SPECIFICATIONS
Measuring principle:Potentiometric
Application:Measuring cable for contactless, inductive, digital transmission of measurement signals
Installation:Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
Characteristic:Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion
Measurement range:High impedance cable not necessary
Design:Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity
Material:Cable sheath: TPE;Junction box: aluminum
Dimension:Diameter: 6.3 mm (0.25 inch);Cores: 2x2 cores, twisted pairs;Length: up to approx. 100 m (328 ft)
Process temperature:-25 to 135 °C (-13 to 277 °F)
Process pressure:max. 50 bar/725 psi at 135°C/275°F.
Temperature sensor:For digital sensors with inductive plug-head with and without temperature sensor
Ex certification:ATEX II 1G Ex ia IIC T3/T4/T6;FM, CSA IS Cl.1 Div 1 Gr. A-D;ATEX, NEPSI II 3G Ex nL IIC;TIIS
Ingress protection:IP68
Additional certifications;Also available as TÜV approved SIL version
Field of application
CYK10 guarantees absolute water-proof connection of Memosens sensors to the transmitter. Its inductive coupling shows no contact corrosion and guarantees galvanic isolation of transmitter and medium. Simply forget about limited cable length, interfering potentials or moisture and benefit from completely safe and reliable signal transmission.
The Memosens data cable CYK10 is applied in Memosens systems measuring the following parameters:
pH/ORP
Dissolved oxygen (amperometric)
Conductive conductivity
Disinfection
Maximum process safety through non-contact, inductive and digital signal transmission: No contact corrosion, absolutely watertight, no interference potential.
Increased availability of the measuring point: Digital data transmission provides an automatic error message if the signal is lost.
More flexibility in plant planning and installation: Cable length up to 100 m is possible.
Approved for hazardous area use.
Related Part Number:
FDU91-RG1AA |
FDU91-RG2AA |
COS61-A1F0 |
CUS71D-AA1A |
FMU42-APB2A22A |
FMU90-R11CA111AA3A |
FMU90-R11CA131AA3A |
COM253-WX0005 |
COS61D-AAA1A3 |
CPS11D-7BT2G |
FMU41-ARB2A2 |
FMU30-AAHEAAGGF |
CPS11D-7AA21 |
CPS71D-7TB21 |
CPS12D-7NA21 |
CPM223-PR0005 |
CUS52D-AA1AA3 |
FTL31-AA4U3BAWSJ |
CPS11D-7AS21 |
COS61-A2F0 |
CPS12D-7PA21 |
CPF81D-7LH11 |
CPS11D-7BA2G |
CPM253-PR0005 |
51518598 |
CM42-MEA000EAZ00 |
CUS51D-AAD1A3 |
CM442-AAM2A2F010A |
CM442-AAM1A2F011A+AK |
CYK10-G101 |
CYK10-G051 |
COY31-Z |
FMU30-AAHEABGHF |
COS61D-AAA1A4 |
CYK10-E051 |
CPS71D-7TB2G |
CLM253-CD0005 |
CM442-AAM1A2F010A |
FTW31-A2A5AA0A+1 L:600MM |
CPS31-1AC2ESA |
CPS31-1EC2ESA |
DK9CM-2 |
FTL41-AAA2AAAAA2CJAAAAJ L=1000MM |
CPS11-2AA2ESK |
FTM51-AGJ2L4A12AA L=2600MM |
PMP71-AAA2H21GAAAA |
CLM253-ID0005 |
COV45-41TN1 |
CPS11-2BA2ESA |
CPS77E-BA6BBU2 |
CLM223-CD0520 |
CPM253-MR8010 |