Time :
3 weeks
Packaging Details :
carton
Product name :
wastewater flow transmitter
Material of Electrode :
Hastelloy-C, Ti, Ta, 316L
Liner material :
Hard rubber, PTFE
Flow velocity range :
1-15 m/s
Pressure rating :
PN16, PN25, PN40 Mpa
Accuracy :
0.5% R
Pipe Dia. :
DN25-DN300
Connect port :
Flange
Enclosure protection :
IP65
Power supply :
100-240 VAC / 18-36 VDC
Description

magnetic flow meter for wastewater flowmeter, Communication: Modbus RS485, pulse output

Application

Agricultural, irrigation, boiler feedwater, clean room, clean water, concrete , coolant, HVAC / R system monitoring, residential water monitoring, utilities, waste water, grey water

Grounding

From flow meter housing terminal G to grounding by minimal 1.6mm2 copper cable, resistivity < 10 Ω.

Key Features

  • Suitable to meter for wide range of conductive liquid media
  • Virtually no pressure loss
  • No Moving Parts
  • Flanges port connection
  • RS485 Standard
  • Suitable for Pipes diameter p to 2000 mm
  • Large meter ratio
  • High Accuracy
  • 4 to 20 mA / Frequency / Pulse output

Technical data

Product name

Electromagnetic flowmeter

Product type

Local|compact display

Remote display

Signal converter

Model

IYF-E

IYF-F

IRT

Pipe Diameter (mm)

DN10-DN2000

Power supply

100-240 VAC / 18-36 VDC

Accuracy

+ 0.5%

+ 0.5%

+ 0.5%

Power consumption

<6w

<6w

<6w

Enclosure rating

IP65

IP68

IP65

Liquid temperature

-25-120℃

-25-120℃

-25-120℃

Ambient temperature

-25-50℃

-25-50℃

-25-50℃

Relative humidity

10-90%

10-90%

10-90%

Meter ratio

1:100

1:100

1:100

Flow direction

Bi-direction flow

Bi-direction flow

Bi-direction flow

Communication

RS485 / Bacnet

RS485 / Bacnet

RS485 / Bacnet

Signal Output

4-20mA/Pulse/Frequency

4-20mA/Pulse/Frequency

4-20mA/Pulse/Frequency

Accuracy

Pipe Dia (mm) Velocity (m/s) Accuracy
3-20 <0.3 + 0.25% FS
0.3-1 + 1.0% Readout
1-15 + 0.25% Readout
25-600 0.1-0.3 + 0.25% FS
0.3-1 + 0.5% Readout
1-15 + 0.3% Readout
700-3000 <0.3 + 0.25% FS
0.3-1 + 1.0% Readout
1-15 + 0.25% Readout

Selection guide

I

Model

YF

Electromagnetic flowmeter

TF

Turbine

VF

Votex

LX

Vane wheel

T

Ultrasonic

E/F display mode

E: compact/local display, F: remote display

Pipe Dia

Type (mm)

xxxx

15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400,

500, 600, 800, 1000

Code

Accuracy

1

+ 0.5% FS

2

+ 1.0% FS

3

+ 0.2% FS

Code

Type

N

Converter: 12 / 24 VDC, pulse output

A

Transmitter: 24VDC, 4-20mA outpt

B

Intelligent, Lion battery, no local display

G

Smart, local display, 4-20mA output

C1

Smart, local display, RS485

C2

Smart, local display, HART

Code

Type

S

Carbon steel housing

L

Stainless steel housing

G

High pressure housing

HL

316L electrode

HTi

Titanium electrode

HTa

Tantlum electrode

HC

Hastelloy-C electrode

L1

Liquid media

L2

Gas media

P

Pressure compensation

T

Temperature compensation

PT

Pressure&Temp. Compensation

F

PTFE liner

X

Rubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing,

smart, 4-20mA outpt, RS485, 316L electrodes, liquid media meter, PTFE liner

Pipe Diameter, flow volume and product dimension

Dia

Flow volume (m3/h)

Product dimension (mm)

(mm)

Normal

Min

Max

L

D

H

H1

15

1.5

0.06

9.5

150

95

272

254

20

2.5

0.11

16.9

105

277

254

25

3.5

0.18

26.5

115

283

254

32

6

0.29

43.6

140

297

270

40

10

0.45

67.8

150

307

280

50

15

0.71

106.0

200

165

318

294

65

25

1.19

179.1

185

337

313

80

40

1.81

271.4

200

352

326

100

60

2.83

424.1

250

220

371

344

125

100

4.42

665

250

401

372

150

135

6.36

954

300

285

431

403

200

250

11.3

1696

350

340

486

460

250

375

17.66

2650

400

395

547

511

300

540

25.43

3817

450

445

597

565

350

735

34.62

5195

505

657

620

400

960

45.22

6785

500

565

717

675

450

1200

57.23

8588

550

615

757

727

500

1500

70

10602

600

670

817

782

600

2160

100

15268

780

917

782

700

2950

138

20781

700

895

1027

1068

800

3850

180

27100

800

1015

1137

1157

Industrial applications

Chemical

Food & beverage

Paper mill

Metallurgy

Environment protection

Hydraulic

Mining

Stainless

Petroleum

Pharmacy

Air conditioner

Effluent treatment plant

Seawater desalination

Pharmacy

Water treatment

Competitive advantage

  • Compliance to international standards: ISO14001, GB/T28001, ISO9001-2008 / GB/T50430
  • Strict process control
  • Advanced calibration equipment
  • Engineer team

Send your message to this supplier
Send Now

Pulse Output Wastewater Flow Meter 1-15 M / S Flow Velocity Range Rs485 Standard

Ask Latest Price
Brand Name :
Purescience
Model Number :
EMF100-8
Certification :
ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
Place of Origin :
China
MOQ :
5 sets
Price :
negotiable
Contact Supplier
Pulse Output Wastewater Flow Meter 1-15 M / S Flow Velocity Range Rs485 Standard

Shanghai Xunhui Environment Technology Co., Ltd.

Active Member
10 Years
shanghai, shanghai
Since 2007
Business Type :
Manufacturer, Distributor/Wholesaler, Trading Company
Total Annual :
15 million-20 milliion
Employee Number :
100~120
Certification Level :
Active Member
Contact Supplier
Submit Requirement