Airport X Ray Baggage Scanner Tunnel Size 1m*1m, X-ray Screening System
Assembly Instruction:
Step1:Connect the LCD monitor on console.
Step2:Connect to the power with the power supply plug for x ray scanner.
Step3: Connect the baggage receiving tray
Specifications: | |
Model Number | SF100100 |
Passageway Size | 1000(W)*1000(H) mm |
Penetration | mm Steel plate |
Belt Max Load: | 200Kg |
Dose per inspection: | <2Gy/h |
Resolving power | 38AWG |
Film Safety | Guarantee ISO1600 Film |
X-Ray leakage | <0.2µGy/h |
Ray beam spread angle | 80 degree |
Tube Voltage | 150-200KV |
Tube power | 1-1.5mA |
Cooling/work Cycle | Sealed Oil Cooling /100% |
Multi-energy/Distinguish objects | organic objects in orange,inorganic objects in blue,mixture in green |
Belt speed | 0.22m/s (adjustable) |
Display | HD 19’’LCD display |
High-energy/low energe | Two kinds of energyswitch display |
Image restoration | Image display restore the origional status |
X-ray control
Before maintaining this part, please eliminate all failures that related to power supply and system control. There are two kinds of failures concerning the X-ray control.
Failure 1: X-ray source does not emit X-ray
Probable reasons:
(1) There are no articles in the tunnel, or the articles have not blocked the light barrier.
(2) The cover plate on which the interlock switch is installed is open.
(3) The power plug of X-ray source controller is not inserted in the socket.
(4) The AC contactor is broken.
(5) The X-ray source is broken.
(6) The X-ray source controller is broken.
(7) The cable of X-ray source is not properly connected.
(8) The light barrier is not properly connected.
(9) The light barrier is broken.
X-ray security inspection systems User manual
- 35 -
(10) The driving roller has not started.
(11) The electronic controller is broken.
Solutions:
(1) Put large and light-tight articles in the tunnel.
(2) Cover the cover plate in the position of interlock switch.
(3) Plug in the power plug of X-ray source controller.
(4) Change the AC contactor KM2.
(5) Change the X-ray source.
(6) Change the X-ray source controller.
(7) Reconnect the cable of X-ray source.
(8) Check the cable of light barrier and connect it correctly.
(9) Change the light barrier.
(10) Start the driving roller.
(11) Change the electronic controller.
Failure 2: The X-ray indicator does not light
Probable reasons:
(1) X-ray has not emitted.
(2) Electronic control panel is broken.
(3) The cable is not properly connected.
(4) The indicator is broken.
Solutions:
(1) Put the articles on the Conveyor belt, and start the roller to emit the X-ray
(2) Change the electronic control panel
(3) Check the cable and connect it correctly
(4) Change the indicator
Note:
1)TIP function: to check if the operation work carefully and find out the Dangerous article as setting. The function can be open or close as requirement.
2) The scanning pictures can be zoom in, zoomout and moved around as you like. What’s more the pictures are in JPG format, can copy to any where to check.
3)Automatic start-stop motor control, when there is baggage on conveyor, it will run, while none, it will stop.