IEC 60884-2022 VDE Type Plug And Socket Conductor Damage Test Equipment
Product Information For Conductor Damage Degree Test Equipment:
Standards: IEC 60884-1: 2022 Section 12.2.5 (Figure 11), IEC 60669-1: 2017 Sections 12.2.5 and 12.3.10 (Figure 9), UL486A-B, etc.
Application: This device is used to check whether terminals with screws and without screws can withstand mechanical forces under normal operation. It is mainly used to determine whether the design and structure of the screw clamping terminal meet the requirements of clamping the wire without excessive damage.
Test Samples: Terminals, Connectors
Features Guide rail structure is adopted. The test time can be preset. When the test is over, the tester will stop automatically and output sound alarm signal.
Technical Parameters For Conductor Damage Degree Test Equipment:
Applied standard | IEC 60884-1: 2022 |
Applied clause | 12.2.5, figure 11 |
Test sample | Terminals, connectors |
Test rate | 10±2 RPM |
Diameter of gyration | 75mm (and 76mm for UL standard) |
Test times | 0~9999 |
Weights | 0.3, 0.4, 0.7, 0.9, 1.4, 2kg |
Test height | 260, 280, 300, 320mm |
Diameter of ferrule hole | 6.5, 9.5, 13, 14.5mm |
Power supply | AC220V±10%, 50Hz |