Rosemount 3051TG1A2C1AB4M5 Smart Pressure Transmitter
Attributes | Brand new |
Parts Category | Transmitter |
Equipment Brand | Rosemount |
SKU | RTT-798 |
Description of Rosemount 3051L/CFP/CFC/CFA/T :
Rosemount 3051CFP Integral Orifice Flow Meters enable highly accurate flow measurement in small line sizes. Internal pipe diameter variation in combination with plate centering issues can greatly magnify flow measurement errors in small line sizes. Integral Orifice Flow Meters use a precision honed pipe section to minimize internal pipe diameter variation along with a selfcentering plate design to eliminate alignment errors.
■ Up to 1.75 percent of flow rate accuracy.
■ Available in ½- to 1½-in. (15 - 40 mm) line sizes.
■ Fully assembled and leak tested for out-of-the-box installation.
■ Simplified flow configuration with clearly displayed flow rate and added totalizer (code M6, BLE, D1, DA1, T9, or RK).
■ Loop Integrity and Plugged Impulse Line Diagnostics detect issues that might compromise the integrity of the output signal (code DA1).
■ Bluetooth enables efficient, reliable, and safe configuration and maintenance (code BLE).
■ Back-lit Graphical Display with Local Language Capability (code M6).
■ Safety certification and proof testing
Rosemount 3051CFC Compact Flow Meters provide a quick, reliable installation between existing raised face flanges. Depending on your application needs, you can reduce energy loss with the Compact Annubar™ or minimize straight run requirements with the Conditioning Orifice.
■ Up to 1.75 percent of flow rate accuracy.
■ Available in ½- to 12-in. (15 to 300 mm) line sizes.
■ Fully assembled and leak tested for out-of-the-box installation.
■ Simplified flow configuration with clearly displayed flow rate and added totalizer (code M6, BLE, D1, DA1, T9, or RK).
■ Loop Integrity and Plugged Impulse Line Diagnostics detect issues that might compromise the integrity of the output signal (code DA1).
■ Bluetooth enables efficient, reliable, and safe configuration and maintenance (code BLE).
■ Back-lit Graphical Display with Local Language Capability (code M6).
■ Safety certification and proof testing
The Rosemount 3051CFA Annubar Flow Meter uses the T-shaped sensor design that delivers best in class accuracy and performance while meeting the needs of diverse process applications, whether it is high accuracy for precision control or high strength for severe flow applications.
■ Up to 1.8 percent of flow rate accuracy.
■ Available in 2- to 96-in. (50 to 2400 mm) line.
■ Fully assembled and leak tested for out-of-the-box installation.
■ Simplified flow configuration with clearly displayed flow rate and added totalizer (code M6, BLE, D1, DA1, T9, or RK).
■ Loop Integrity and Plugged Impulse Line Diagnostics detect issues that might compromise the integrity of the output signal (code DA1).
■ Bluetooth enables efficient, reliable, and safe configuration and maintenance (code BLE).
■ Back-lit Graphical Display with Local Language Capability (code M6).
■ Safety certification and proof testing
Rosemount 3051T In-Line Pressure Transmitters are the industry standard for gage and absolute pressure measurement. The in-line, compact design allows the transmitter to be connected directly to a process for quick, easy and cost effective installation.
■ Loop Integrity and Plugged Impulse Line Diagnostics detect issues that might compromise the integrity of the output signal (code DA1).
■ Bluetooth® Connectivity enables efficient, reliable, and safe configuration and maintenance (code BLE).
■ Back-lit Graphical Display with Local Language Capability
More information:
Description | Part number |
Universal head, SST, display cover, 2-conduit-%-14NPT entries | 00644-4433-0101 |
Connection head, aluminum, standard cover, 2-conduit-M 20×%AN PT entries | 00644-4410-0021 |
Connection head, aluminum, disply cover, 2-conduit-M20x%AN PT entries | 00644-4410-0121 |
Connection head, aluminum, standard cover, 2-conduit-%-14NPT×%AN PT entries | 00644-4410-001 |
Connection head, aluminum, display cover, 2-conduit-%-14NPT×%AN PT entries | 00644-4410-0111 |
Connection head, SST, standard cover, 2-conduit-M 20×%AN PT entries | 00644-4411-0021 |
Connection head, SST, display cover, 2-conduit-M 20×%AN PT entries | 00644-4411-0121 |
Connection head, SST, standard cover, 2-conduit-%-14NPT×%AN PT entries | 00644-4411-0011 |
Connection head, SST, display cover, 2-conduit-%-14NPT×%AN PT entries | 00644-4411-0111 |
Connection head, polished SST, standard cover, 2-conduit-M 20×1.5 entries | 00079-0312-0033 |
Connection head, pol shedS ST, display cover, 2-conduit-M20x 1.5 entries | 00079-0312-0133 |
Connection head, polished SST, standard cover, 2-conduit-M 20×1.5/M 24×1.5 entries | 00079-0312-0034 |
Connection head, polished SST, display cover, 2-conduit-M 20×1.5/M 24×1.5 entries | 00079-0312-0134 |
Connection head, polished SST, standard cover, 2-conduit-%-14NPT entries | 00079-0312-0011 |
Connection head, polished SST, display cover, 2-conduit-%-14NPT entries | 00079-0312-0111 |
Connection head, polished SST, standard cover, 2-conduit-%-14NPSM entries | 00079-0312-0022 |
Connection head, polished SST, display cover, 2-conduit-%-14NPSM entries | 00079-0312-0122 |
Universal head, aluminum, standard cover, 3-conduit-M 20 entries | 00644-4439-0001 |
Universal head, aluminum, display cover, 3-conduit-M 20 entries | 00644-4439-0101 |
Universal head, aluminum, standard cover, 3-conduit-%-14NPT entries | 00644-4439-0002 |
Universal head, aluminum, display cover, 3-conduit-%-14NPT entries | 00644-4439-0102 |
Universal head, SST, standard cover, 3-conduit-M 20 entries | 00644-4439-0003 |
Universal head, SST, display cover, 3-conduit-M 20 entries | 00644-4439-0103 |
Universal head, SST, standard cover, 3-conduit-%-14NPT entries | 00644-4439-0004 |
Universal head, SST, display cover, 3-conduit-%-14NPT entries | 00644-4439-0104 |
In the Features:
Rosemount™ 9295 Process Flow Meter
Rosemount 3051CD/CG/CF
■ Range 0: 750 psi (51.71 bar)
■ Range 1: 2000 psig (137.90 bar)
■ Ranges 2–5: 3626 psig (250.00 bar),
4500 psig (310.26 bar) for option code P9
Rosemount 3051CA
■ Range 1: 750 psia (51.71 bar)
■ Range 2: 1500 psia (103.42 bar)
■ Range 3: 1600 psia (110.32 bar)
■ Range 4: 6000 psia (413.69 bar)
Rosemount 3051TG/TA
■ Range 0: 60 psi (4.14 bar)
■ Range 1: 750 psi (51.71 bar)
■ Range 2: 1500 psi (103.42 bar)
■ Range 3: 1600 psi (110.32 bar)
Description of Rosemount :
HONEYWELL | T921D-1008 T921D 1008 | EMERSON | JP 83023463 3A99266G01 |
HONEYWELL | 51304485-150 MC-PD1X02 | EMERSON | KJ4001X1-BA2 |
HONEYWELL | ACX633 51196655-100 | EMERSON | PR6423/010-010 CON021 |
HONEYWELL | MU-FOED02 51197564-200 | EMERSON | KJ3002X1-BG2 12P1731X032 |
HONEYWELL | MC-PAOY22 80363969-150 | EMERSON | KJ3002X1-BE1 12P0682X052 |
HONEYWELL | 621-9937 | EMERSON | KJ3002X1-BC1 12P0681X092 |
HONEYWELL | 51309218-175 MC-TAMR03 | EMERSON | KJ3002X1-BA1 12P06801X122 |
HONEYWELL | BRC410 SPBRC410 SPBRC41000000 | EMERSON | KJ4001X1-NB1 12P3368X012 |
HONEYWELL | 51196694-928 | EMERSON | KJ4001X1-NA1 12P3373X012 |
HONEYWELL | MU-FOED02 51197564-200 | EMERSON | CE4002S1T2B5 KJ3204X1-BA1 12P3275X022 |
HONEYWELL | FC-PDB-0824P | EMERSON | KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 |
HONEYWELL | CC-PDOB01 51405043-176 | EMERSON | KJ3001X1-BG1 12P0557X162 |
HONEYWELL | 10201/2/1 FC-SDO-0824 | EMERSON | KJ3001X1-BA1 129P549X152 |
HONEYWELL | CC-PDIL01 51405040-175 | EMERSON | KJ3001X1-BA1 12P0549X112 |
HONEYWELL | 621-9940C | EMERSON | KJ3102X1-BA1 12P1863X032 |
HONEYWELL | CC-TAIX01 51308363-175 | EMERSON | VE4003S5B1 KJ3002X1-BG2 12P1731X082 |
Our brand:
1, First, send us the brand, model code/pic of the nameplate, the quantity for inquiry. Then we will send the quote to you. after confirming the model and the quantity, then we will the PI to you.
2, You can transfer by Paypal/ Western Union/Trade assurance/ T/T. When we received the payment, then we will start to prepare the order for you asap.