Specifications
Brand Name :
Radarking
Model Number :
RDK-PQI-2
Certification :
IS09001; IS014001
Place of Origin :
Made in China
MOQ :
5pcs
Payment Terms :
Western Union, T/T, L/C
Delivery Time :
35days
Packaging Details :
Paper box package
communication :
TCP/IP, RS232/485 and etc
Standard :
IEC-103
Channels :
A、B、C phase voltage A、B、C phase current
Measurement Range :
Voltage 0~100V ,220V.380V(customized) Current 0~6A
Harmonics Error :
Class A
Dimension :
252×182×290mm
name :
power quality monitoring system
Description

High Efficient Power Quality Monitoring Equipment of Measuring Power Grid Current Voltage

According to the fast development in economic, power load becomes larger and larger day by day, especial the growing impact no-linear load, which cause the waveform distortion, voltage deviation, flickering, unbalance in 3 phase and such power quality problems in power grid. RDK-PQI-2 power quality monitor is popular with users in power, metallurgy, railway system based on its high accuracy, full function and easy operation. It is suit for 500KV, 220KV, 110KV and 35KV transformer substation, kinds of power station and big consumers in power. Meanwhile, it is also suit for 10KV income line power users. It meets international standard.

Features:

1. Parameter measurement in stable state

It measures power grid frequency, frequency deviation, voltage deviation, true RMS in voltage and current, RMS of fundamental wave, voltage, current harmonics(2-50 times), inter harmonics, unbalance in three phase voltage current, voltage fluctuation and flickering, voltage current positive sequence, negative sequence, zero sequence, voltage current initial phase, apparent power, active power, reactive power, power factor.

2. Parameter measurement in transient state

It measures voltage swell, sag, interruption, records wave under certain event. And wave recording can be set to manual trigger or automatic trigger.

3. Harmonic constraints protection, offers contact on warning, relay tripping.

4. Support for multi communication as TCP/IP, RS232/485 and etc, meets with IEC-103.

Specification:

Item

Parameter

Channels

A,B,C phase voltage A,B,C phase current

Measurement Range

Voltage 0~100V ,220V.380V(customized). Current 0~6A

Frequency Measurement Error

≤0.01Hz

Harmonics Error

Class A

Inter-Harmonics Error

Same as harmonics

Voltage Deviation Error

≤0.2%

3 Phase Unbalance Error

≤0.2%

Current Asymmetry Factor

≤0.2%

Flickering Error

Pst≤5% Plt≤5%

Fluctuating Error

≤0.5%

Phase Angel Error

≤0.2º

Power Error

≤0.5%

Event Wave Recording

5 cycles before event, 5 cycles after event

Display

320×240mm LCD

Power Supply

AC 220V±20% Frequency 45Hz~55Hz DC 220V±20%

Consumption

≤10VA

Environment Temperature

-25℃~75℃

Relative Humidity

0~90% non-condensing

Size

252×182×290mm

Weight

2.5Kg

Send your message to this supplier
Send Now

High Efficient Power Quality Monitoring Equipment For Measuring Power Grid Current Voltage

Ask Latest Price
Brand Name :
Radarking
Model Number :
RDK-PQI-2
Certification :
IS09001; IS014001
Place of Origin :
Made in China
MOQ :
5pcs
Payment Terms :
Western Union, T/T, L/C
Contact Supplier
High Efficient Power Quality Monitoring Equipment For Measuring Power Grid Current Voltage

WUHAN RADARKING ELECTRONICS CORP.

Active Member
9 Years
hubei, wuhan
Since 2002
Business Type :
Manufacturer, Exporter, Seller
Total Annual :
10000000-15000000
Employee Number :
100~200
Certification Level :
Active Member
Contact Supplier
Submit Requirement