Technical Data | |
General specifications | |
Switching function | Normally closed (NC) |
Output type | NAMUR |
Rated operating distance | sn 2 mm |
Installation | flush |
Assured operating distance | sa 0 ... 1.62 mm |
Reduction factor rAl | 0.25 |
Reduction factor rCu | 0.2 |
Reduction factor r304 | 0.7 |
Output type | 2-wire |
Nominal ratings | |
Nominal voltage | Uo 8.2 V (Ri approx. 1 kΩ) |
Switching frequency | f 0 ... 1000 Hz |
Hysteresis | H 0.01 ... 0.1 mm |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
Current consumption | |
Measuring plate not detected | ≥ 3 mA |
Measuring plate detected | ≤ 1 mA |
Functional safety related parameters | |
Safety Integrity Level (SIL) | SIL 2 |
MTTFd | 11775 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0% |
Dimensions