IEC 60309-1 Charging Interface Cable Bending Testing Machine Vehicle Testing Equipment
Product Overview:
Standard: according to IEC62196-1:2014 clause 7.11 and clause 7.15, IEC60309-1:2012 clause 24.4.
Samples and restrictions: Electric vehicle charging interfaces, industrial plugs, sockets and couplers.
Application: Used to test the bending connection part of the "mechanical strength" part of the power connection cable of the charging vehicle plug and socket.
Test principle: The servo motor is used to drive the turntable to drive the work piece to swing left and right, and the machine will automatically stop when the number of times is reached.
Structure and features: The equipment is driven by a servo motor, and large-size specimens are installed on aluminum plates, which can make the swing axis coincide with the point where the cord enters the instrument as much as possible when clamping the specimen, thereby achieving the minimum lateral displacement of the cord and load.
Usage environment: Power supply: AC220V±10%/50-60Hz, power 3KW.
Technical Parameters:
Equipment dimensions | Approx.: W1000*D800*H1600mm | |
Equipment weight | 150kg | |
Test station | Single station | |
Electrical control method | PLC intelligent integrated control, 7-inch human-machine touch interface operation | |
Drive mode | Servo motor drive | |
Specimen clamping method | Mechanical clamping, adjustable clamping point position | |
Bending angle | 0-360° adjustable (default ±45°) | |
Bending rate | 0-60 times/min, can be preset | |
Bending frequency | 0~999999 can be preset, default is 20000 times | |
Load weight | 20N,25N,50N,75N,100N,140N | |
Load power supply | External connection, optional load cabinet with adjustable voltage between conductors 0-250V and adjustable current AC 0-400A | |
Test judgment | Judgment based on the signal given by whether the current is conducting or not |
No. | Fault | Reason | Treatment |
1 | Turn on the POWER switch, but the indicator light not turn on | The external power supply is not connected | Please connect to the external power supply |
The fuse is broken | Find out the reason and change the fuse. | ||
The indicator light damaged | Replace the light | ||
2 | Turn on the POWER switch, Touch screen not work | The internal DC24V power supply is in problem | Replace the DC24V power supply |
Touchscreen damaged | Replace the touchscreen | ||
3 | Touch screen no response | Connection to PLC loose | Reconnect |
Touchscreen damaged | Replace the touchscreen | ||
4 | Load power no power supply | Load socket damaged | Replace the socket |
The fuse is broken | Change the fuse | ||
5 |
Press down Start button, but the fixture do not work. | The display value and preset value of test times are the same | Press Count Cleared |
The E-STOP button is not reset | Release E-STOP button | ||
There is foreign object in the machine, the machinery is stuck | Remove the foreign object | ||
It is not under auto test mode | Press Start button | ||
Connection to motor loosen | Reconnect | ||
Not in starting position | Homing | ||
6 | Motor rotates but the manipulator does not rotate | Check whether the motor output shaft connector is loose | Re-connect |
Check whether the drive belt is broken or too loose | Replace the drive belt | ||
7 | Noise | Swivel speed low or too high | Reset the speed |
Connection to motor loosen | Reconnect |