Adhere to efficiency and energy conservation, process energy conservation, energy conservation of the whole plant, and "saving" as much as possible to help enterprises to save energy and increase efficiency!
1. Hopper dry, dehumidifier temperature servo system core technology
1) Temperature servo control technology: adopt temperature closed-loop control
2) Servo control technology of fan speed: manual and automatic regulation technology of fan speed
3) Overall safety prevention and control technology: The whole machine adopts triple safety prevention and control technology to ensure the safety of the machine, and all electronic components adopt automobile level accessories
2. Servo system Advantage
1) The process is divided into cold material heating section and heat preservation heating section, and the energy-saving effect is achieved by servo regulation according to the heat exchange required for heat preservation
2) In general, power saving rate: 40% - 70%
3) Power on detection: Thermocouple detection, fan detection, heating rod detection, heating zone thermocouple detection, process parameter detection
4) Detection during operation: temperature rise curve, fan detection, heating rod missing item detection
5) Heating zone temperature protection
6) The temperature adopts servo closed-loop control, and the accuracy is controlled within the thermocouple detection accuracy range, generally plus or minus 1.5 °
3. Specification
Servo model | Driver power | Output voltage | Output current | Dryer model | Heating power | Fan power |
SES100-4T08 | 8kw | 0-380V | 0-21 | 100kg | 7kw | 250w |
SES100-4T12 | 12kw | 0-380V | 0-31 | 150kg | 9kw | 250w |
SES100-4T12 | 12kw | 0-380V | 0-31 | 200kg | 12kw | 400w |
SES100-4T15 | 15kw | 0-380V | 0-39 | 250kg | 14.5kw | 400w |
SES100-4T15 | 15kw | 0-380V | 0-39 | 300kg | 14.5kw | 400w |
SES100-4T18 | 18kw | 0-380V | 0-47 | 400kg | 18kw | 500w |
SES100-4T25 | 25kw | 0-380V | 0-65 | 600kg | 24kw | 800w |
SES100-4T30 | 30kw | 0-380V | 0-79 | 800kg | 30kw | 1100w |
4. Parameter setting, process, operation curve, alarm and other states are clearly visible
5. Installation
The installation of the equipment is very simple, which can be installed by general electricians. In consideration of the universality, the heating and fan are not distinguished from single-phase and three-phase, and the wiring can be done according to the instructions on the equipment
1) Power off of equipment