Specifications
Brand Name :
Purescience
Model Number :
YE-TUF2000FP
Certification :
ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
Place of Origin :
China
MOQ :
5 sets
Price :
USD150-USD900
Supply Ability :
500 sets per month
Delivery Time :
3 weeks
Packaging Details :
carton
Product name :
Ultrasonic flowmeters
Type :
Inline | pipe type
Accuracy :
+/- 1% FS
Operation :
Key boards
Output signal :
4-20 mA / OCT pulse / relay
Input :
3-way 4-20 mA (temperature, pressure and level)
Media temperature :
-30 - 160 ℃
Work temperature :
Converter: -20 - 60 ℃ ; Transducer: -30 - 160 ℃
Pipe diameter :
15 mm - 6000mm
Pipe mount Material :
weld steel, stainless steel, cast iron, copper / brass, cement pipe, aluminum
Description

Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment

Principle of operation

This doppler inline ultrasonic flow meter, employs the frequency shift, that's the Doppler Effect, of an ultrasonic signal when it is reflected by suspended particles or gas bubbles (can be discontinusely) in motion. A metering technology uses the physical phenomenon of a sound wave which changes frequency when it is reflected by the moving discontinuities in a flowing liquid. The ultrasonic sound is transmitted into a pipe with flowing liquids, and the discontinuities reflect the ultrasonic wave with a slightly different frequency that is directly proportional to the rate of flow of the liquid (Figure 1). Current technology requires that the liquid contain at least 100 PPM of 100 micron or larger suspended particles or bubbles.

Data sheet

Items Performance & Parameter
Convertor Principle Transit-time ultrasonic flow meter
Accuracy + 1%
Operation 4 keyboards operation
Output signal 1 channel 4-20mA, resistance 0-1K , accuracy 0.1%
1 way OCT pulse (Pulse width: 6-1000ms, default: 200ms)
1 channel relay output
Input signal 3 way 4-20mA, accuracy: 0.1%, (temp., pressure, level)
Temperature transducer Pt100, heat / energy measurement
Communication Galvanic isolation RS485, software upgrade by PC, MODBUS
Signal cable Twisted-pair cable, 50m; RS485, transmission distance 1000m or above.
Connect port Pipe material Steel, stainless, cast iron, copper, cement, PVC, aluminum, etc
Pipe Dia 15 - 6000 mm
Straight pipe Upstream: 10xDia, or downstream: 5xDia, and 30xDia from pump
Metering Liquid type

Single sonic wave transmittable liquid, such as municipal water, cooling

water,

seawater water, waste water, pure water, Sewage with particle content, such

as oil, crude oil, lubrication oil, diesel oil, fuel oilChemicals, petrochemicals,

heating, ventilation ,air conditioner, power plants,

Temperature -30-160℃
Turbidity Up to 10000 ppm and less bubble
Flow velocity 0-7 m/s
Work environment Temperature Convertor: -20-60 ℃, Transducer: -30-160℃
Humidity Convertor: 85%RH, Transducer: submersible up to depth 2m
Power supply DC8-36V or AC10-30V / 1.5W
Dimension Convertor: 95*95*35mm

Features:

  • Non-Intrusive, transducer for Most Pipes from DN32 to DN6000mm
  • Inline pipe type , insertion type or clamp on probe transducer for options
  • Wide Measuring Range of 0.05 to 9 mps
  • ±2% of Calibrated Span Accuracy
  • Configuration and Total Stored in SD
  • Protection IP65 for housing, IP68 for transducer

Metering Diagram

Flow measurement Heat measurement

Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water TreatmentDoppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment

Reference chart

Type

Model

Pipe dia (mm)

Temperature

Dimension (mm)

Clamp on

TS-2

DN15-100

-30-90℃

45x25x32

TM-1

DN50-700

-30-90℃

64x39x44

TL-1

DN300-6000

-30-90℃

97x54x53

Clamp on (high temperature)

TS-2-HT

DN15-100

-30-90℃

45x25x32

TM-1-HT

DN50-700

-30-90℃

64x39x44

TL-1-HT

DN300-6000

-30-90℃

97x54x53

Insertion type

TC-1

DN80-6000

-30-90℃

190x80x55

TC-2(lengthen)

DN80-6000

-30-90℃

335x80x55

Pipe type

G3 (π type)

DN15-25

-30-160℃

G2

DN32/DN40

-30-160℃

G3

DN50-6000

-30-160℃

Optional temperature transducer

Specification

Model

Dia

Temp.

Water cut

Accuracy

Clamp-on temp. transducer Pt100

CT-1

>DN50

-40-160℃

No

100+ 0.8℃

Insertion temp. Transducer Pt100

TCT-1

Yes

Insertion temp. Pt100 with pressure

PCT-1

No

Insertion temp.Pt100 for small pipe D

SCT-1

<DN50

Yes

Industries

  • Chemicals
  • Petrochemicals
  • Oil & Gas
  • Heating, Ventilation & Air Conditioning (HVAC)
  • Power Plants
  • Water treatment

Applications

  • Metering of cooling water
  • Demineralisedwater
  • Control of batching and blending operations
  • Mass flow measurement
  • Allocation measurement
  • District heating
  • Irrigation
  • Energy measurement

Model Selection

I

Model

YF

Electromagnetic flowmeter

TF

Turbine

VF

Votex

LX

Vane wheel

T

Ultrasonic

E/F display mode

E: compact/local display, F: remote display

Pipe Dia

Type (mm)

xxxx

10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300,

400, 500, 600, 800, 1000

Code

Accuracy

1

+ 0.5% FS

2

+ 1.0% FS

3

+ 0.2% FS

Code

Type

N

Converter: 12 / 24 VDC, pulse output

A

Transmitter: 24VDC, 4-20mA outpt

B

Intelligent, Lion battery, no local display

G

Smart, local display, 4-20mA output

C1

Smart, local display, RS485

C2

Smart, local display, HART

Code

Type

S

Carbon steel housing

L

Stainless steel housing

G

High pressure housing

HL

316L electrode

HTi

Titanium electrode

HTa

Tantlum electrode

HC

Hastelloy-C electrode

L1

Liquid media

L2

Gas media

P

Pressure compensation

T

Temperature compensation

PT

Pressure&Temp. Compensation

F

PTFE liner

X

Rubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F,

Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt,

RS485, 316L electrode, liquid media meter, PTFE liner

Competitive Advantage:

  • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
  • CE approval
  • Strict process control
  • Advanced calibration equipment
  • Engineer team

Calibration

Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment

Work shop

Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment

Send your message to this supplier
Send Now

Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment

Ask Latest Price
Brand Name :
Purescience
Model Number :
YE-TUF2000FP
Certification :
ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
Place of Origin :
China
MOQ :
5 sets
Price :
USD150-USD900
Contact Supplier
Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment
Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment
Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment

Shanghai Xunhui Environment Technology Co., Ltd.

Active Member
10 Years
shanghai, shanghai
Since 2007
Business Type :
Manufacturer, Distributor/Wholesaler, Trading Company
Total Annual :
15 million-20 milliion
Employee Number :
100~120
Certification Level :
Active Member
Contact Supplier