ISO 4892-1-2016 UV Weathering Accelerated Ageing Test Chamber
Product Description
This equipment uses a fluorescent ultraviolet UV lamp to simulate the effect of sunlight, uses condensed moisture to simulate rain and dew, and puts the test material in a cycle program of alternating light and moisture at a certain temperature for testing.
It can detect paint, ink, paint, resin, plastic, rubber, printing and packaging, aluminum profile, adhesive, automobile, motorcycle industry, cosmetics, metal, electronics, electroplating, medicine, etc.
Used to simulate the harm caused by sunlight, rain, and dew.
UV can reproduce the hazards that occur outdoors for months to years in a few days or weeks. The hazard types include: fading, discoloration, loss of gloss, chalking, cracking, turbidity, bubbles, embrittlement, strength decline and oxidation.
The UV weathering accelerated ageing test chamber conforms to standards:
GB/T 14522-93 “Accelerated Weathering Test Method for Plastics, Coatings, Rubber Materials Used for Machinery Industrial Products”
ASTM G154 “Standard Practice for Operating Fluorescent Ultraviolet (UV) Lamp Apparatus for Exposure of Nonmetallic Materials1”
ISO 4892-1-2016 “Plastics-Methods of exposure to laboratory light sources-Part 1: General guidance”
ISO 11507 -2007 “Paints and varnishes - Exposure of coatings to artificial weathering - Exposure to fluorescent UV lamps and water”
ASTMD 4329-2005 “Standard Practice for Fluorescent UV Exposure of Plastic”
Inner Size D×W×H | 450×1170×500 mm | |
External Size D×W×H | 630×1350×1450 mm | |
Control System | Siemens touch screen and PLC controller | |
Main components | Brand ones: Schneider Omron electrical components | |
Light Source | Lamp type | UVA-340 |
Wavelength range | 315nm (its peak value is 340nm) | |
Number of lamps | Total 12 pcs (8 are installed on the chamber, 4 for spares) | |
Lamp power | 40W/pc | |
Lamp brand | Q-lab, American brand | |
Lamp life | Approximately 1600 hours | |
Equipment Function | Temperature, humidity, light, spray, condensation | |
Irradiance monitor: mounted irradiator, 0-5V signal output | ||
Illumination adjustment: dimming system | ||
Parameters
| Temperature range | RT+10℃~70℃ |
Light cycle | 45℃-80℃ | |
Condensing cycle | 40℃-60℃ | |
Humidity range | ≥95%R.H | |
Temperature fluctuation | ≤±0.5℃ | |
Temperature uniformity | ≤±2℃ | |
Temperature resolution | ±0.1℃ | |
Irradiation intensity | 0.3-1.2W/㎡ adjustable | |
Black panel temperature | 40℃~65℃ | |
Distance between lamps | 35mm | |
Distance between Sample and Lamp | 50mm | |
Spray time | 0~999 minutes can be preset on touch screen | |
Test duration | 0~99H59M, can be preset on touch screen | |
Standard test piece | Flat plate type, W75 mm*L150 mm* T max. 1.5mm (Prepared by client according to standard requirements) | |
Numbers of test piece | Approximately 40 pcs Each side of the chamber can hang 20 pieces | |
Condensation (tap water or deionized water) or spray consumption | 8L/day | |
Controller | Siemens control system, can control and monitor the humidity, condensation, water spray, and irradiance on the touch screen. The irradiance can be tested continuously. | |
Power supply | 220V,50HZ, 2.0KW or match client's local power supply requirements | |
Structure and Material | Inner material | SUS304 stainless steel plate |
Outer material | SUS304 stainless steel plate | |
Shape | Tower shape, upper and lower two floors | |
Use Environment | Temperature | 15~35℃ |
Humidity | 50-70 %RH | |
Air pressure | 86~106Kpa | |
1. The ground is level and well ventilated 3. No direct sunlight or other heat source radiation 4. There is no strong air flow. When the surrounding air needs to flow forcibly, the air flow should not be directly blown onto the cabinet; |