1999 Display Digital Clamp Multimeter Voltage Tester 400A AC
Specifications
The instrument shall specify the period of one year,during in 18℃ ~ 28℃,The relative humidity is less than 75% under the conditions of re calibration.
3.1 Overview
Automatic measurement and manual measurement
Overload protection¥The maximum voltage allowed between the measuring terminal and earth:600V DC or 600V AC
Display:LCD
Maximum:1999 display
Polar indication:Automatic indicator,‘-’,Display negative
Over range display:‘0L’ or ‘-0L’.
Sampling time: about 3 times / sec
Display unit and power display
Automatic power off:15Minutes
Open Jaw is 25mm; test Line OD less than23mm
Battery type:1.5V AAA
Battery voltage indication:LCD Symbol
Temperature coefficient:less 0.1
operating temperature:18℃ ~ 28℃
Storage temperature:-10℃ ~ 50℃
Size:184.0×66.0×32.5mm
Weight:about 190g (Including battery)
3.2 Technical indicators
Environment temperature:23±5℃ Relative humidity:<75%
3.2.1 AC Current
Range | Resolution | Accuracy |
2A | 0.001A | ±(4.0% + 20) |
20A | 0.01A | ±(2.5% + 8) |
200A | 0.1A | |
400A | 1.0A |
- Max input:400A AC
- Frequency:50Hz
- When ac current is measured, the meter automatically opens an internal low-pass filter to filter out high-frequency current.
3.2.2 DC voltage
Range | Resolution | Accuracy |
2V | 0.001V | ±(0.8% + 5) |
20V | 0.01V | |
200V | 0.1V | |
600V | 0.1V | ±(1.0% + 5) |
- Input impedance:10MW
- Maximum/ input voltage:600V AC (Effective value)OR 600V DC
3.2.4 AC voltage
Range | Resolution | Accuracy |
2V | 0.001V | ±(1.2% + 5) |
20V | 0.01V | |
200V | 0.1V | |
600V | 0.1V | ±(1.5% + 5) |
- Input impedance:10MW
- Maximum/ input voltage:600V AC (Effective value)or 600V DC
In the small voltage range, the meter pen is not connected to the measured circuit, the meter may have jumping reading, this is normal, because of the high sensitivity of the meter, does not affect the actual measurement results
3.2.5 Frequency (Voltage frequency measurement)
Range | Resolution | Accuracy |
9.999Hz | 0.001Hz |
±(0.3% + 5)
|
99.99Hz | 0.01Hz | |
999.9Hz | 0.1Hz | |
9.999kHz | 0.001kHz | |
99.99KHZ | 0.01kHZ |
- Overload protection:600V DC or AC(Effective value)
3.2.6 Resistance
Range | Resolution | Accuracy |
200W | 0.1W | ±(0.8% + 3) |
2kW | 0.001kW | |
20kW | 0.01kW | |
200kW | 0.1kW | |
2MW | 0.001MW | ±(1.2% + 3) |
20MW | 0.1MW |
- open-circuit voltage:About 0.4V
- Overload protection:600V DC or AC(Effective value)
3.2.7 Continuity test
Range | Resolution | Function |
0. 1W | If the measured line resistance is less than 50, enclosing the instrument may sound a buzzer |
- Overload protection:600V DC or AC(Effective value)
3.2.8 Capacitance
Range | Resolution | Accuracy |
9.999nF | 0.001nF | |
99.99nF | 0.01nF | |
999.9nF | 0.1nF | |
9.999mF | 0.001mF | |
99.99mF | 0.01mF | ±(3.0% + 5) |
999.9mF | 0.1mF | |
9.999mF | 0.001mF | ±(5.0% + 5) |
99.99mF | 0.01mF | Not define |
- Overload protection:250V DC or AC(Effective value)