IEC 62368-1 Clause 5.4.2, 5.5.8, Annex D Circuit 3 of Table D.1 Surge Test Generator 10KV
Product Information:
This surge test generator conforms to IEC 62368-1:2018 clause 5.4.2, 5.5.8 and Annex D, circuit 3 of Table D.1, Annex G.10, etc., IEC 60950-1:2013 clause 7.4.2, reference 3 of table N.1, IEC60065:2014 clause 10.2, 13.3.4 a).
7-inch touch LCD interface, rich in functions, easy to operate, easy to upgrade software
Intelligent programmable high voltage power supply, built-in high voltage over voltage, over current and short circuit protection
Output intelligent detection, voltage error, no output warning
Technical Parameter:
Applied standard | IEC 62368-1 |
Applied clause | 5.4.2, Circuit 3 of Table D.1, Annex G.10 |
Output voltage | 10kV (Max) ±5% |
Output polarity | Positive, negative, positive and negative cycle |
Input impedance | 1KΩ,±10% |
Storage capacitor | 1000PF |
Charging resistance | 15MΩ |
Impact mode | Automatic or manual |
Impact cycles | 1-9999 |
Impact interval time | 3-999s (3s of which is the inherent charging time of the device) |
Use Environment | Temperature: 15℃-35℃, relative humidity: 10% -75% |
Power source | AC220±10%, 50/60Hz |
Dimension | 470mm×260mm×500mm |
Weight | 30kg |