KST thermal shock test chamber (Basket Type) wtihout moving test samples
Test area capacity: 40L to 300 L
Product purpose
The equipment is suitable for each kind of electronic product and other product; and the parts and materials are subjected to high/ low temperature constant and each kind of temperature impact and temperature quick change reliability test.
Reference Standards
*GB/T2423.1-2008 Test A: Low Temperature Test Method
*GB/T2423.2-2008 Test B: High Temperature Test Method
*GB/T2423.22-2002 Test N: Low Temperature Test Method
*GJB150.3-1986 High Temperature Test
*GJB150.4-1986 Low Temperature Test
*GJB150.5-1986 Temperature Shock Test
Technical Parameters of 3-Zones Thermal shock test chamber
Model | KTS-41A | KTS-41B | KTS-41D | KTS-71A | KTS-71B | KTS-71C | KTS-110A | KTS-110B | KTS-110D | KTS-301A | KTS-301B | KTS-3011D | ||||||
Temperature range of test chamber | +60~+200°C | +60~+200°C | +60~+200°C | +60~+200°C | ||||||||||||||
-40~+0°C | -55~+0°C | -65~+0°C | -40~+0°C | -55~+0°C | -65~+0°C | -40~+0°C | -55~+0°C | -65~+0°C | -40~+0°C | -55~+0°C | -65~+0°C | |||||||
Cooling mode | Wind cooling or water cooling optional | |||||||||||||||||
Temperature recovery condition | High temperature exposure | + 150℃ 30min | ||||||||||||||||
Normal temperature exposure | 5 min | |||||||||||||||||
Low temperature exposure | -40℃ 30min | -55℃ 30min | -65℃ 30min | -40℃ 30min | -55℃ 30min | -65℃ 30min | -40℃ 30min | -55℃ 30min | -65℃ 30min | -40℃ 30min | -55℃ 30min | -65℃ 30min | ||||||
Temperature recovery time | 5 min | |||||||||||||||||
Inner size(mm) | W | 240 | 410 | 650 | 970 | |||||||||||||
H | 460 | 460 | 460 | 460 | ||||||||||||||
D | 370 | 370 | 370 | 670 | ||||||||||||||
External size (mm) | W | 1300 | 1300 | 1500 | 1500 | 1720 | 1720 | 2050 | 2050 | |||||||||
H | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | ||||||||||
D | 1700 | 1800 | 1700 | 1800 | 1800 | 1900 | 2100 | 2200 | ||||||||||
Sample | 2.5KG | 5KG | 10KG | 24KG | ||||||||||||||
Power | Ac380±10% three phase and four wire protection ground wire) / AC220V /AC110 50Hz / 60HZ | |||||||||||||||||
Compressed air | 0.4~0.7MPa | |||||||||||||||||
Water pressure | 0.2~0.5MPa |