Specifications
Brand Name :
Skymen
Model Number :
JP-030S
Certification :
CE ROHS FCC SGS
Place of Origin :
China
MOQ :
1 unit
Price :
Negotiation
Supply Ability :
8000 pcs per month
Delivery Time :
In Stock
Packaging Details :
1unit per box
Model :
JP-020S
Capacity :
4.5L
Tank Size :
300*150*100mm
Unit Size :
330*200*235mm
Paking Size :
340*250*310mm
Ultrasonic Power :
90W/180W
Timer :
0-30 minutes adjustable
Frequency :
40KHz
Material :
SUS 304
G.W :
5.4KG
Power Supply :
AC 110V ; AC 220V
Heating power :
200W
Description

Table Top Large Ultrasonic Cleaner Ultrasonic Surgical Instrument Cleaning Bath

Features:

  • Sensitive touch control panel
  • Digital Control display
  • More convenient for operation
  • Stainless steel tank has resistance to wear and long work life.
  • Tank capacity: 4.5L
  • Digital timer, clear digital LCD display
  • With Stainless steel basket
  • Use just tab water, or industrial solvent cleaner for more higher cleaning requirement
  • Industrial control chip microcontroller.flexible circuit boards control, more secure & stable

JP-030S product specification:

Ultrasonic frequency 40,000Hz
Material of tank SUS304
Material of shell SUS304
Capacity 4.5L
Timer Digital control, 0~30 mins
Heater 200W
Power supply type 1 AC 100~120V, 50/60Hz
Power supply type 2 AC 220~240V, 50/60Hz
Ultrasonic power 90W /180W
Tank inner dimension 300*150*100mm
Unit dimension 330*200*235mm
Inner Packing size 340*250*310mm
Transducer 3pcs
N.W. 4.6kg
G.W. 5.4kg
Certificate SGS & CE & RoHS & FCC

How to Use an Ultrasonic Cleaner for Medical & Surgical Instruments


Medical and surgical instruments in a variety of sizes and complexity can pose challenges when it comes to cleaning, disinfecting and sterilizing them after use. An ultrasonic cleaner is an ideal tool for the first step in this three step process to protect medical personnel and patients from possible infection due to pathogens that remain on the instruments after a procedure.

Suggested Ultrasonic Cleaning Procedure

In all cases manufacturers’ instructions should be followed when using an ultrasonic cleaning process. These are representative steps.

Fill the ultrasonic cleaning tank with an approved medical instrument cleaning solution such as CLN-LR012 available from Tovatech following dilution instructions provided. Turn the cleaner on to start the degassing process. This step removes entrained air in new solutions that interferes with the efficiency of cavitation and takes approximately 10 minutes.

In the meantime:

  • Segregate instruments by alloy or composition to avoid potential damage (Chromium plated instruments should not be cleaned ultrasonically)
  • Instruments with movable parts should be disassembled to facilitate cleaning
  • Place the instruments the ultrasonic cleaner’s mesh basket, taking care that they do not come in contact with each other
  • Cannulated or lumened instruments should be positioned to insure interiors are wetted with the cleaning solution. In some instances placing them on an angle will facilitate this
  • Set the control panel per manufacturers’ instructions and start the cleaning process

At the end of the cycle, remove the instruments from the ultrasonic cleaning bath and thoroughly rinse them to remove all traces of the cleaning solution. Deionized water rinses will avoid spotting. If the instruments are not to be immediately disinfected and sterilized be certain that they are thoroughly dried and protected. Part reassembly can occur after sterilization.

Procedures should be in place to guide the replacement of used ultrasonic cleaning solutions. In some instances it is recommended that solution be drained and tanks thoroughly cleaned and dried after each ultrasonic cleaning cycle. Most solutions available today are biodegradable, which facilitates disposal but local authorities should be consulted on proper practices.


The ultrasonic cleaner uses ultrasonic waves (vibration) using water with detergents or enzymatic products to break up soil and organic material on medical instruments/devices. These devices are rinsed then autoclaved (sterilized). The autoclave sterilizer uses heat, steam, and pressure to kill all pathogenic microorganisms and their spores.

Working priciple of Ultrasonic Cleaner

Printing Roller Lab Benchtop Ultrasonic Cleaner 4.5L 180W JP-030S 0-30 Min Adjustable Timer

Package Includes:
1 x Digital Ultrasonic Cleaner
1 x Cleaning Basket
1 x Manual

Printing Roller Lab Benchtop Ultrasonic Cleaner 4.5L 180W JP-030S 0-30 Min Adjustable Timer

Cleaning effect:

Printing Roller Lab Benchtop Ultrasonic Cleaner 4.5L 180W JP-030S 0-30 Min Adjustable TimerPrinting Roller Lab Benchtop Ultrasonic Cleaner 4.5L 180W JP-030S 0-30 Min Adjustable TimerPrinting Roller Lab Benchtop Ultrasonic Cleaner 4.5L 180W JP-030S 0-30 Min Adjustable Timer

Send your message to this supplier
Send Now

Printing Roller Lab Benchtop Ultrasonic Cleaner 4.5L 180W JP-030S 0-30 Min Adjustable Timer

Ask Latest Price
Brand Name :
Skymen
Model Number :
JP-030S
Certification :
CE ROHS FCC SGS
Place of Origin :
China
MOQ :
1 unit
Price :
Negotiation
Contact Supplier
Printing Roller Lab Benchtop Ultrasonic Cleaner 4.5L 180W JP-030S 0-30 Min Adjustable Timer

Skymen Technology Corporation Limited

Verified Supplier
11 Years
guangdong, shenzhen
Since 2007
Business Type :
Manufacturer, Exporter, Seller
Total Annual :
7,000,000-10,000,000
Employee Number :
300~500