♦ Components through TLC-Certified,Conform to YD1117-2001
Fiber PLC Splitter Applications:
♦ Fiber to The Point (FTTX)
♦ Fiber to The Home (FTTH)
♦ Passive optical networks(PON)
♦ Local Area Networks (LAN)
♦ Cable Television (CATV)
♦ Test Equipment
1x8 PLC Splitter with SC/PC Specification
Parameters | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 | 1×128 | |
Operating Wavelength (nm) | 1260~1650 | |||||||
Fiber Type | G657A1 or customer specified | |||||||
Insertion Loss (dB)(P/S Grade) | 3.8/4.0 | 7.2/7.4 | 10.3/10.7 | 13.5/13.7 | 16.5/16.9 | 20.5/21.0 | 23.8/24.2 | |
Loss Uniformity (dB) | 0.4 | 0.6 | 0.8 | 1.0 | 1.5 | 2.0 | 2.5 | |
Polarization Dependent Loss(dB) | 0.1 | 0.1 | 0.1 | 0.20 | 0.25 | 0.30 | 0.4 | |
Return Loss (dB)(P/S Grade) | 55/50 | 55/50 | 55/50 | 55/50 | 55/50 | 55/50 | 55/50 | |
Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 | 55 | |
Wavelength Dependent Loss (dB) | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 | 0.5 | 0.5 | |
Temperature Stability (-40~85 ℃)(dB) | 0.4 | 0.4 | 0.4 | 0.5 | 0.5 | 0.5 | 0.5 | |
Operating Temperature (℃) | -40~80 | |||||||
Storage Temperature (℃) | -40~85 | |||||||
Device Dimension (mm) | 40×4×4 | 40×4×4 | 40×4×4 | 50×7×4 | 50×7×4 | 60×12×4 | N/A | |
Module Dimension (mm) | 100×80×10 | 120×80×18 | 141×115×18 | |||||
Mini-Module Dimension (mm) | 60×4×4 | 60×7×4 | 60×7×4 | 60×12×4 | 80×20×6 | 100×40×6 | N/A |
1x8 PLC Splitter with SC/PC connector Dimensions
Name of the test | Condition | Duration |
Temperature- Humidity aging | 85°C and 85% RH | 7 days |
Vibration | 10 - 55Hz, 1.52mm double amplitude, in three axes | 1 hour |
Component Impact | Test Impact of 500g (mass ≤ 0.125kg), 1ms , half sine pulse | 2 impacts |
Temperature Cycling Test | -40 - 70°C, Ramp rate: 1°C /min, Dwell time > 15min | 10 cycles |
Temperature- Humidity cycling | -40 - 85°C , between 10°C and 23°C - 85% RH, at 85°C - 20%RH, between °C and 85°C - maintain a linear change in RH, below 10°C - uncontrolled RH | 14 days |
Water Immersion | 43 ± 2°C , PH 5.5 ± 0.5 | 7 days |
Fiber Side Pull test | 0.23 kg load, 90° angle , 2 directions | 5 seconds |
Fiber Side Pull test | 0.45 Kg load for Single Input Fiber, 1.5 Kg load for 8 Fiber Ribbon Outputs | 5 seconds |
PLC | Port Configutation | Package Style | Fiber Diameter (Input/ Output) | Connector (Input/Output) | Pigtail Length |
PLC=PLC Splitter | 102=1×2 | ST=Steel tube, bare fiber | 25=250μm | NO=None | 15=1.5m |
| 104=1×4 | MM=Mini module | 90=900μm | SCA=SC/APC | 20=2.0m |
| 108=1×8 | FO=With fan-out | 20=2.0mm | SCU=SC/UPC | 30=3.0m |
| 116=1×16 | ABS=Pigtailed ABS box | 30=3.0mm | LCA=LC/APC | XX=Customized |
| 132=1×32 | MP=Mini plug-in type | | LCU=LC/UPC | |
| 164=1×64 | LGX=Standard LGX | | FCA=FC/APC | |
| 202=2×2 | TR=Mounted on a Fiber Splice Tray | | FCU=FC/UPC | |
| 204=2×4 | 1U=1U 19” rack mount chassis | | STA=ST/APC | |
| 208=2×8 | | | STU=ST/UPC | |
| 216=2×16 | | | X=Customized | |
| 232=2×32 | | | | |
| 264=2×64 | | | | |