General specifications |
||
---|---|---|
Switching function |
Normally closed (NC) |
|
Output type |
NAMUR, bistable |
|
Inside diameter |
15 mm |
|
Measuring cylinder |
Fe-metal |
|
|
Diameter |
3 mm |
|
Length |
4 mm |
Passage speed |
≤ 10 m/s |
|
Output type |
2-wire |
|
Nominal ratings |
||
Nominal voltage |
8.2 V (Ri approx. 1 kΩ) |
|
Operating voltage |
5 ... 25 V |
|
Hysteresis |
typ. 1 % |
|
Reverse polarity protection |
reverse polarity protected |
|
Current consumption |
|
|
|
Traverse B |
3 mA |
|
Traverse A |
1 mA |
Time delay before availability |
≤ 5 ms |
|
Functional safety related parameters |
||
MTTFd |
2240 a |
|
Mission Time (TM) |
20 a |
|
Diagnostic Coverage (DC) |
0 % |
|
Compliance with standards and directives |
||
Standard conformity |
|
|
|
NAMUR |
EN 60947-5-6:2000 |
|
Standards |
EN 60947-5-2:2007 |
Approvals and certificates |
||
ATEX approval |
|
|
|
Equipment protection level Gb |
PTB 99 ATEX 2128 X |
FM approval |
|
|
|
Control drawing |
116-0165 |
UL approval |
cULus Listed, General Purpose |
|
Ambient conditions |
||
Ambient temperature |
-20 ... 70 °C (-4 ... 158 °F) |
|
Storage temperature |
-40 ... 100 °C (-40 ... 212 °F) |
|
Mechanical specifications |
||
Connection type |
cable PVC , 2 m |
|
Core cross section |
0.14 mm2 |
|
Housing material |
PBT |
|
Degree of protection |
IP67 |
|
Cable |
|
|
|
Bending radius |
> 10 x cable diameter |
Dimensions |
|
|
|
Height |
32.5 mm |
|
Width |
25 mm |
|
Length |
20 mm |
General information |
||
Use in the hazardous area |
see instruction manuals |