General specifications |
||
---|---|---|
Switching function |
2 x normally open (NO) |
|
Output type |
PNP |
|
Rated operating distance |
3 mm |
|
Installation |
flush mountable |
|
Output polarity |
DC |
|
Assured operating distance |
0 ... 2.3 mm |
|
Actual operating distance |
2.6 ... 2.6 mm typ. |
|
Reduction factor rAl |
0.5 |
|
Reduction factor r304 |
1 |
|
Reduction factor rSt37 |
1.1 |
|
Output type |
3-wire |
|
Nominal ratings |
||
Operating voltage |
10 ... 30 V DC |
|
Switching frequency |
0 ... 500 Hz |
|
Hysteresis |
typ. 5 % |
|
Reverse polarity protection |
all connections |
|
Short-circuit protection |
pulsing |
|
Voltage drop |
≤ 3 V |
|
Operating current |
0 ... 200 mA |
|
Off-state current |
0 ... 0.5 mA typ. 0.1 µA at 25 °C |
|
No-load supply current |
≤ 25 mA |
|
Time delay before availability |
≤ 500 ms |
|
Operating voltage indicator |
LED, green |
|
Switching state indicator |
LED, yellow |
|
Functional safety related parameters |
||
MTTFd |
870 a |
|
Mission Time (TM) |
20 a |
|
Diagnostic Coverage (DC) |
0 % |
|
Compliance with standards and directives |
||
Standard conformity |
|
|
|
EN 60947-5-2:2007 |