IEC 60884-1:2022 Gauges For Checking Dimensions For VDE Type Plugs Sockets
Product Information For VDE Gauges:
These measuring gauges confirm to the standard of IEC 60884-1:2022 clause 9, which are used for the dimensional measurement and verification of the plug socket for household and similar use. They are the necessary testing devices used in the laboratory and measurement test department. The specific measuring gauges are made according to DIN VDE 0620-1:2010:
Technical Parameters For VDE Gauges:
No.: | Figure No. | Name | QTY |
Standards:IEC60884-1:2013 & DIN VDE 0620-1:2010 Gauge List & Quote | |||
1 | DIN-VDE0620-1-Lehre1 | Socket jack R size gauge (5.0, 5.8, 6.0) | 3 PCS |
2 | DIN-VDE0620-1-Lehre2 | Minimum opening width and minimum withdrawal force of contact socket | 2 PCS |
3 | DIN-VDE0620-1-Lehre3 | Insertion force of bipolar plug | 1 PC |
4 | DIN-VDE0620-1-Lehre4 | Insertion force of double board plug with side grounding contact | 1 PC |
5 | DIN-VDE0620-1-Lehre5 | A gauge used to test the interval of the first contact closure | 1 SET/ 4 PCS |
6 | DIN-VDE0620-1-Lehre6 | Diameter of the pin | 1 SET/ 4 PCS |
7 | DIN-VDE0620-1-Lehre7 | Pin distance | 1 SET/ 2 PCS |
8 | DIN-VDE0620-1-Lehre8 | Maximum opening width of contact socket | 1 PC |
9 | DIN-VDE0620-1-Lehre9 | Test plug interchangeability gauge | 1 PC |
10 | DIN-VDE0620-1-Lehre10 | Impossible A of Single pole contact hole contact | 1 PC |
11 | DIN-VDE0620-1-Lehre10 | Impossible B of Single pole contact hole contact | 1 PC |
12 | DIN-VDE0620-1-Lehre11 | Non-pluggability of bipolar plugs without grounding contacts | 1 PC |
13 | DIN-VDE0620-1-Lehre12 | Impossibility of single-pole plug insertion (including 250g and 1000g weights) | 1 SET |
14 | DIN-VDE0620-1-Lehre13 | Probe to check the inaccessibility of live parts in the protection door after the normal operation test | 1 SET |
15 | DIN-VDE0620-1-Lehre14 | Test for grounding on both sides | 1 PC |
16 | DIN-VDE0620-1-Lehre15 | Probes used to check the inaccessibility of live parts in the protection door and the live parts of the enhanced protection socket | 1 SET |
17 | DIN-VDE0620-1-Lehre16a | Maximum withdrawal force of plug (16a) | 1 PC |
18 | DIN-VDE0620-1-Lehre16b | Maximum withdrawal force of plug (16b) | 1 PC |
19 | DIN-VDE0620-1-Lehre16c | Maximum withdrawal force of plug (16c) | 1 PC |
20 | DIN-VDE0620-1-Lehre16d | Maximum withdrawal force of plug(16d) | 1 PC |
21 | DIN-VDE0620-1-Leher16e | Gauge (including 18N weight) | 1 PC |
22 | DIN-VDE0620-1-Lehre17 | Lehre17 gauge | 1 PC |
23 | DIN-VDE0620-1-Lehre18 | Lehre18 gauge | 1 PC |
24 | DIN-VDE0620-1-Leher19a | Force measuring gauge for 16A socket protection door | 1 PC |
25 | DIN-VDE0620-1-Leher19b | Force measurement gauge for 2.5A socket protection door | 1 PC |
26 | DIN-VDE0620-1-Bild14 | Bild14 gauge | 1 SET |
27 | DIN-VDE0620-1-Bild43 | Bild43 gauge | 1 SET / 2 PCS |
28 | DIN-VDE0620-1, EN50075-Fig2 | Gauge for testing plug interchangeability | 1 PC |
29 | DIN-VDE0620- 1-Bild16a | 16A temperature rise plug gauge 2P+E | 1 PC |
30 | DIN-VDE0620- 1-Bild16b | 16A temperature rise plug gauge 2P+N+E | 1 PC |
31 | DIN-VDE0620- 1-Bild16a | 25A temperature rise plug gauge 3P+N+E | 1 PC |
32 | DIN-VDE0620- 1-Bild16d | 2.5A temperature rise plug gauge 2P+E | 1 PC |
1. Please do not damage the appliance shape (such as scratching, bending, etc.).
2. Prevented from dust and moisture environment, in order to avoid the oxidation to affect the dimensional accuracy.
3. Add anti-rust oil regularly.