IC200UDR010 GE Fanuc VersaMax Micro 28 point PLC 24Vdc Out (11) Relay Out 24Vdc
Description for GE Fanuc IC200UDR010
Weight 500 grams (1.10 lbs.)
Inputs Sixteen 24Vdc positive/negative logic input circuits
Outputs Eleven normally-open 2 amp relay circuits and One DC Output (Q1)
High-Speed Counters Up to four Type A or one Type A and one Type B
+24Vdc Output Power Supply 200mA maximum (for input circuits and user devices)
Thermal Derating IC200UDR010: none. IC200UDR228: no derating to 45 degrees C. Above 45
degrees C, number of points on at the same time must not exceed 50%.
DC Power Specifications
Range IC200UDR010: 24Vdc -20%, +25%
IC200UDR228: 9.2 to 30Vdc
Hold-up IC200UDR010: 10ms at 19.2Vdc
IC200UDR028: 5ms
Inrush Current IC200UDR010: 1 Amp maximum at 30Vdc
IC200UDR228: 13 Amps at 12Vdc, 27 Amps at 24Vdc
Inrush Time 10mS for 1 A
Input Current IC200UDR010: 0.30 Amp typical at 24Vdc
IC200URD228: 1.1 Amp typical at 12Vdc; 0.55 Amp typical at 24Vdc
Input Power Supply Rating 8W
DC Input Specifications
Number of Inputs 16
Rated Input Voltage 24 volts DC
Input Voltage Range 0 to 30 volts DC
Input Current 7.5mA typical
Input Resistance 2.8 kΩ
Input Threshold Voltage ON: 15Vdc minimum, OFF: 5Vdc maximum
Input Threshold Current ON: 4.5mA maximum, OFF: 1.5mA minimum
Response Time 0.5 to 20ms configurable as regular input; 100µs as HSC input
Isolation Voltage 1500V RMS field side to logic side, 500V RMS between groups
DC Output Specifications
Output logic Positive Logic
Operating Voltage IC200UDR010: 24Vdc / 12Vdc / 5Vdc; IC200UDR228: 24Vdc / 12Vdc
Voltage Range IC200UDR010: 24Vdc, +20%, -80%; IC200UDR228: 23.5 - 24.5Vdc
Output Current IC200UDR010: 450mA; IC200UDR228: 100mA
Maximum UL Pilot Duty Rating 0.75A at 24Vdc
Maximum Resistive Load Rating 0.75A at 24Vdc; 0.5A at 12Vdc; 0.25A at 5Vdc
Output Voltage Drop 0.3Vdc maximum
Response ON: 0.1ms maximum (24Vdc, 0.2A), OFF: 0.1ms maximum (24Vdc, 0.2A)
OFF state leakage 0.1mA maximum
Isolation 1500Vac between field side and logic side, 500Vac between groups
Fuse Output should be fused externally. Otherwise, a load short can
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
Honeywell TC-,TK- | GE Modules IC - |
ABB Module | AB Module 1756-,1759- Tourch Screen 2711- |
Mitsubishi Drive MR- , Motor HA -,HC | Emerson MoudlesVE- ,KJ - |
Fanuc motor A0-, Drive | Yokogawa transmitter EJA- |
Rosemount Transmitter 3051- | Schneider Module 140- |
Panasonic Motor , Drive MH- | Siemens Module 6ES-, Touch Screen 6AV- |
6.11 IC200UDR010 28-Point Micro PLC, (16) 24Vdc In, (1) 24Vdc Out, (11) Relay Out, 24Vdc PS
IC200UDR228 28-Point Micro PLC, (16) 24 VC In, (1) 24Vdc Out, (11) Relay Out,
12/24Vdc PS
VersaMax Micro PLCs IC200UDR010 and IC200UDR228 accept sixteen DC inputs and provide one DC
output and eleven normally-open 2 Amp relay outputs. The only differences between these modules
are their power supplies and the output current rating of their Q1 DC output. Micro-28 IC200UDR010
uses +24Vdc nominal input power, and provides a 450mA, 24Vdc output. Micro-28 IC200UDR228
uses +12/24Vdc nominal input power, and provides a 100mA, 24Vdc output.
6.11.1 DC Power
The DC power supply requires more current at startup voltage (approximately 4Vdc) than at rated
input voltage. A minimum of 2.0 A is required to start up the DC power supply.
If configured to disable power-up diagnostics, the PLC begins logic solution 100ms after the voltage
level of the power supply input reaches and maintains nominal DC power. The power source for the
PLC must have enough transient current capability to support the inrush current of the power supply
and to maintain an adequateVdc voltage level (see specifications for inrush requirements).
6.11.2 DC Inputs
The sixteen configurable DC inputs can be used as positive or negative logic standard inputs or up to
three High-Speed Counter inputs. Inputs are compatible with a wide range of input devices, such as
pushbuttons, limit switches, and electronic proximity switches.
The Micro PLC’s +24Vdc supply can be used for input devices and to power the DC input circuits at
about 7.5 mA per input. The combination of input circuit current and external device current must not
exceed 200 mA.
6.11.3 DC Output (Q1)
The DC output circuit (Q1) can be configured to be a standard, High-Speed Counter, pulse train, or
PWM output.
6.11.4 Relay Outputs (Q2 – Q12)
Eleven Form A relay outputs (SPST-single pole single throw) can control a wide range of load devices
such as motor starters, solenoids, and indicators. The switching capacity of each of these circuits is 2
amps. An external source of AC or DC power must be supplied to operate field devices. Relay outputs
cannot be used as Pulse Train or PWM outputs.
Similar prodcut for GE Fanuc IC200UDR010
Part Number | Description |
All Parts Commonly | Call Parts Super Center 800-727-8443 |
106B7033P1 | Operating Arm, IC9445 Lever Limit Switch |
106B7085G5 | Cam Follower, IC9446 Rotating Limit Switch |
117A7920P1 | Roller, IC9445 Lever Limit Switch |
129B5749P1 | Star Wheel, IC9445 Lever Limit Switch |
144A4871P2 | Shaft, IC9445 Lever Limit Switch |
1970369P7 | Weight for Operating Arm, IC9445 Lever Limit Switch |
721B773G1 | Contact Unit, IC9445 Lever Limit Switch |
721B773G3 | Contact Unit, IC9445 Lever Limit Switch |
Limit Switch, Lever, General-purpose, Standard Contact, 1 Circuit, IC9445 Lever Limit Switch | |
IC9445A200AB | Limit Switch, Lever, General-purpose, Standard Contact, 2 Circuits, IC9445 Lever Limit Switch |
IC9445A200AC | Limit Switch, Lever, General-purpose, Maintained Contact, 2 Circuits, IC9445 Lever Limit Switch |
IC9445A204AM | Limit Switch, Lever, General-purpose, Snap Action Contact, 2 Circuits, IC9445 Lever Limit Switch |
IC9445B200AA | Limit Switch, Lever, Watertight, Standard Contact, 1 Circuit, IC9445 Lever Switch |
Limit Switch, Lever, Watertight, Standard Contact, 2 Circuits, IC9445 Lever Limit Switch | |
IC9445B200AC | Limit Switch, Lever, Watertight, Maintained Contact, 2 Circuits, IC9445 Lever Limit Switch |
IC9445B206AM | Limit Switch, Lever, Watertight, Snap Action Contact, 2 Circuits, IC9445 Lever Limit Switch |
IC9445B206AN | Limit Switch, Lever, Watertight, Snap Action Contact, 1 Circuit, IC9445 Lever Limit Switch |
IC9445C200 | Limit Switch, Lever, Weight, Cable, General-purpose, IC9445 Lever Limit Switch |
IC9445C208 | Limit Switch, Lever, Less Weight, Cable, General-purpose, IC9445 Lever Limit Switch |
IC9445D200 | Limit Switch, Lever, Weight, Cable, Watertight, IC9445 Lever Limit Switch |
IC9445D204 | Limit Switch, Lever, Less Weight, Cable, Watertight, IC9445 Lever Limit Switch |
IC9445H200AA | Limit Switch, Lever, Watertight Bronze, Standard Contact, 1 Circuit, IC9445 Lever Limit Switch |
IC9445H200AB | Limit Switch, Lever, Watertight Bronze, Standard Contact, 2 Circuits, IC9445 Lever Limit Switch |
IC9445Y100 | Lever, Straight, Molded Phenolic, 4 Inch, IC9445 Lever Limit Switch |
IC9445Y101 | Lever, Straight, Hardened Steel, 4 Inch, IC9445 Lever Limit Switch |
IC9445Y102 | Lever, Forked Roller, Harden Steel, IC9445 Lever Limit Switch |
IC9445Y103 | Lever, Straight, Hardened Steel, 4 Inch, IC9445 Lever Limit Switch |
IC9445Y106 | Lever, Crane Hoist Hook, 6 Feet Cable, IC9445 Lever Limit Switch |
IC9445Y108 | Lever Straight, IC9445 Lever Limit Switch |
IC9445Y110 | Lever, Fork, IC9445 Lever Limit Switch |
IC9445Y111 | Lever, Straight, Molded Phenolic, 7 Inch, IC9445 Lever Limit Switch |
IC9445Y112 | Lever, Straight, Molded Phenolic, 6 Inch, IC9445 Lever Limit Switch |
IC9445Y113 | Lever, Offset, Molded Phenolic, 6 Inch, IC9445 Lever Limit Switch |
IC9445Y114 | Lever, Straight, Hardened Steel, 6 Inch, IC9445 Lever Limit Switch |
IC9445Y115 | Lever, Straight, Hardened Steel, 6 Inch, IC9445 Lever Limit Switch |
IC9445Y116 | Lever, Straight, Composition Rubber, 6 Inch, IC9445 Lever Limit Switch |
IC9445Y138 | Lever, Hardened Steel, 7 Inch, IC9445 Lever Limit Switch |