Specifications
Brand Name :
Sinuo
Model Number :
SN4411-30M-350L
Certification :
Calibration Certificate (Cost Additional)
Place of Origin :
China
MOQ :
1
Price :
Customized
Payment Terms :
T/T
Supply Ability :
10 Sets Per Month
Delivery Time :
30 Days
Packaging Details :
Plywood Case
Pressure range :
0.00—0.3Mpa
Water depth range :
0—30M
Vessel thickness :
3mm
Flange thickness :
20mm
Valve exhaust pressure :
0.35Mpa
Max ultimate pressure :
0.4Mpa
lid opening method :
Cylinder
Control method :
PLC control
Description

IEC 60529 IPX8 Continuous Immersion Test Chamber 350L High Pressure Water Tank

Product overview:

This IPX8 continuous immersion test chamber IEC 60529-2013 “Degrees of protection provided by enclosure (IP code)”. It is used to verify the protective performance of the enclosure for electronic and electrical products, automobiles, motorcycle parts, household appliances, seals and lamps under continuous immersion in water at degree IPX8. By controlling the depth of the sample in the water to achieve a standard equivalent pressure, and simulating water depth pressure by applying a certain pressure of air pressure, to produce water pressure across the entire surface of the specimen enclosure. The water depth range simulation of IPX8 is harsher than IPX7.

Equipment features:

1. The pressure vessel is made of 304 stainless steel, with high-precision overall sub-arc welding and good pressure resistance.

2. The outside of the tank is connected with a transparent tube, and the outer layer is attached with a stainless steel ruler, so that the internal water level can be clearly observed.

3. Special silicone seal ring, good elasticity, not easy to be damaged.

4. The tank lid above the device is fixed with 8 ring screws (distribution auxiliary steel rod).

5. The tester is equipped with safety valve, which automatically releases the pressure when it exceeds the rated pressure to prevent improper operation by the operator and the set pressure is too high

6. Electric control components are imported brands (such as: LS, Panasonic, Omron, etc.); pneumatic components are Airtac brands, to ensure the stability and service life of the equipment.

7. The test time can be set to: 0-999 minutes. When the test time is reached, the pressure can be automatically stopped and the air in the tank can be automatically exhausted. The operator can open the tank lid to take out the test sample.

8. Pressure display: The pressure is displayed by a pressure sensor, and the internal pressure can be automatically stabilized. The control accuracy: ± 0.002Mpa, the sensor display accuracy: 0.001Mpa.

9. 4 Water inlet and drain valves are installed at the bottom of the device.

Technical Parameters:

Model no.:

SN4411-30M-250L

(Optional)

SN4411-30M-350L

SN4411-50M-250L

(Optional)

SN4411-50M-350L

(Optional)

External size Approx. L600*W780*H1750mm Approx. L700*W880*H1750mm Approx. L600*W780*H1750mm Approx. L800*W950*H1750mm
Inner size

φ500mm*1200mm H

φ600mm*1200mm H

φ500mm*1200mm H

φ600mm*1200mm H

Vessel wall thickness 3mm 3mm 4mm 4mm
Vessel material Stainless steel
Flange thickness 20mm 20mm 25mm 25mm
Flange material Stainless steel
Top lid opening method Lifting by cylinder
Equipment weight 120KGS 130KGS 140KGS 150KGS
Pressure control method Auto adjust
Pressure error ±0.002 Mpa
Sensor display accuracy 0.001Mpa
Test water depth range 0—30M 0—30M 0—50M 0—50M
Pressure adjustment range 0.00—0.3Mpa 0.00—0.3Mpa 0.00—0.5Mpa 0.00—0.5Mpa
Safety valve exhaust pressure 0.35Mpa 0.35Mpa 0.55Mpa 0.55Mpa
Maximum ultimate pressure 0.4Mpa 0.4Mpa 0.6Mpa 0.6Mpa
Test time 0-999 min
Power supply terminals for sample

With the terminals for connecting power supply for sample, has 15A bearing capacity. Note: the external power supply device should be prepared by client.

The terminals are showing as following:

IEC 60529 IPX8 Continuous Immersion Test Chamber 350L High Pressure Water Tank

Protection device Pressure safety valve protection, earth leakage switch protection
Pressure adjustment method By setting value of the pressure sensor
Accessories

Auxiliary steel bar *1 PC

Intake pipe *1 PC

Water pipe *1PC (About 5 meter)

Working environment:

*The following working environment should be provided by user

Use site The ground is flat, the drainage is smooth, the floor and wall are waterproofed, and a floor drain or drainage ditch is installed
Ground load capacity is not less than 300kg / m2
Field is well ventilated
No strong vibration around the equipment
No flammable, explosive, corrosive substances and dust around the equipment
Appropriate use and maintenance space is left around the equipment:
Back, left, right, top of the device: 600mm; front of the device: 1000mm
Environment conditions

Temperature:5℃~35℃

Relative humidity:≤85%

Air pressure:86kPa~106kPa

Power supply AC 220V, 50Hz
Water supply Tap water / pure water
Gas source User should prepare the air compressor, the recommended output air pressure: 0.6Mpa—0.8Mpa.

IEC 60529 IPX8 Continuous Immersion Test Chamber 350L High Pressure Water Tank

IEC 60529 IPX8 Continuous Immersion Test Chamber 350L High Pressure Water Tank

IEC 60529 IPX8 Continuous Immersion Test Chamber 350L High Pressure Water Tank

Send your message to this supplier
Send Now

IEC 60529 IPX8 Continuous Immersion Test Chamber 350L High Pressure Water Tank

Ask Latest Price
Watch Video
Brand Name :
Sinuo
Model Number :
SN4411-30M-350L
Certification :
Calibration Certificate (Cost Additional)
Place of Origin :
China
MOQ :
1
Price :
Customized
Contact Supplier
video
IEC 60529 IPX8 Continuous Immersion Test Chamber 350L High Pressure Water Tank
IEC 60529 IPX8 Continuous Immersion Test Chamber 350L High Pressure Water Tank
IEC 60529 IPX8 Continuous Immersion Test Chamber 350L High Pressure Water Tank
IEC 60529 IPX8 Continuous Immersion Test Chamber 350L High Pressure Water Tank

Sinuo Testing Equipment Co. , Limited

Verified Supplier
7 Years
guangdong, guangzhou
Business Type :
Manufacturer
Total Annual :
800000-1500000
Employee Number :
30~50
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement