Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 2-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0037X, Equipment protection level Gb: IECEx PTB 11.0037X, Equipment protection level Da: IECEx PTB 11.0037X, Equipment protection level Mb: IECEx PTB 11.0037X
Technical Data
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 5 mm | |
Installation | flush | |
Assured operating distance | 0 ... 4.05 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 kΩ) | |
Switching frequency | 0 ... 500 Hz | |
Hysteresis | 1 ... 10 typ. 5 % | |
Current consumption |
| |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | ≤ 1 mA |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
MTTFd | 4566 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity |
| |
| NAMUR | EN 60947-5-6:2000 |
| Standards | EN 60947-5-2:2007 |
Approvals and certificates | ||
IECEx approval |
| |
| Equipment protection level Gb | IECEx PTB 11.0037X |
| Equipment protection level Da | IECEx PTB 11.0037X |
| Equipment protection level Mb | IECEx PTB 11.0037X |
ATEX approval |
| |
| Equipment protection level Gb | PTB 00 ATEX 2048 X |
| Equipment protection level Da | PTB 00 ATEX 2048 X |
UL approval | cULus Listed, General Purpose | |
CCC approval |
| |
| Hazardous Location | 2020322315002255 |
NEPSI approval |
| |
| NEPSI certificate | GYJ16.1393X |
CML approval | on request | |
ANZEx | 18.3018X | |
KCC approval |
| |
| Hazardous Location | 19-AV4BO-0227 |
Marine approval | DNVGL TAA00001A5 | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable | |
Housing material | PBT/PPS | |
Sensing face | PBT | |
Degree of protection | IP66 / IP68 | |
Cable |
| |
| Cable diameter | 6 mm ± 0.2 mm |
| Bending radius | > 10 x cable diameter |
| Material | PVC |
| Core cross section | 0.75 mm2 |
| Length | 2 m |
Dimensions |
| |
| Length | 39 mm |
| Diameter | 18 mm |
General information | ||
Use in the hazardous area | see instruction manuals |
Related Models:
KCD2-SCD-EX1 | KFU8-UFT |
KCD2-STC-EX1.20 | K-HM26-2M-261533 |
KFD2-SR2-Ex1.W.LB | NBB15-U1-E2 |
KFD2-SR2-2.W.SM | NBB1,5-5GM25-E2 |
KFD2-SR2-Ex2.W.SM | NBB1,5-5GM25-E2-V3 |
KFD2-SR2-Ex2.2S | NBB1,5-F79-E0 |
KFD2-SR2-2.2S | NBB1,5-F79-E2 |
KFA6-DWB-EX1.D | NBB15-U1-Z2 |
KFA6-SR2-Ex2.W | NBB5-18GM50-E2-V1 |
KFA6-SR-2.3L.FA | NBB15-30GM30-E2-V1 |
KFA6-ER-1.5 | NBB15-30GM50-A2-V1 |
NBB15-30GM50-E2 | |
KFA6-ER-1.W.LB | NBB15-30GM50-E2-M |
KFA6-ER-2.W.LB | NBB15-30GM50-E2-V1 |
NBB15-30GM50-E2-V1-M | |
KFA6-SR-2.3L.FA | NBB8-18GM30-E2 |
KFA6-STR-1.24.4 | NBB8-18GM30-E2-V1 |
KFD0-CS-Ex1.50P | NBB8-18GM60-A2-V1 |
KFD2-SH-Ex1.T.OP | NJ4-12GK-SN |
KFD2-SL2-EX2.B | NJ5-18GK-N |
KFD2-SR2-EX1.W | NJ5-18GK-N-150 |
KFD2-SR2-Ex2.W | NJ5-18GM-N |
KFD2-STC5-1.2O | NJ8-18GK-N |
KFD2-STC5-Ex1 | RD0-FB-EX4 |
KFD2-STC5-Ex1.H | RD0-TI-Ex8.FF.* |
HIC2031 | Z787.F |