Specifications
Brand Name :
Sinuo
Model Number :
SNBT4008FA-20V30A
Certification :
Calibration Certificate (Cost Additional)
Place of Origin :
China
MOQ :
1
Price :
Customized
Payment Terms :
T/T, L/C, Western Union, MoneyGram
Supply Ability :
10 Sets Per Month
Delivery Time :
1 Month
Packaging Details :
Plywood
Voltage Range :
100mV~20V
Min. Discharge Voltage :
2.5V
Cutoff Current :
0.06A
Current Range :
150mA~30A
Accuracy :
± 0.1% of FS
Channels Per Unit :
8
Description

IEC62133-1 20V 30A Charge Discharge Capacity Lithium Ion Battery And Cell Test Equipment

Overview:

This battery charge discharge testing equipment meets the requirements of battery and cell pulse charge and discharge test, DC internal resistance (DCIR) test, cycle life (Cycle Life) test, rate charge and discharge test. This testing equipment comes with unique software, which can run on computer to achieve romote control and minitor.
This series of battery testing systems are widely used in various research institutions, universities and power battery manufacturers.

Standards & Clauses:

Conforms to IEC62133-1/-2:2017 clause 7.1, 7.2.1, 7.3.8, 7.3.9, IEC62133-1/-2:2012 clause8.1.1, 8.1.2, 8.2.1, 8.3.6, 8.3.7 IEC60086-4 clause 6.5.8 6.5.9 IEC60622, IEC60623, IEC 60086-1, IEC61951, IEC61960

Technical Parameters:

Project index

Parameter index

Input PowerAC 220V ±10% / 60Hz (can be customized)
resolutionAD:16bit;DA:16bit
Input Resistance≥1MΩ
Input Power6684W
Channel Control FeatureConstant current source and constant voltage source adopt independent double closed loop structure
Channel Control ModeIndependent control
VoltageVoltage Range Per Channel100mV~20V
Minimum discharge voltage2.5V
Accuracy± 0.1% of FS
Constant voltage cutoff current0.06A
Stability± 0.1% of FS
CurrentCurrent Range Per Channel150mA~30A
Accuracy± 0.1% of FS
Stability± 0.1% of FS
PowerPer Channel Output Power600W
Stability± 0.2% of FS
TimeCurrent Response TimeMaximum current rise time 20m S
Step Time Range

≤(365*24 )hour/step,
Time Form Support 00:00:00:000(h, min, s, ms)

Data RecordingRecord ConditionTime△t: 100ms
Voltage△U: 40mV
Current△I: 60mA
Record Frequency10Hz
ChargeCharge ModeConstant current charging, constant voltage charging, constant current and constant voltage charging, constant current and constant voltage of the battery pack, constant power charging
Cutoff ConditionVoltage, current, relative time, capacity, -ΔV
DischargeDischarge ModeConstant current discharge, constant power discharge, constant resistance discharge
Cutoff ConditionVoltage, Current, Relative Time, Capacity, -ΔV
Pulse ModeCharge modeConstant current mode, Constant power mode
Discharge modeConstant current mode constant power mode
Cutoff conditionsTime, line number
Min. pulse width500ms
Number of pulseSingle pulse step supports 32 different pulses
Continuous switching of charge and dischargeA pulsed step can achieve continuous switching from charge to discharge
Cutoff conditionVoltage, relative time
DCIR TestSupports custom point retrieval for DCR calculations
CycleLoop Measure Range1~65535 times
Max Steps Per Loop254
Nested LoopNested loop Function, Max Support 3 Layers
ProtectionSoftware Protection
  • Power-down Data Protection
  • Off-line Testing Function
  • Setting Protection Condition, Setting Parameter: Low Voltage limit, Upper Voltage limit, Low Current limit, Upper Current limit, Delay Time, Single cell difference
Voltage and current detection samplingFour-wire connection
Noise<85dB
Noise<85dB
DatabaseMySQL Database
A Means of Communication of Upper MachineTCP/IP Protocol
Data OutputEXCEL2003/2010, TXT
Communication InterfaceEthernet Port
Per Unit Main Channels No.8
Dimensions12U chamber, W*D*H:600*600*1260(mm)
FixtureTo be determined

Equipment Working Environment:

Project index

Parameter index

Working Temperature Range0℃~40℃
Storage Temperature Range-10℃~50℃
Working Environment Relative Humidity Range≤70% RH (No condensation)
Storage Environment Relative Humidity Range≤80% RH(No condensation)


The number of channels, voltage range, current range and etc. can be customized according client's specific requirements and specimen. Please email or call to Sinuo for further assistance.


















Send your message to this supplier
Send Now

IEC62133-1 20V 30A Battery Testing Equipment For Lithium Ion Battery / Cell Charge Discharge Capacity Test

Ask Latest Price
Brand Name :
Sinuo
Model Number :
SNBT4008FA-20V30A
Certification :
Calibration Certificate (Cost Additional)
Place of Origin :
China
MOQ :
1
Price :
Customized
Contact Supplier
IEC62133-1 20V 30A Battery Testing Equipment For Lithium Ion Battery / Cell Charge Discharge Capacity Test
IEC62133-1 20V 30A Battery Testing Equipment For Lithium Ion Battery / Cell Charge Discharge Capacity Test

Sinuo Testing Equipment Co. , Limited

Verified Supplier
7 Years
guangdong, guangzhou
Business Type :
Manufacturer
Total Annual :
800000-1500000
Employee Number :
30~50
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement