Specifications
Brand Name :
CHX
Model Number :
CHX-DM013
Certification :
CE, RoHS
Place of Origin :
CHINA
MOQ :
10pc
Price :
Negotiation
Payment Terms :
T/T, Western Union,Paypal,L/C
Supply Ability :
50000pcs/month
Delivery Time :
5-35days
Packaging Details :
1pcs/gift box, 30~50pcs/ctn; package size: 10X5X3cm; gross weight:0.500kg
Model :
CHX-DM013
DC voltage :
6V/60V/600V/1000V
AC voltage :
6V/60V/600V/750V
AC Current :
600uA/6000uA/60mA/600mA/6A/10A
Storage Temperature :
-10~50℃
Gross Weight :
0.700kg
Description

LCD Digital Temperature and Humidity Meter Hygrothermograph Thermometer

Description:

The instrument performance is stable, the quality of reliability is 3 5/6 digital multimeter, using LCD display, clear reading, intuitive display, easy to operate, can be used to measure the DC voltage, AC voltage sine wave RMS, DC current, AC current sine wave True RMS, resistance, capacitance, frequency, duty cycle, diode, on-off test. As well as unit symbol display, data retention, automatic power and other functions. The machine uses a high-performance MCU processor, with a high cost, the instrument is fully functional, high accuracy, easy to use, is the laboratory, factories, radio enthusiasts and the ideal home tools.

Preparation


1.1.1 When using the instrument, the user must comply with the standard safety rules:
- Universal anti-shock protection
- Prevent misuse of instruments
1.1.2 After receiving the instrument, check if it is damaged during transport.
1.1.3 in the rough conditions of preservation, shipment, check and confirm whether the instrument is damaged.
1.1.4 The pen must be in good condition. Before use, check whether the insulation of the test leads is damaged and the wires of the wires are

exposed.
1.1.5 Use the table provided with the table to ensure safety, if necessary, must use the same or the same level of the pen to replace.

1.2 Use


1.2.1 When using, you must use the correct function and range.
1.2.2 Do not exceed the protection range of each range to measure the value.
1.2.3 Do not touch the top of the test leads (metal parts) when the meter is connected to the measuring circuit.
1.2.4 In the measurement, if the measured voltage is higher than 60V DC or 30V AC (RMS), should pay attention to keep the fingers always in the table after the finger care device.
1.2.5 Do not measure the voltage when the voltage between the measuring end and the earth exceeds AC 600V.
1.2.6 Before turning the change switch to change the measuring function, remove the test leads from the circuit under test.
1.2.7 Do not live measurement resistance, capacitance, diode and test circuit off.
1.2.8 In the current, resistance, capacitance, diode and line continuity test range, care should be taken to avoid connecting the meter to the voltage source.
1.2.9 Do not measure the capacitance until the capacitor is fully discharged.
1.2.10 Do not use this instrument near explosive gas, steam or dust.
1.2.11 If you notice any abnormality or malfunction of the instrument, stop using it.
1.2.12 Do not use the instrument unless the instrument case and battery cover are fully fastened in place.
1.2.13 Do not store or use the instrument in direct sunlight, high temperature, high humidity.

3.2 Technical indicators

Ambient temperature: 23 ± 5 ℃ Relative humidity: <75%

3.2.1 True rms zero input

3.2.1.1 The measurement of sine wave signal, the use of true RMS measurement method than the traditional average response method error is small.

3.2.1.2 True RMS The instrument can accurately measure the sine wave signal, but if it is on the AC function, the instrument may display 1 to 50 if the measured signal is not input (shorted at the AC voltage range and the input terminal) Word between a reading. These deviations are normal. Within the specified measuring range, they do not affect the accuracy of the multimeter to measure alternating current.

3.2.1.3 True RMS requires that the input signal reach a certain level for measurement. Therefore, the AC voltage and current range is specified between 2% and 100% of full scale.

3.2.2 DC voltage

Range Resolution Accuracy
6V 0.001V ±(0.5% of reading + 5 words)
60V 0.01V
600V 0.1V ±(0.8% of reading + 5 words)

- Input impedance: 10MΩ

- Maximum input voltage: 600V DC or 600V AC (rms)

Note:

In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,

This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.

3.2.3 AC voltage

Range Resolution Accuracy
6V 0.001V ±(0.8% of reading + 3words)
60V 0.01V
600V 0.1V ±(1.0% of reading + 10words)

- Input impedance: 10MΩ

- Maximum input voltage: 600V AC (RMS) or 600V DC

- Frequency range: 40 ~ 1000Hz True RMS

Note:

In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,

This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.

3.2.4 Alternating current

Range Resolution Accuracy
600.0uA 0.1uA ±(1.5% of reading +10words)
6000uA 1uA
60.00mA 0.01mA
600.0mA 0.1mA
6A 0.001A ±(2.5% of reading +10words)
10A 0.01A

- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)

10A range without insurance

- Maximum input current: mA: 600mA DC or AC rms;

10A: 10A DC or AC rms;

When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.

- Frequency response: 40Hz ~ 1000Hz True RMS.

3.2.5 DC

Range Resolution Accuracy
600.0uA 0.1uA ±(1.0% of reading +5words)
6000uA 1uA
60.00mA 0.01mA
600.0mA 0.1mA
6A 0.001A ±(2.0% of reading +10words)
10A 0.01A

- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)

10A range without insurance

- Maximum input current: mA: 600mA DC or AC rms;

10A: 10A DC or AC rms;

When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.

3.2.6 Frequency

Range Resolution Accuracy
9.999Hz 0.001Hz ±(1.0% of reading +3words)
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 0.001kHz
99.99KHZ 0.01kHZ
999.9KHZ 0.1KHZ
9.999MHZ 0.001MHZ

- Overload protection: 250V DC or AC (rms)

- Input voltage range: 600mV ~ 10V AC (with the measured frequency increases, the input voltage should also increase)

3.2.7 Duty cycle

Range Resolution Accuracy
0.1 – 99.9% 0.1% ± 3.0%

- Frequency response: 10 ~ 10MHz

- Input voltage range: 600mV ~ 10VAC (with the measured frequency increases, the input voltage should also increase)

- Maximum input voltage: 250V AC (rms)

3.2.8 Resistance

Range Resolution Accuracy
600W 0.1W ±(0.8% of reading +3words)
6kW 0.001kW
60kW 0.01kW
600kW 0.1kW
6MW 0.001MW ±(1.2% of reading +3words)
60MW 0.01MW

- Open circuit voltage: approx. 1.0V

- Overload protection: 250V DC or AC (rms)

Send your message to this supplier
Send Now

750V Handheld Digital Multimeter Universal Anti Shock Protection

Ask Latest Price
Brand Name :
CHX
Model Number :
CHX-DM013
Certification :
CE, RoHS
Place of Origin :
CHINA
MOQ :
10pc
Price :
Negotiation
Contact Supplier
750V Handheld Digital Multimeter Universal Anti Shock Protection
750V Handheld Digital Multimeter Universal Anti Shock Protection