the feature for AL-40S is as below:
1, Unique Fresnel lens, effectively increase the sensitivity
2, pet immunity
3, key components are imported from Japan, such as Japan made relay which can do ON/OFF for 1billion times
4, a under window which can reduce the blind detect area
5, with bracket
1. SPECIFICATIONS
MODEL | AL-40S |
Detection Range | 40ft x 56ft (12mx17m) |
Input Voltage | 10 ~ 16VDC |
Current Drain | 25mA(max.) at 12VDC |
Pyro Type | Dual Element |
Pulse Count | Qualified Motion Analysis - 2 or 4,Selectable |
Warm- up Period | Approx. 45 sec |
Alarm Period | Approx. 2.5 sec |
LED Indicator | Red Alarm LED(Selectable On / Off) |
Alarm Output | N.C., 24V DC 0.5A max. |
Tamper Output | N.C.,Open when cover is removed. 30V DC,0.5A max. |
Mounting Height | 6.5 ~ 8.5 ft (2~2.6m) |
Operating Temp. | 14°F ~ 131°F (- 10℃~55℃) |
Environmental | 95% max. |
Weight | 3.0 oz (83.5g) |
Dimensions | 3.9"Hx2.5"Wx1.7"D (98.0x64.0x43.0mm) |
2. DIMENSIONS
4. DETECTION PATTERN
8. TROUBLE SHOOTING AND MAINTENANCE
TROUBLE | TROUBLE CAUSE | REMEDY |
Unit does not power up. | No or low input power. | Apply proper input voltage. |
Input power polarity reversed. | Correct wiring polarity. | |
Alarm LED does not light. | LED jumper is set to “LED OFF”. | Set LED jumper to “LED ENABLE”(See Section 3). |
Incorrect sensor mounting height. | Increase /decrease mounting height. | |
Pulse Count setting incorrect for secured area. | Set pulse count jumper to suit the required detection characteristics. | |
Alarm LED/Relay triggers with out movement in detection area. | Unsecured environment:Animals / rodents in detection area . | Block access of animals / rodents. |
Heater/air conditioning equipment in sensor view. | Re-aim sensor. | |
Direct sun or headlights in sensor view. | Add curtain/shade to block light sources. | |
LED indicates alarm, no alarm output. | Incorrect wiring at alarm output terminals. | Correct wiring fault. |
Lightning damage. | Replace sensor. | |
Alarm LED on constantly, no fault in protected area or wiring. | Defective unit. | Replace sensor. |
Unit continues to operate after the input power has been disc- onnected. | The wire to the “ - ” power input was disconnected, the“ + ” is still connected. The power can now find a return path through the Alarm Output protection device and alarm wiring. |
Disconnect wire from the “ + “ power input. |
MAINTENANCE
INSPECTION:An inspection of this unit should be made periodically,consisting of,but not limited to all mounting,wiring,and the condition of the interior area and components.
CLEANING: Clean the plastic parts of this unit with a soft , clean , cloth dampened with water.
TESTING: This unit should be tested routinely for proper operation. At a minimum,operation should be fully checked yearly.
NOTES: This detector is designed to be incorporated into an alarm system. As it is part of a system, ALEPH cann’t assume responsibility for theft or damage if the system fails to operate.