Automotive Sun Simulation System Halogen Lamp Room Walk In Evironmental Chamber
System overview:
The system is composed of intelligent control power supply, optimized design of reflector lamp housing, Osram 2500W metal halogen lamps, cabinet, illuminance meter, etc. It can perfectly simulate the sunlight irradiation environment under various conditions. Coupled with environmental factors such as temperature, humidity, rain, and snow, it is used to evaluate the impact of direct solar radiation on the test specimen (thermal, mechanical, chemical, electrical, etc.), and can also be used to reveal the mutual interaction between different materials in the component effect. The sunlight simulation system can be used alone for testing of electronics, materials, and small-volume test pieces. Multiple sets of systems can also be combined into a light array through professional design and layout, which is used for the test of cars, trucks, photovoltaic modules, even trains and airplanes.
Sunlight simulation system:
This test system consists of a total of 98 sunlight simulation units (14 × 7) or can be customized. Each sunlight simulation unit has the same power and is 4KW. The specific distribution is as follows:
Spectral region | Bandwidth (nm) | Radiation (% of total) | Tolerance Min | Tolerance Max | Irradiance (W/m²) | Spectral region Irradiance (W/m²) |
UVB | 280 to 320 | 0.5 | 0.3 | 0.7 | 5.6 | 5.6 |
UVA | 320 to 360 | 2.4 | 1.8 | 3 | 26.9 | 62.7 |
360 to 400 | 3.2 | 2.4 | 4.4 | 35.8 | ||
VIS | 400 to 520 | 17.9 | 16.1 | 19.7 | 200.5 | 580.2 |
520 to 640 | 16.6 | 14.9 | 18.3 | 185.9 | ||
640 to 800 | 17.3 | 12.8 | 19 | 193.8 | ||
IR | 800 to 3000 | 42.1 | 33.7 | 50.5 | 471.5 | 471.5 |
Total | 1120 | 1120 |
Working Dimensions: D×W×H | 2500×2500×2500MM, can be customized | ||
External Dimensions: D×W×H | 4100X3100X3000MM, can be customized | ||
Power (kw) | 13KW or depended on final design | ||
Performance | Temperature Range | Working room temperature: -30 ℃ ~ 85 ℃ (dark cycle) | |
Humidity Range | 1. Lighting cycle: 10 ~ 60% RH 2. Humidity range of dark cycle: up to 100% 3. Humidity accuracy: ≤ ± 5% | ||
Spectral Wavelength | 290-2450nm optional | ||
Lamp Radiation Intensity | 1050W/m2 accuracy≦±0.01W/m2 | ||
Lamp Tube Power | 2.5KW (Air-cooled full solar spectrum metal halogen lamps) | ||
Lamp Total Power | 10KW, lifespan:1000 hours | ||
Blackboard Temperature | BST control range: 80 ℃ (adjustable) BPT control range: 80 ℃ (adjustable) | ||
Distance from Arc Center to Sample | 1200mm, effective exposure area ≥ 3000cm2 | ||
Sample Rack | 1200X1200MM, can be customized | ||
Accuracy Range | Setting / indication accuracy: temperature 0.1 ℃, humidity 1% RH | ||
Temperature and Humidity Sensor | Platinum resistance.PT100Ω / MV | ||
Heating System | Fully independent system, nickel-chromium alloy electric heater | ||
Humidification System | External isolation type, all stainless steel shallow surface evaporative humidifier | ||
Blackboard Temperature | Bimetallic blackboard thermometer | ||
Temperature Controller | Adopt Siemens color touch screen and German Siemens PLC module control | ||
Circulatory System | Temperature-resistant and low-noise air-conditioning motor. Multi-blade centrifugal wind wheel | ||
Material | Outer Chamber Material | High quality carbon steel plate, phosphating electrostatic spray treatment / SUS304 stainless steel matte line hairline treatment | |
Inner Chamber Material | SUS304 high-quality stainless-steel smooth plate | ||
Sample Rack Material | SUS304 high-quality stainless-steel bar | ||
Door Frame Insulation | High and low temperature aging silicone rubber door sealing strip | ||
Number of Sample Racks | The number of samples is 16, according to the blackboard temperature and irradiation sensor | ||
Sun Eye | Intelligent irradiation induction loop system with German chip. Automatically correct the setting value of irradiation intensity. It is high temperature and high humidity resistance; shell is made of 304 material. | ||
Standard Configuration | 1 set of anti-radiation glass windows, 4 lamps | ||
Safety Protection | Protection of electric leakage, short circuit, over temperature, water shortage, motor overheat, over current | ||
Power Supply | AC380V±10% 50±0.5Hz three-phase five-wire system | ||
Use Ambient Temperature | 5℃~+30℃ ≤85%RH |