Engineered plans | Based on AS/NZS 4600 standard engineering plan | |||||||
Wall Frames | All exterior and interior 89mm*41mm thickness from 0.75mm to 1.15mm based on design | |||||||
Roof Framing | Australia standard Engineered roof trusses 89mm*41mm, thickness from 0.75mm to 1.15mm | |||||||
Fascia | Steel fascia board 200mm*25mm | |||||||
Roofing | either high tensile corrugated roofing sheet or asphalt roofing tile | |||||||
Soffits | fiber cement board | |||||||
Cladding | colorbond cladding | |||||||
Guttering | Steel gutter with stainless steel downpipe | |||||||
Windows | Australia standard alum. Power coated Profile and glass, glazed windows | |||||||
Front Entry Door | Australia standard alum. Power coated Profile and glass, glazed Door | |||||||
Ceiling Batten | Deepblue 22 batten for ceiling | |||||||
Insulation | R2.5 Glass wool to the wall, R3.5 Glass wool to ceiling | |||||||
Interior linings | gypsum board for ceiling | |||||||
gypsum board+ engineering interior wall panel | ||||||||
Scotia | PVC scotia mold | |||||||
Skirting | 80mm PVC Skirting | |||||||
Shelving | laminated Plywood with rail to rob, | |||||||
Interior Doors | flat MDF panel door | |||||||
Door Hardware | hinges, locks, key all included | |||||||
Kitchen | Optional | |||||||
Toilets | Water-Mark Toilet | |||||||
Tapware | Australia standard | |||||||
Laundry Tub (if have) | optional | |||||||
Showers (if have) | 900/1000 acrylic wall with safety glass doors | |||||||
Bath (if have) | optional | |||||||
Slide shower (if have) | 900/1000 | |||||||
Vanities (if have) | optional | |||||||
Hot water Cylinder | optional | |||||||
A/C | optional | |||||||
Appliances | optional |
Why Choose Light Gauge Steel Structure?
1)Lifetime for structure: 100 years.
2)Earthquake resistance: mix more than 8 grades.
3)Wind resistance:max 60m/s.
4)Fire resistance: all the materials used can be fire resistance.
5)Snow resistance: max 2.9KN/m²as required
6)Heat insulation:100 mm in thickness can match 1 m thickness of the brick wall.
7)High acoustic insulation:60db of exterior wall 40db of interior wall
8)Insect prevention: Free from the damages by insects, such as white ants
9)Ventilation: a combination of natural ventilation or air supply keep the indoor air fresh and clean
10)Packing and delivery: 140SQM/ 40'HQ container for structure only and 90SQM/ 40'HQ container for structure with decorating materials.
11)Installation: the average is one worker one day install one SQM.
12)Installation guide: dispatch engineer to guide on site.
Production in DeepBlue factory:
Your first choice, Deepblue Smarthouse the best Prefabricated house in China.