INDOOR DUAL PASSIVE INFRARED DETECTOR
MODEL | DM-360 |
Detection Range | Coverage10m diameter (Mounting height 3m) |
Input Voltage | 10〜16V DC |
Operating Current | 20mA(max.) |
Sensitivity | 2°C(0. 6m/sec) |
Warm-up Period | 35±5sec |
Alarm Period | 2.0±0.5sec |
LED Indicator | Red Alarm LED(Selectable On/Off) |
Alarm Output | N.C., 20V DC 100mA max. |
Tamper Output | N.C.,Open when cover is removed. 30V DC,0.5A max. |
Mounting Height | 7.8 〜11.8ft (2.4〜3.6m) |
Operating Temp. | 14°F ~ 131°F (-10C〜55C) |
Environmen Hum | 95% max. |
Weight | 4.2 oz (121g) |
Dimensions | 4.72"DIA.x1.61" H (120mmDIA.x41mm H) |
TROUBLE | TROUBLE CAUSE | REMEDY |
Unit does not power up. | No or low input power. | Apply proper input voltage. |
Input power polarity reversed. | Correct wiring polarity. | |
Alarm LED does not light. | LED jumper is set to “LED OFF”. | Set LED jumper to “LED ENABLE”(See Section 2). |
Incorrect sensor mounting height. | Increase /decrease mounting height. |
TROUBLE | TROUBLE CAUSE | REMEDY | ||
Alarm LED/Relay triggers without movement in detection area. | Unsecured environment:Animals / rodents in detection area . | Block access of animals / rodents. | ||
Heater/air conditioning equipment in sensor view. | Re-aim sensor. | |||
Direct sun or headlights in sensor view. | Add curtain / shade to block light sources. | |||
LED indicates alarm, no alarm output. | Incorrect wiring at alarm output terminals. | Correct wiring fault. | ||
Lightning damage. | Replace sensor. | |||
Alarm LED on constantly, no fault in protected area or wiring. | Defective unit. | Replace sensor. | ||
Unit continues to operate after the input power has been disc-onnected. | The wire to the “ - ” power input was disconnected, the“ + ” is still connected. the power can now find a return path through the Alarm Output protection device and alarm wiring. | Disconnect wire from the “ + “ power input. |
8. NOTES
1. The product shall be installed indoor and do not use it under the following conditions.
① In the place where it is likely to be exposed to dust, high humidity,high temperatures,or rain.
② In the place where it is closed to magnetic field.
③ In the place where vibration or shock is directly transmitted to the product.
2. In order to ensure the normal operation of the product. It should be cleaned and maintained regularly.
① Please power off before cleaning the product.
② Do not use chemical detergents to clean the product.
3. Never disassemble, repair and modify the product.
4. The product comply with the SJ/T11363-2006 Standard and requirements of RoHS.
5. Specifications and design are subject to change without prior notice.