Working Principle :
CO2 fractional laser effect principle is "focal photothermal effect ". Skin tissue has ability to repair itself. The skin was
injury by trauma, but it could heal itself. The wound area is too large, the results of repair of scar formation. The wound is
small, the skin can completely recover. Fractional laser every effect to skin only on one of the small region to generate thermal stimulation, retaining portion of skin is not affected, the role of tissue to the skin to stimulate collagen receipt hyperplasia, and no effect of skin tissue can be used as thermal diffusion region, avoid the possibility of thermal injury and other side effects, and can quickly promote skin healing, reach, and improve scars, skin firming pores purpose.
Professional clinic use Fractional CO2 Laser with 3 systems
1. Fractional and cutting 2 systems standard; Gynecology system optional
2. Umanized software control, more effective in treatment results
3. 14 variable treatment graphics, adjustable shapes, sizes and spacing
4. 7 Joints articulated light guiding arm; Convenient and flexible in operation, greatly reducing energy loss
5. USA imported RF laser tube; steady and even laser output
6. 1-3 times Fast and effective solve scar and vagical problem.
7. 360 degree scanning ability of fractional handle .
8. Minimal side effects and no down time.
9. Wide application for treatment of dermatology, gynecology, general surgery, ENT and anorectal etc.
| |
Laser type | USA Coherent laser (RF Tube, lifetime 5-10 years) |
Wavelength | 10600nm |
Systems | Fractional and cutting system standard; Vaginal system optional |
Output Power | 1-40W |
Input Power | 600W |
Output Graphics | Standard Triangles, Rectangles, Circles, Hexagons. Totally 14 graphics available. |
Light guiding system | 7 joints,360° rotation |
Spot size | 0.08-0.12mm |
Scan area | Up to 20*20mm |
Aiming beam | 650nm red diode laser, laser power 0.1-5mW |
Cooling system | Cooling system |

Vaginal Tightening Working Theory
Vaginal tightening laser is the use of water uptake 10600nm gold standard laser, using a three-dimensional lattice technology and 360-degree circular emission perfect combination of technology, to produce 50-70 degrees Celsius in a controlled depth of the vaginal mucosa, stimulate lamina propria and myometrium newborn fibroblasts, and damaged collagen fibers, elastic fibers, such as restructuring, so as to achieve vaginal wall thickening and tighteningof the vagina so that firmness, sensitivity enhancement, vagina tight as ever.