IEC 60529 Integrated IPX1~6 Waterproof Test System For Testing Electrical Product
Product Overview For Integrated IPX1~6 Waterproof Test System:
The equipment is designed and manufactured according to requirements of IEC 60529 for IPX1 to IPX6 tests. It is used for testing electronic and electrical products, lamps, electric cabinets, electrical components, automobiles, motorcycles and their parts and components’ physical and other related properties under simulated climatic conditions. After the test, it is judged whether the performance of the product meets the requirements, so as to facilitate the design, improvement, verification and factory inspection of the product.
Technical Parameters For Integrated IPX1~6 Waterproof Test System:
The total size of the laboratory: 6.5×3.6×4.2m (width*depth*height) (room and drainage tank are prepared by the user) | |
IP12 | |
Drip area size | 2000×2000*60mm (W*D*H) |
Maximum sample size | 1800*1800*500mm |
Distance between drip tank and sample | 200 mm (inside) |
Drip hole diameter | φ0.4mm |
Spray aperture spacing | 20 mm |
Rainfall | 1+0.5mm/Min 3+0.5mm/Min |
Turntable | IPX1 turntable is parallel, IPX2 turntable can be tilted 15° |
Air source | The buyer should prepare a air source of more than 5kg |
Rack material | Coated aluminum alloy profile |
IP34 | |
Oscillating tube radius | 200, 400, 600, 800, 1000, 1200, 1400, 1600 (mm) |
Distance from nozzle to sample | 200mm (inside) |
Spray aperture spacing | 50mm |
Spray pipe oscillating angle range | 120° 320° (can be set) |
Nozzle angle | 120°(IP3) 180°(IP4) |
Oscillation speed | 30°/s oscillating speed: IP3 15 times/min; IP4 5 times/min |
Spray hole diameter | φ0.4 (mm) |
Flow per spray hole | 0.07 L/min +5% |
Spray pressure | 80-150 (Kpa) |
Sprinkler System | IP34: Determine the number of nozzles according to the number of oscillating pipes |
Water flow | IP34 The water flow rate is determined by the number of oscillatinging nozzles |
IP56 | |
Number of nozzles | 2 pcs; 1 IPX5 nozzle and 1 IPX6 nozzle |
Tested surface | The side of the product is the tested surface |
Nozzle distance from sample | 2500~3000mm, the distance is controlled by the tester |
Nozzle inner diameter | IPX5 (grade) φ6.3 mm, IPX6 (grade) φ12.5 mm |
Spray flow | IPX5 (grade) 12.5±0.625(L/min), IPX6(grade) 100±5(L/min) |
Pipe diameter | One four-point and one-inch high-pressure hose |
Spray pressure | 30~200kpa (according to flow adjustment) |
Spray duration | 3, 10, 30, 9999min (adjustable) |
Runtime control | 1~9999min(adjustable) |
Water spray pressure gauge | Water spray pressure can be displayed |
Control system | Self-developed touch screen control system |
Spray system | Consists of water pump, water pressure gauge, fixed nozzle bracket |
Nozzle material | SUS304 stainless steel pipe |
Water tank material | SUS304 stainless steel (professional brushed) |
Frame material | Coated aluminum alloy profile |
Control cabinet material | SUS304 stainless steel (professional brushed) |
Shared system
| Turntable speed: 1 ~ 7r/min adjustable |
Turntable load: 150 kg | |
Turntable height adjustable: 300-600mm | |
Turntable diameter: 200mm, 400mm, 1000mm | |
Shared water tank | Water tank size: 800×800×1000mm (W*D*H) |
Water level: transparent hose, equipped with stainless steel ruler to observe the water level, the height of the ruler is 1.0m, and the accuracy of the ruler is 1mm. | |
Water tank control: stainless steel float, overflow hole | |
The box body is reinforced with 304 stainless steel square tube | |
Mobility: four universal casters to move freely, with brakes | |
Bottom setting: the water tank is pumped and pressurized by the stainless-steel water pump inside the right control box, and then sent to the nozzle of the side spray pipe device. Nozzles spray water laterally onto the samples above the turntable. Then it is scattered into the water tank to form a water circulation system. Control components such as flowmeters, pressure gauges, and solenoid valves are designed at the pump outlet. The inner box is equipped with a waterproof turntable, and the speed is controlled on the panel. |