Stability Walk in environmental test chamber, climatic test chamber
The stability walk in climatic test chamber are qualifiable and are designed specifically according to customer need. There various size for your choices it, the largest volume can reached at 47M3, and the largest size about 5,400mm.
The walk in test chamber is well suited for testing the storage transport and usage of eletronic product, auto componet and raw materials under high temperature and low temprature environments.
Technical Parameters of Stability Walk in environmental test chamber
Model | WTH40 | WTH60 | WTH80 | WTH120 | WTH160 | WTH180 | WTH230 | WTH290 | WTH310 | WTH390 | WTH470 | |
Volume (m³) | 3.9/3.4 | 6.3/5.5 | 7.8/6.8 | 11.7/10.2 | 15.6/13.6 | 17.5/15.3 | 23.3/20.4 | 29.2/25.5 | 31.1/27.2 | 38.9/34.0 | 46.7/40.8 | |
Temperature range | -60°C -100°C (-70°C -120°C /-70°C -150°C optional) | |||||||||||
Humidity range | 20%RH~98%RH/(20~85°C) | |||||||||||
Temperature fluctuation | ±0.5°C | |||||||||||
Temperature deviation | ±2°C | |||||||||||
Humidity deviation | ±3.0%RH(≧75%);±5.0%RH(≦75%) | |||||||||||
Warm-up time | 25°C~+100°C(120°C,150°C optional) | |||||||||||
≦25MIN | ≦28MIN | ≦28MIN | ≦30MIN | ≦31MIN | ≦32MIN | ≦34MIN | ≦36MIN | ≦38MIN | ≦41MIN | ≦45MIN | ||
Cooling time | + 25℃ ratedlimit low temperature 30min-180min (it is different according to different models and configurations ) | |||||||||||
Inner size(mm) | W | 1800 | 2700 | 3600 | ||||||||
H | I type:2100 II type:2400 | |||||||||||
D | 900 | 1450 | 1800 | 1800 | 1800 | 2700 | 3600 | 4500 | 3600 | 4500 | 5400 | |
Temperature & humidity regulating method | BT(H) C balance temperature regulation (humidity regulation) manner | |||||||||||
Working environment temperature | +5°C~+35°C | |||||||||||
Protection building envelope | Spraying plastics galvanizing color steel plate, temperature resistant stress thermalinsulation material, SUS304stainless steel composite assembly plate |
Notes:
1. Height: I type:2100mm, II type 2400mm
2. Above parameters are measured when the ambinet temperature is +25℃ and circulating water temperature is +25℃.
3. The fluctuation parameter is tested in accordance with GB/T5170.2-2008 stardard.
4. The above-mentioned products are designed with a humidifier.
Cases
Through more than 20 years of hard work, we have established friendly relationship with customers both at home and abroad. Some of them are well-know companies and organizations, like SGS, SONY, TUV AND FORD, etc.
For futher information pls contact with us:
Item | Detail Information |
Phone&Wechat ID&whatsapp | 0086 186 7605 0580 |
Simplewell02@163.com;simplewell02@hotmail.com; | |
Skype | 0086 186 7605 0580 |
1181717893 |