IEC 60669-1 Clause 12.2.5 Figure 9 Conductor Damage Degree Test Machine
Product Information:
The conductor damage degree test machine is designed and manufactured according to the standard requirements of IEC 60669-1:2017 clause 12.2.5 &12.3.10 figure 9, IEC 60884-1:2013 clause 12.2.5 figure 11, UL486A-B, etc.
This device is use to check whether the terminals with screw and screwless terminals can bears the mechanism force under normal operation. Mainly use to judge whether the design and structure of screw clamping terminals meet the requirement of clamp the conductors without excessive damage. Adopt the structure of guide rail. Can preset test times, while testing, tester will automatically stop when preset test times completed, and output sound alarm signal.
Technical Parameters:
Applied standard | IEC 60669-1 |
Applied clause | 12.2.5, figure 9 |
Test sample | Terminals, connectors |
Test rate | 10±2 RPM |
Diameter of gyration | 75mm (and 76mm for UL standard) |
Test times | 0~9999 |
Weights | 0.3, 0.4, 0.7, 0.9, 1.4, 2kg |
Test height | 260, 280, 300, 320mm |
Diameter of ferrule hole | 6.5, 9.5, 13, 14.5mm |
Power supply | AC220V±10%, 50Hz |